|
Records |
Links |
|
Author |
Slysz, W.; Wegrzecki, M.; Bar, J.; Grabiec, P.; Gorska, M.; Rieger, E.; Dorenbos, P.; Zwiller, V.; Milostnaya, I.; Minaeva, O.; Antipov, A.; Okunev, O.; Korneev, A.; Smirnov, K.; Voronov, B.; Kaurova, N.; Gol’tsman, G.N.; Kitaygorsky, J.; Pan, D.; Pearlman, A.; Cross, A.; Komissarov, I.; Sobolewski, R. |
|
|
Title |
Fiber-coupled NbN superconducting single-photon detectors for quantum correlation measurements |
Type |
Conference Article |
|
Year |
2007 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
|
|
Volume |
6583 |
Issue |
|
Pages |
65830J (1 to 11) |
|
|
Keywords |
NbN SSPD, SNSPD, superconducting single-photon detectors, single-photon detectors, fiber-coupled optical detectors, quantum correlations, superconducting devices |
|
|
Abstract |
We have fabricated fiber-coupled superconducting single-photon detectors (SSPDs), designed for quantum-correlationtype experiments. The SSPDs are nanostructured ( 100-nm wide and 4-nm thick) NbN superconducting meandering stripes, operated in the 2 to 4.2 K temperature range, and known for ultrafast and efficient detection of visible to nearinfrared photons with almost negligible dark counts. Our latest devices are pigtailed structures with coupling between the SSPD structure and a single-mode optical fiber achieved using a micromechanical photoresist ring placed directly over the meander. The above arrangement withstands repetitive thermal cycling between liquid helium and room temperature, and we can reach the coupling efficiency of up to 33%. The system quantum efficiency, measured as the ratio of the photons counted by SSPD to the total number of photons coupled into the fiber, in our early devices was found to be around 0.3 % and 1% for 1.55 &mgr;m and 0.9 &mgr;m photon wavelengths, respectively. The photon counting rate exceeded 250 MHz. The receiver with two SSPDs, each individually biased, was placed inside a transport, 60-liter liquid helium Dewar, assuring uninterrupted operation for over 2 months. Since the receiver’s optical and electrical connections are at room temperature, the set-up is suitable for any applications, where single-photon counting capability and fast count rates are desired. In our case, it was implemented for photon correlation experiments. The receiver response time, measured as a second-order photon cross-correlation function, was found to be below 400 ps, with timing jitter of less than 40 ps. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Spie |
Place of Publication |
|
Editor |
Dusek, M.; Hillery, M.S.; Schleich, W.P.; Prochazka, I.; Migdall, A.L.; Pauchard, A. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Photon Counting Applications, Quantum Optics, and Quantum Cryptography |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1431 |
|
Permanent link to this record |
|
|
|
|
Author |
Minaeva, O.; Fraine, A.; Korneev, A.; Divochiy, A.; Goltsman, G.; Sergienko, A. |
|
|
Title |
High resolution optical time-domain reflectometry using superconducting single-photon detectors |
Type |
Conference Article |
|
Year |
2012 |
Publication |
Frontiers in Opt. 2012/Laser Sci. XXVIII |
Abbreviated Journal |
Frontiers in Opt. 2012/Laser Sci. XXVIII |
|
|
Volume |
|
Issue |
|
Pages |
Fw3a.39 |
|
|
Keywords |
SSPD, SNSPD, Photodetectors; Fiber characterization; Light beams; Optical time domain reflectometry; Photon counting; Single mode fibers; Single photon detectors; Superconductors |
|
|
Abstract |
We discuss the advantages and limitations of single-photon optical time-domain reflectometry with superconducting single-photon detectors. The higher two-point resolution can be achieved due to superior timing performance of SSPDs in comparison with InGaAs APDs. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Optical Society of America |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1237 |
|
Permanent link to this record |
|
|
|
|
Author |
Doi, Y.; Wang, Z.; Ueda, T.; Nickels, P.; Komiyama, S.; Patrashin, M.; Hosako, I.; Matsuura, S.; Shirahata, M.; Sawayama, Y.; Kawada, M. |
|
|
Title |
CSIP – a novel photon-counting detector applicable for the SPICA far-infrared instrument |
Type |
Journal Article |
|
Year |
2009 |
Publication |
SPICA |
Abbreviated Journal |
SPICA |
|
|
Volume |
|
Issue |
SPICA Workshop 2009 |
Pages |
|
|
|
Keywords |
detectors; Infrared |
|
|
Abstract |
We describe a novel GaAs/AlGaAs double-quantumwell device for the infrared photon detection, called ChargeSensitive Infrared Phototransistor (CSIP). The principle of CSIP detector is the photo-excitation of an intersubband transition in a QW as an charge integrating gate and the signal ampli<ef><ac><81>cation by another QW as a channel with very high gain, which provides us with extremely high responsivity (104 – 106 A/W). It has been demonstrated that the CSIP designed for the mid-infrared wavelength (14.7 μm) has an excellent sensitivity; the noise equivalent power (NEP) of 7 × 10-19 W/ with the quantum effciency of ~ 2%. Advantages of the CSIP against the other highly sensitive detectors are, huge dynamic range of > 106, low output impedance of 103 – 104 Ohms, and relatively high operation temperature (> 2 K). We discuss possible applications of the CSIP to FIR photon detection covering 35 – 60 μm waveband, which is a gap uncovered with presently available photoconductors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
RPLAB @ gujma @ |
Serial |
672 |
|
Permanent link to this record |
|
|
|
|
Author |
Verevkin, A.; Slysz, W.; Pearlman, A.; Zhang, J.; Sobolewski, R.; Okunev, O.; Korneev, A.; Kouminov, P.; Smirnov, K.; Chulkova, G.; Gol’tsman, G. N.; Currie, M. |
|
|
Title |
Real-time GHz-rate counting of infrared photons using nanostructured NbN superconducting detectors |
Type |
Conference Article |
|
Year |
2003 |
Publication |
CLEO/QELS |
Abbreviated Journal |
CLEO/QELS |
|
|
Volume |
|
Issue |
|
Pages |
CThM8 |
|
|
Keywords |
NbN SSPD; SNSPD; Infrared; Quantum detectors; Detectors; Photon counting; Quantum communications; Quantum cryptography; Single photon detectors; Superconductors |
|
|
Abstract |
We demonstrate that our ultrathin, nanometer-width NbN superconducting single-photon detectors are capable of above 1-GHz-frequency, real-time counting of near-infrared photons. The measured system jitter of the detector is below 15 ps. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Optical Society of America |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1517 |
|
Permanent link to this record |
|
|
|
|
Author |
Marsili, F.; Bitauld, D.; Divochiy, A.; Gaggero, A.; Leoni, R.; Mattioli, F.; Korneev, A.; Seleznev, V.; Kaurova, N.; Minaeva, O.; Gol’tsman, G.; Lagoudakis, K.G.; Benkahoul, M.; Lévy, F.; Fiore, A. |
|
|
Title |
Superconducting nanowire photon number resolving detector at telecom wavelength |
Type |
Conference Article |
|
Year |
2008 |
Publication |
CLEO/QELS |
Abbreviated Journal |
CLEO/QELS |
|
|
Volume |
|
Issue |
|
Pages |
Qmj1 (1 to 2) |
|
|
Keywords |
PNR SSPD; SNSPD; Detectors; Infrared; Low light level; Diode lasers; Photons; Scanning electron microscopy; Superconductors; Ti:sapphire lasers |
|
|
Abstract |
We demonstrate a photon-number-resolving (PNR) detector, based on parallel superconducting nanowires, capable of resolving up to 5 photons in the telecommunication wavelength range, with sensitivity and speed far exceeding existing approaches. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Optical Society of America |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-1-55752-859-9 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
Marsili:08 |
Serial |
1243 |
|
Permanent link to this record |
|
|
|
|
Author |
Ryzhii, V.; Otsuji, T.; Ryzhii, M.; Leiman, V. G.; Fedorov, G.; Goltzman, G. N.; Gayduchenko, I. A.; Titova, N.; Coquillat, D.; But, D.; Knap, W.; Mitin, V.; Shur, M. S. |
|
|
Title |
Two-dimensional plasmons in lateral carbon nanotube network structures and their effect on the terahertz radiation detection |
Type |
Journal Article |
|
Year |
2016 |
Publication |
J. Appl. Phys. |
Abbreviated Journal |
J. Appl. Phys. |
|
|
Volume |
120 |
Issue |
4 |
Pages |
044501 (1 to 13) |
|
|
Keywords |
carbon nanotubes, CNT detectors, plasmons |
|
|
Abstract |
We consider the carrier transport and plasmonic phenomena in the lateral carbon nanotube (CNT) networks forming the device channel with asymmetric electrodes. One electrode is the Ohmic contact to the CNT network and the other contact is the Schottky contact. These structures can serve as detectors of the terahertz (THz) radiation. We develop the device model for collective response of the lateral CNT networks which comprise a mixture of randomly oriented semiconductor CNTs (s-CNTs) and quasi-metal CNTs (m-CNTs). The proposed model includes the concept of the collective two-dimensional (2D) plasmons in relatively dense networks of randomly oriented CNTs (CNT “felt”) and predicts the detector responsivity spectral characteristics exhibiting sharp resonant peaks at the signal frequencies corresponding to the 2D plasmonic resonances. The detection mechanism is the rectification of the ac current due the nonlinearity of the Schottky contact current-voltage characteristics under the conditions of a strong enhancement of the potential drop at this contact associated with the plasmon excitation. The detector responsivity depends on the fractions of the s- and m-CNTs. The burning of the near-contact regions of the m-CNTs or destruction of these CNTs leads to a marked increase in the responsivity in agreement with our experimental data. The resonant THz detectors with sufficiently dense lateral CNT networks can compete and surpass other THz detectors using plasmonic effects at room temperatures. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0021-8979 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1777 |
|
Permanent link to this record |
|
|
|
|
Author |
Fedorov, G. E.; Stepanova, T. S.; Gazaliev, A. S.; Gaiduchenko, I. A.; Kaurova, N. S.; Voronov, B. M.; Goltzman, G. N. |
|
|
Title |
Asymmetric devices based on carbon nanotubes for terahertz-range radiation detection |
Type |
Journal Article |
|
Year |
2016 |
Publication |
Semicond. |
Abbreviated Journal |
Semicond. |
|
|
Volume |
50 |
Issue |
12 |
Pages |
1600-1603 |
|
|
Keywords |
carbon nanotubes, CNT detectors |
|
|
Abstract |
Various asymmetric detecting devices based on carbon nanotubes (CNTs) are studied. The asymmetry is understood as inhomogeneous properties along the conducting channel. In the first type of devices, an inhomogeneous morphology of the CNT grid is used. In the second type of devices, metals with highly varying work functions are used as the contact material. The relation between the sensitivity and detector configuration is analyzed. Based on the data obtained, approaches to the development of an efficient detector of terahertz radiation, based on carbon nanotubes are proposed. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1063-7826 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1776 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol’tsman, G. N.; Semenov, A. D.; Sergeev, A. V. |
|
|
Title |
Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation |
Type |
Journal Article |
|
Year |
1991 |
Publication |
IEEE Trans. Magn. |
Abbreviated Journal |
IEEE Trans. Magn. |
|
|
Volume |
27 |
Issue |
2 |
Pages |
1321-1324 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
Ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter waves to near infrared. With an increase in radiation frequency, the Josephson detection at the grain-boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. The electron-phonon relaxation time tau /sub eph/ is determined from direct measurements, quasi-stationary electron heating measurements, and the frequency dependence of the current at which maximum voltage shift is observed. The temperature dependence of tau /sub eph/ at T<or=40 K was found to be tau /sub eph/ approximately T/sup -1/. The results show that detectors with a response time of a few picoseconds at nitrogen temperature are attainable. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1941-0069 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1679 |
|
Permanent link to this record |
|
|
|
|
Author |
Kahl, O.; Ferrari, S.; Kovalyuk, V.; Vetter, A.; Lewes-Malandrakis, G.; Nebel, C.; Korneev, A.; Goltsman, G.; Pernice, W. |
|
|
Title |
Spectrally multiplexed single-photon detection with hybrid superconducting nanophotonic circuits: supplementary material |
Type |
Miscellaneous |
|
Year |
2017 |
Publication |
Optica |
Abbreviated Journal |
|
|
|
Volume |
|
Issue |
|
Pages |
1-9 |
|
|
Keywords |
Quantum detectors; Spectrometers and spectroscopic instrumentation; Nanophotonics and photonic crystals; Fluorescence correlation spectroscopy; Fluorescence resonance energy transfer; Fluorescence spectroscopy; Imaging techniques; Optical components; Quantum key distribution |
|
|
Abstract |
This document provides supplementary information to “Spectrally multiplexed single-photon detection with hybrid superconducting nanophotonic circuits", DOI:10.1364/optica.4.000557. Here we detail the on-chip spectrometer design, its characterization and the experimental setup we used. In addition, we present a detailed report concerning the characterization of the superconducting nanowire single photon detectors. In the final sections, we describe sample preparation and characterization of the nanodiamonds containing silicon vacancy color centers. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Osa |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
Kahl:17 |
Serial |
1218 |
|
Permanent link to this record |
|
|
|
|
Author |
Semenov, A. D.; Goghidze, I. G.; Gol’tsman, G. N.; Sergeev, A. V.; Aksaev, E. E.; Gershenzon, E. M. |
|
|
Title |
Non-equilibrium quasiparticle response to radiation and bolometric effect in YBaCuO films |
Type |
Journal Article |
|
Year |
1993 |
Publication |
IEEE Trans. Appl. Supercond. |
Abbreviated Journal |
IEEE Trans. Appl. Supercond. |
|
|
Volume |
3 |
Issue |
1 |
Pages |
2132-2135 |
|
|
Keywords |
YBCO HTS HEB detectors |
|
|
Abstract |
The voltage photoresponse of structured current biased YBCO films on different substrates to 20-ps laser pulses of 0.63- mu m and 1.54- mu m wavelengths and to continuously modulated radiation of 2-mm wavelength is measured to temperatures around Tc. Fast picosecond decay of the response to pulsed radiation is followed by slow exponential relaxation with a nanosecond characteristic time depending on the substrate material and film dimensions. The slow component does not depend on wavelength and is attributed to the bolometric effect, while the magnitude of the fast component associated with nonequilibrium response rises with wavelength. More than an order-of-magnitude increase of the nonequilibrium response is seen from near-infrared to millimeter-wave range. This dependence plausibly reflects the low efficiency of multiplication of photoexcited electrons in YBaCuO compared to conventional superconductors. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1558-2515 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1659 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Gogidze, I. G.; Semenov, A. D.; Sergeev, A. V. |
|
|
Title |
Processes of electron-phonon interaction in thin YBaCuO films |
Type |
Journal Article |
|
Year |
1991 |
Publication |
Phys. C: Supercond. |
Abbreviated Journal |
Phys. C: Supercond. |
|
|
Volume |
185-189 |
Issue |
|
Pages |
1371-1372 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
The ultrafast voltage response of YBaCuO films to laser radiation is studied and compared with previously investigated quasiparicles response to radiation of submillimeter wavelength range. Voltage shift under the visible light radiation has two components. Picosecond response realized as suppression superconductivity by nonequilibrium excess quasiparticles, response time is determined by quasiparticles recombination rate. Nanosecond response is probably due to bolometric effect. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0921-4534 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1676 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Semenov, A. D.; Sergeev, A. V. |
|
|
Title |
Mechanism of picosecond response of granular YBaCuO films to electromagnetic radiation |
Type |
Journal Article |
|
Year |
1990 |
Publication |
Solid State Communications |
Abbreviated Journal |
Solid State Communications |
|
|
Volume |
76 |
Issue |
4 |
Pages |
493-497 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
The ultrafast mechanisms of radiation detection in granular YBaCuO films are studied in the wide wavelength range from millimeter to near infrared. With the rise of radiation frequency the Josephson detection at the grain boundary weak links is replaced by electron heating into the grains. This change occurs in the submillimeter wavelength range. Electron-phonon relaxation time τeph is determined by direct measurements and analyses quasistationary electron heating. Temperature dependence of τeph at T ≤ 40 K was found to be τeph ∼ T−1. The results show that detectors with the response time of few picoseconds at nitrogen temperature are attainable. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0038-1098 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1685 |
|
Permanent link to this record |
|
|
|
|
Author |
Semenov, A. D.; Goghidze, I. G.; Gol’tsman, G. N.; Sergeev, A. V.; Gershenzon, E. M. |
|
|
Title |
Evidence for the spectral dependence of nonequilibrium picosecond photoresponse of YBaCuO thin films |
Type |
Journal Article |
|
Year |
1993 |
Publication |
Appl. Phys. Lett. |
Abbreviated Journal |
Appl. Phys. Lett. |
|
|
Volume |
63 |
Issue |
5 |
Pages |
681-683 |
|
|
Keywords |
YBCO HTS detectors, nonequilibrium |
|
|
Abstract |
The transient voltage photoresponse of current biased YBaCuO thin films to 20 ps laser pulses of 0.63 and 1.54 μm wavelengths is measured for temperatures around the superconducting transition region. The fast picosecond decay of the response is followed by a slow nanosecond relaxation which is associated with the bolometric effect. The magnitude of the fast component of the response varies in proportion to the square root of wavelength that plausibly reflects multiplication processes of photoexcited electrons via electron–electron scattering and interaction with high energy phonons. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-6951 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1655 |
|
Permanent link to this record |
|
|
|
|
Author |
Gol’tsman, G. N.; Semenov, A. D.; Sergeev, A. V.; Aksaev, E. E.; Gogidze, I. G.; Gershenzon, E. M. |
|
|
Title |
Electron-phonon interaction in thin YBaCuO films and fast detectors |
Type |
Conference Article |
|
Year |
1993 |
Publication |
Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences |
Abbreviated Journal |
Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences |
|
|
Volume |
112 |
Issue |
|
Pages |
184-185 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
The thin. YBaCuO film response to laser and submillimeter radiation demonstrates the picosecond nonequilibrium peak on the nanosecond bolometric background. Experimental data give an evidence for the spectral dependence of picosecond photoresponse probably due to a poor efficiency of electron multiplication processes. Presented results prove an availability of fast YBaCuO thin film detector. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
Meissner, M.; Pohl, R. O. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Seventh International Conference, Cornell University, Ithaca, New York, August 3-7, 1992 |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1662 |
|
Permanent link to this record |
|
|
|
|
Author |
Akhmadishina, K. F.; Bobrinetskiy, I. I.; Komarov, I. A.; Malovichko, A. M.; Nevolin, V. K.; Fedorov, G. E.; Golovin, A. V.; Zalevskiy, A. O.; Aidarkhanov, R. D. |
|
|
Title |
Fast-response biological sensors based on single-layer carbon nanotubes modified with specific aptamers |
Type |
Journal Article |
|
Year |
2015 |
Publication |
Semicond. |
Abbreviated Journal |
Semicond. |
|
|
Volume |
49 |
Issue |
13 |
Pages |
1749-1753 |
|
|
Keywords |
carbon nanotubes, CNT detectors |
|
|
Abstract |
The possibility of the fabrication of a fast-response biological sensor based on a composite of single-layer carbon nanotubes and aptamers for the specific detection of proteins is shown. The effect of modification of the surface of the carbon nanotubes on the selectivity and sensitivity of the sensors is investigated. It is shown that carboxylated nanotubes have a better selectivity for detecting thrombin. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1063-7826 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1783 |
|
Permanent link to this record |