Details
   web
Records
Author Aksaev, E. E.; Gershenzon, E. M.; Gershenson, M. E.; Goltsman, G. N.; Semenov, A. D.; Sergeev, A. V.
Title Prospects for using high-temperature superconductors to create electron bolometers Type Journal Article
Year 1989 Publication Pisma v Zhurnal Tekhnicheskoi Fiziki Abbreviated Journal (up) Pisma v Zhurnal Tekhnicheskoi Fiziki
Volume 15 Issue 14 Pages 88-93
Keywords HTS HEB
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0320-0116 ISBN Medium
Area Expedition Conference
Notes Перспективы применения высокотемпературных сверхпроводников для создания электронных болометров Approved no
Call Number Serial 1693
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gershenson, M. E.; Goltsman, G. N.; Karasik, B. S.; Lyulkin, A. M.; Semenov, A. D.
Title Fast-response superconducting electron bolometer Type Journal Article
Year 1989 Publication Pisma v Zhurnal Tekhnicheskoi Fiziki Abbreviated Journal (up) Pisma v Zhurnal Tekhnicheskoi Fiziki
Volume 15 Issue 3 Pages 88-92
Keywords Nb HEB
Abstract The general design, operation, and performance characteristics of fast-response electronic bolometers using a thin superconducting Nb film on a leucosapphire substrate are briefly reviewed. The volt-watt sensitivity of the bolometrs is 2,000-200,000 V/W, the operating temperature is 1.6 K, and the time constant is 4-4.5 ns.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1694
Permanent link to this record
 

 
Author Gershenzon, E. M.; Gurvich, Y. A.; Orlova, S. L.; Ptitsina, N. G.
Title Scattering of electrons by charged impurities in Ge under cyclotron resonance conditions Type Journal Article
Year 1976 Publication Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников Abbreviated Journal (up) Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников
Volume 10 Issue Pages 1379-1383
Keywords Ge, cyclotron resonance, charged impurities,
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1772
Permanent link to this record
 

 
Author Bondarenko, O. I.; Gershenzon, E. M.; Gurvich, Y. A.; Orlova, S. L.; Ptitsina, N. G.
Title Measurement of the width of the cyclotron resonance line of n-type Ge in quantizing magnetic fields Type Journal Article
Year 1972 Publication Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников Abbreviated Journal (up) Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников
Volume 6 Issue Pages 362-363
Keywords Ge, cyclotron resonance, quantizing magnetic fields
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1774
Permanent link to this record
 

 
Author Aksaev, E. E.; Gershenzon, E.M.; Gol'tsman, G. N.; Mirskij, G. I.; Semenov, A. D.
Title Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution Type Journal Article
Year 1991 Publication Pribory i Tekhnika Eksperimenta Abbreviated Journal (up) Pribory i Tekhnika Eksperimenta
Volume 34 Issue 2 Pages 125-131
Keywords BWO, applications
Abstract The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0032-8162 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1683
Permanent link to this record