Semenov, A. D., Hübers, H. - W., Gol’tsman, G. N., & Smirnov, K. (2002). Superconducting quantum detector for astronomy and X-ray spectroscopy. In J. Pekola, B. Ruggiero, & P. Silvestrini (Eds.), Proc. Int. Workshop on Supercond. Nano-Electronics Devices (pp. 201–210). Boston, MA: Springer.
Abstract: We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array.
|
Gershenzon, E. M., Gol’tsman, G. N., Sergeev, A., & Semenov, A. D. (1990). Picosecond response of YBaCuO films to electromagnetic radiation. In W. Gorzkowski, M. Gutowski, A. Reich, & H. Szymczak (Eds.), Proc. European Conf. High-Tc Thin Films and Single Crystals (pp. 457–462).
Abstract: Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized.
|
Blundell, R., Kawamura, J. H., Tong, C. E., Papa, D. C., Hunter, T. R., Gol’tsman, G. N., et al. (1998). A hot-electron bolometer mixer receiver for the 680-830 GHz frequency range. In Proc. 6-th Int. Conf. Terahertz Electron. (pp. 18–20). IEEE.
Abstract: We describe a heterodyne receiver designed to operate in the partially transparent atmospheric windows centered on 680 and 830 GHz. The receiver incorporates a niobium nitride thin film, cooled to 4.2 K, as the phonon-cooled hot-electron mixer element. The double sideband receiver noise, measured over the frequency range 680-830 GHz, is typically 700-1300 K. The instantaneous output bandwidth of the receiver is 600 MHz. This receiver has recently been used at the SubMillimeter Telescope, jointly operated by the Steward Observatory and the Max Planck Institute for Radioastronomy, for observations of the neutral carbon and CO spectral lines at 810 GHz and at 806 and 691 GHz respectively. Laboratory measurements on a second mixer in the same test receiver have yielded extended high frequency performance to 1 THz.
|
Yagoubov, P., Kroug, M., Merkel, H., Kollberg, E., Schubert, J., Hubers, H. - W., et al. (1998). Performance of NbN phonon-cooled hot-electron bolometric mixer at Terahertz frequencies. In Proc. 6-th Int. Conf. Terahertz Electron. (pp. 149–152).
Abstract: The performance of a NbN based phonon-cooled Hot Electron Bolometric (HEB) quasioptical mixer is investigated in the 0.65-3.12 THz frequency range. The device is made from a 3 nm thick NbN film on high resistivity Si and integrated with a planar spiral antenna on the same substrate. The in-plane dimensions of the bolometer strip are 0.2/spl times/2 /spl mu/m. The results of the DSB noire temperature are: 1300 K at 650 GHz, 4700 K at 2.5 TBz and 10000 K at 3.12 THz. The RF bandwidth of the receiver is at least 2.5 THz. The amount of LO power absorbed in the bolometer is about 100 nW. The mixer is linear to within 1 dB compression up to the signal level 10 dB below that of the LO. The intrinsic single sideband conversion gain is measured to be -9 dB, the total conversion gain -14 dB.
|
Maslennikov, S. N., Morozov, D. V., Ozhegov, R. V., Smirnov, K. V., Okunev, O. V., & Gol’tsman, G. N. (2004). Imaging system for submillimeter wave range based on AlGaAs/GaAs hot electron bolometer mixers. In Proc. 5-th MSMW (Vol. 2, pp. 558–560).
Abstract: Electromagnetic radiation of the submillimeter (SMM) range is dispersed and absorbed significantly less than infrared (IR) radiation when passing through different objects. That is the reason for the development of an SMM imaging system. In this paper, we discuss the design of an SMM heterodyne imager, based on a matrix of AlGaAs/GaAs heterostructure hot electron bolometer mixers (HEB) with relatively high (about 77 K) operating temperature. The predicted double side band (DSB) noise temperature is about 1000 K and optimal local oscillator (LO) power is about 1 /spl mu/W for such mixers, which seems to be quite prospective for an SMM heterodyne imager.
|