Ryabchun, S., Tong, C. - Y. E., Blundell, R., & Gol'tsman, G. (2009). Stabilization scheme for hot-electron bolometer receivers using microwave radiation. IEEE Trans. Appl. Supercond., 19(1), 14–19.
Abstract: We present the results of a stabilization scheme for terahertz receivers based on NbN hot-electron bolometer (HEB) mixers that uses microwave radiation with a frequency much lower than the gap frequency of NbN to compensate for mixer current fluctuations. A feedback control loop, which actively controls the power level of the injected microwave radiation, has successfully been implemented to stabilize the operating point of the HEB mixer. This allows us to increase the receiver Allan time to 10 s and also improve the temperature resolution of the receiver by about 30% in the total power mode of operation.
|
Ryabchun, S., Tong, C. - Y. E., Paine, S., Lobanov, Y., Blundell, R., & Goltsman, G. (2009). Temperature resolution of an HEB receiver at 810 GHz. IEEE Trans. Appl. Supercond., 19(3), 293–296.
Abstract: We present the results of direct measurements of the temperature resolution of an HEB receiver operating at 810 GHz, in both continuum and spectroscopic modes. In the continuum mode, the input of the receiver was switched between black bodies with different physical temperatures. With a system noise temperature of around 1100 K, the receiver was able to resolve loads which differed in temperature by about 1 K over an integration time of 5 seconds. This resolution is significantly worse than the value of 0.07 K given by the radiometer equation. In the spectroscopic mode, a gas cell filled with carbonyl sulphide (OCS) gas was used and the emission line at 813.3537060 GHz was measured using the receiver in conjunction with a digital spectrometer. From the observed spectra, we determined that the measurement uncertainty of the equivalent emission temperature was 2.8 K for an integration time of 0.25 seconds and a spectral resolution of 12 MHz, compared to a 1.4 K temperature resolution given by the radiometer equation. This relative improvement is due to the fact that at short integration times the contribution from 1/f noise and drift are less dominant. In both modes, the temperature resolution was improved by about 40% with the use of a feedback loop which adjusted the level of an injected microwave radiation to maintain a constant operating current of the HEB mixer. This stabilization scheme has proved to be very effective to keep the temperature resolution of the HEB receiver to close to the theoretical value given by the radiometer equation.
|
Driessen, E. F. C. (2009). Coupling light to periodic nanostructures. Fac. Scien., Leiden Un., , 144.
|
Wild, W., Kardashev, N. S., Likhachev, S. F., Babakin, N. G., Arkhipov, V. Y., Vinogradov, I. S., et al. (2009). Millimetron—a large Russian-European submillimeter space observatory. Exp. Astron., 23(1), 221–244.
Abstract: Millimetron is a Russian-led 12 m diameter submillimeter and far-infrared space observatory which is included in the Space Plan of the Russian Federation for launch around 2017. With its large collecting area and state-of-the-art receivers, it will enable unique science and allow at least one order of magnitude improvement with respect to the Herschel Space Observatory. Millimetron will be operated in two basic observing modes: as a single-dish observatory, and as an element of a ground-space very long baseline interferometry (VLBI) system. As single-dish, angular resolutions on the order of 3 to 12 arc sec will be achieved and spectral resolutions of up to a million employing heterodyne techniques. As VLBI antenna, the chosen elliptical orbit will provide extremely large VLBI baselines (beyond 300,000 km) resulting in micro-arc second angular resolution.
|
Parrott, E. P. J., Zeitler, J. A., Fris<cc><152>c<cc><152>ic<cc><81>, T., Pepper, M., Jones, W., Day, G. M., et al. (2009). Testing the sensitivity of terahertz spectroscopy to changes in molecular and supramolecular structure: a study of structurally similar cocrystals. Crystal Growth & Design, 9(3), 1452–1460.
Abstract: Terahertz time-domain-spectroscopy (THz-TDS) has emerged as a versatile spectroscopic technique, and an alternative to powder X-ray diffraction in the characterization of molecular crystals. We tested the ability of terahertz spectroscopy to distinguish between chiral and racemic hydrogen-bonded cocrystals that are similar in molecular and supramolecular structure. Terahertz spectroscopy readily distinguished between the isostructural cocrystals of theophylline with chiral and racemic forms of malic acid which are almost identical in molecular structure and supramolecular architecture. Similarly, the cocrystals of theophylline with chiral and racemic forms of tartaric acid, which are similar at the molecular level but dissimilar in crystal packing, were distinguished unequivocally. The investigation of the same cocrystals using X-ray powder diffraction and Raman spectroscopy suggested that THz-TDS is comparable in sensitivity to diffraction methods and more sensitive than Raman spectroscopy to changes in cocrystal architecture. The differences in spectra acquired by THz-TDS could be further enhanced by cooling the samples to 109 K.
|
Minaeva, O., Divochiy, A., Korneev, A., Sergienko, A. V., & Goltsman, G. N. (2009). High speed infrared photon counting with photon number resolving superconducting single-photon detectors (SSPDs). In CLEO/Europe – EQEC.
Abstract: A review of development and characterization of the nanostructures consisting of several meander sections, all connected in parallel was presented. Such geometry leads to a significant decrease of the kinetic inductance, without a decrease of the SSPD active area. A new type of SSPDs possess the QE of large-active- area devices, but, simultaneously, allows achieving short response times and the GHz-counting rate. This new generation of superconducting detectors has another significant advantage for quantum key distribution, they have a photon number resolving capability and can distinguish more photons.
|
Esteban, E., & Serna, H. (2009). Quantum key distribution protocol with private-public key. arXiv, , 3.
Abstract: A quantum cryptographic protocol based in public key cryptography combinations and private key cryptography is presented. Unlike the BB84 protocol 1 and its many variants 2,3 two quantum channels are used. The present research does not make reconciliation mechanisms of information to derive the key. A three related system of key distribution are described.
|
Sekine, N., & Hosako, I. (2009). Intensity modulation of terahertz quantum cascade lasers under external light injection. Appl. Phys. Lett., 95, 201106(1–3).
Abstract: We investigated the light-current characteristics of terahertz (THz) quantum cascade lasers under external light injection, which excites interband transitions in the active materials. It was found that the amount of reduction in the THz power was constant for all injection currents above threshold, and the dependence of the reduction amount on the wavelength of the external light was observed to show a resonancelike feature. The dominant intensity modulation mechanism was found to be the loss change caused by interband transitions in the active region. Further, the effective coupling efficiency plays an important role in the intensity modulation.
|
Cao, Q., Yoon, S. F., Tong, C. Z., Ngo, C. Y., Liu, C. Y., Wang, R., et al. (2009). Two-state competition in 1.3 μm multilayer InAs/InGaAs quantum dot lasers. Appl. Phys. Lett., 95(19), 3.
Abstract: The competition of ground state (GS) and excited state (ES) is investigated from the as-grown and thermally annealed 1.3 μm ten-layer p-doped InAs/GaAs quantum dot (QD) lasers. The modal gain competition between GS and ES are measured and analyzed around the ES threshold characteristics. Our results show that two-state competition is more significant in devices with short cavity length operating at high temperature. By comparing the as-grown and annealed devices, we demonstrate enhanced GS and suppressed ES lasing from the QD laser annealed at 600 °C for 15 s.
|
Yates, S. J. C., Baryshev, A. M., Baselmans, J. J. A., Klein, B., & Güsten, R. (2009). Fast Fourier transform spectrometer readout for large arrays of microwave kinetic inductance detectors. Appl. Phys. Lett., 95(4), 3.
Abstract: Microwave kinetic inductance detectors have great potential for large, very sensitive detector arrays for use in, for example, submillimeter imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing ~1000 s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of fast Fourier transform spectrometer readout, showing no deterioration of the noise performance compared to the low noise analog mixing while allowing high multiplexing ratios.
|