|
Elezov, M. S., Ozhegov, R. V., Goltsman, G. N., & Makarov, V. (2017). Development of the experimental setup for investigation of latching of superconducting single-photon detector caused by blinding attack on the quantum key distribution system. In EPJ Web of Conferences (Vol. 132, 2).
Abstract: Recently bright-light control of the SSPD has been
demonstrated. This attack employed a “backdoor†in the detector biasing
scheme. Under bright-light illumination, SSPD becomes resistive and
remains “latched†in the resistive state even when the light is switched off.
While the SSPD is latched, Eve can simulate SSPD single-photon response
by sending strong light pulses, thus deceiving Bob. We developed the
experimental setup for investigation of a dependence on latching threshold
of SSPD on optical pulse length and peak power. By knowing latching
threshold it is possible to understand essential requirements for
development countermeasures against blinding attack on quantum key
distribution system with SSPDs.
|
|
|
Goltsman, G. N., Samartsev, V. V., Vinogradov, E. A., Naumov, A. V., & Karimullin, K. R. (2015). New generation of superconducting nanowire single-photon detectors. In EPJ Web of Conferences (Vol. 103, 01006 (1 to 2)).
Abstract: We present an overview of recent results for new generation of infrared and optical superconducting nanowire single-photon detectors (SNSPDs) that has already demonstrated a performance that makes them devices-of-choice for many applications. SNSPDs provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, SNSPDs are also compatible with an integrated optical platform as a crucial requirement for applications in emerging quantum photonic technologies. By embedding SNSPDs in nanophotonic circuits we realize waveguide integrated single photon detectors which unite all desirable detector properties in a single device.
|
|
|
Florya, I. N., Korneeva, Y. P., Sidorova, M. V., Golikov, A. D., Gaiduchenko, I. A., Fedorov, G. E., et al. (2015). Energy relaxtation and hot spot formation in superconducting single photon detectors SSPDs. In EPJ Web of Conferences (Vol. 103, 10004 (1 to 2)).
Abstract: We have studied the mechanism of energy relaxation and resistive state formation after absorption of a single photon for different wavelengths and materials of single photon detectors. Our results are in good agreement with the hot spot model.
|
|
|
Fedorov, G. E., Gaiduchenko, I. A., Golikov, A. D., Rybin, M. G., Obraztsova, E. D., Voronov, B. M., et al. (2015). Response of graphene based gated nanodevices exposed to THz radiation. In EPJ Web of Conferences (Vol. 103, 10003 (1 to 2)).
Abstract: In this work we report on the response of asymmetric graphene based devices to subterahertz and terahertz radiation. Our devices are made in a configuration of a field-effect transistor with conduction channel between the source and drain electrodes formed with a CVD-grown graphene. The radiation is coupled through a spiral antenna to source and top gate electrodes. Room temperature responsivity of our devices is close to the values that are attractive for commercial applications. Further optimization of the device configuration may result in appearance of novel terahertz radiation detectors.
|
|
|
Hübers, H. - W., Semenov, A., Richter, H., Birk, M., Krocka, M., Mair, U., et al. (2002). Terahertz Heterodyn Receiver with a hot-electron bolometer mixer. In U. Wolf, J. Farhoomand, & C. R. McCreight (Eds.), Far-IR, Sub-mm & MM Detector Technology Workshop (pp. 3–24). NASA CP. NASA.
Abstract: During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA) [1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR.
|
|
|
Semenov, A., Hübers, H. - W., Engel, A., & Gol’tsman, G. (2002). Superconducting quantum detector for far infrared astronomy. In J. Wolf, J. Farhoomand, & C. R. McCreight (Eds.), Far-IR, Sub-mm & MM Detector Technology Workshop (pp. 3–49). NASA CP. NASA.
Abstract: We present the concept of the superconducting quantum detector for astronomy. Response to a single absorbed photon appears due to successive formation of a normal spot and phase-slip-centres in a narrow strip carrying sub-critical supercurrent. The detector simultaneously has a moderate energy resolution and a variable cut-off wavelength depending on both the material used and operation conditions. We simulated performance of the background-limited direct detector having the 100-micrometer cut-off wavelength. Low dark count rate will allow to realise 10-21 W Hz-1/2 noise equivalent power at 4 K background radiation. The detection mechanism provides a moderate 1/20 energy resolution at 50-micrometer wavelength.
|
|
|
Tiulina, V., Iomdina, E., Goltsman, G., Seliverstov, S., Sianosyan, A., Teplyakova, K., et al. (2019). UVB promotes the initiation of uveitic inflammatory and changes in thehydration of the cornea in vivo (Vol. 9).
Abstract: Recently, active research has been conducted in the field of terahertz (THz) scanning of human tissues for noninvasive determination of their hydration level, which haves hown high diagnostic efficiency of this technology in various pathological conditions. Recently, we have developed a laboratory model of the facility for monitoring the state of the water balance of the cornea using THz scanning in vivo, which opens up the possibility of applying this approach in ophthalmology. The aim of the work wasto compare the results of the THz scan of the cornea with its clinical changes using the example of an experimental model of the UV induced keratouveitis. Anexperimental study, which included a comprehensive assessment of clinical changes in the cornea of rabbits during keratouveitis induction, revealed a decrease in the stability of the tear film, pathological changes in the corneal epithelium and stroma, as well as its anatomical and optical parameters. Comparison of data obtained in the THz scan of the cornea with tears production, optical coherence tomography and confocal microscopy showed their consistency in all observation periods, which allows us to conclude that the developed laboratory setup works and the feasibility of further research to promote the corneal hydration evaluation technology in clinical practice. Acknowledgements: Research was funded by the RSF, grant number 161500255.
|
|
|
Minaeva, O., Fraine, A., Korneev, A., Divochiy, A., Goltsman, G., & Sergienko, A. (2012). High resolution optical time-domain reflectometry using superconducting single-photon detectors. In Frontiers in Opt. 2012/Laser Sci. XXVIII (Fw3a.39). Optical Society of America.
Abstract: We discuss the advantages and limitations of single-photon optical time-domain reflectometry with superconducting single-photon detectors. The higher two-point resolution can be achieved due to superior timing performance of SSPDs in comparison with InGaAs APDs.
|
|
|
Matyushkin, Y., Fedorov, G., Moskotin, M., Danilov, S., Ganichev, S., & Goltsman, G. (2020). Gate-mediated helicity sensitive detectors of terahertz radiation with graphene-based field effect transistors. In Graphene and 2dm Virt. Conf..
Abstract: Closing of the so-called terahertz gap results in an increased demand for optoelectronic devices operating in the frequency range from 0.1 to 10 THz. Active plasmonic in field effect devices based on high-mobility two-dimensional electron gas (2DEG) opens up opportunities for creation of on-chip spectrum [1] and polarization [2] analysers. Here we show that single layer graphene (SLG) grown using CVD method can be used for an all-electric helicity sensitive polarization broad analyser of THz radiation. Allourresults show plasmonic nature of response. Devices are made in a configuration ofa field-effect transistor (FET) with a graphene channel that has a length of 2 mkm and a width of 5.5 mkm. Response of opposite polarity to clockwise and anticlockwise polarized radiation is due to special antenna design (see Fig.1c) as follow works [2,3]. Our approaches can be extrapolated to other 2D materials and used as a tool to characterize plasmonic excitations in them. [1]Bandurin, D. A., etal.,Nature Communications, 9(1),(2018),1-8.[2]Drexler, C.,etal.,Journal of Applied Physics, 111(12),(2012),124504.[3]Gorbenko, I. V.,et al.,physica status solidi (RRL)–Rapid Research Letters, 13(3),(2019),1800464.
|
|
|
Tong, C. - Y. E., Meledin, D., Loudkov, D., Blundell, R., Erickson, N., Kawamura, J., et al. (2003). A 1.5 THz Hot-Electron Bolometer mixer operated by a planar diode based local oscillator. In IEEE MTT-S Int. Microwave Symp. Digest (Vol. 2, pp. 751–754).
Abstract: We have developed a 1.5 THz superconducting NbN Hot-Electron Bolometer mixer. It is operated by an all-solid-state Local Oscillator comprising of a cascade of 4 planar doublers following an MMIC based W-band power amplifier. The threshold available pump power is estimated to be 1 /spl mu/W.
|
|