Author Ejrnaes, M.; Cristiano, R.; Quaranta, O.; Pagano, S.; Gaggero, A.; Mattioli, F.; Leoni, R.; Voronov, B.; Gol’tsman, G. url  doi
openurl 
  Title A cascade switching superconducting single photon detector Type Journal Article
  Year 2007 Publication Appl. Phys. Lett. Abbreviated Journal Appl. Phys. Lett.  
  Volume 91 Issue 26 Pages 262509 (1 to 3)  
  Keywords SSPD, SNSPD, parallel-wire  
  Abstract (down) We have realized superconducting single photon detectors with reduced inductance and increased signal pulse amplitude. The detectors are based on a parallel connection of ultrathin NbN nanowires with a common bias inductance. When properly biased, an absorbed photon induces a cascade switch of all the parallel wires generating a signal pulse amplitude of 2mV. The parallel wire configuration lowers the detector inductance and reduces the response time well below 1ns.

This work was performed in the framework of the EU project “SINPHONIA” NMP4-CT-2005-016433.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-6951 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1418  
Permanent link to this record
 

 
Author Genack, Azriel Z.; Kopp, Victor I.; Churikov, Victor M.; Singer, Jonathan; Chao, Norman; Neugroschl, Daniel A. openurl 
  Title Chiral fiber Bragg gratings Type Conference Article
  Year 2004 Publication Proceedings of the SPIE Abbreviated Journal Proc. SPIE  
  Volume 5508 Issue Pages 57-64  
  Keywords optical fiber gratings, chiral fiber gratings, chiral gratings, from chiralphotonics  
  Abstract (down) We have produced chiral fiber Bragg gratings with double-helix symmetry and measured the polarization and wavelength selective transmission properties of these structures. These gratings interact only with circularly polarized light with the same handedness as the grating twist and freely transmit light of the orthogonal polarization. The optical characteristics of chiral fibers are compared to those of planar cholesteric structures. The resonant standing wave at the band edge or at a defect state within the band gap, as well as the evanescent wave within the band gap is comprised of two counterpropagating components of equal amplitude. The electric field vector of such a circularly polarized standing wave does not rotate in time; rather it is linearly polarized in any given plane. The standing wave may be described in terms of the sense of circular polarization of the two counterpropagating components. The wavelength dependence of the angle q between the linearly polarized electromagnetic field and the extraordinary axis, which is constant throughout a long structure, is obtained in a simple calculation. The results are in good agreement with scattering matrix calculations. Resonant chiral gratings are demonstrated for microwave radiation whereas chiral gratings with pitch exceeding the wavelength are demonstrated at optical wavelengths in single-mode glass fibers. The different functionalities of these fibers are discussed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 854  
Permanent link to this record
 

 
Author Gerecht, E.; Musante, C. F.; Schuch, R.; Lutz, C. R.; Jr.; Yngvesson, K. S.; Mueller, E. R.; Waldivian, J.; Gol'tsman, G. N.; Voronov, B. M.; Gershenzon, E. M. url  openurl
  Title Hot electron detection and mixing experiments in NbN at 119 micrometer wavelength Type Conference Article
  Year 1995 Publication Proc. 6th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 6th Int. Symp. Space Terahertz Technol.  
  Volume Issue Pages 284-293  
  Keywords NbN HEB mixers, detectors  
  Abstract (down) We have performed preliminary experiments with the goal of demonstrating a Hot Electron Bolometric (HEB) mixer for a 119 micrometer wavelength (2.5 THz). We have chosen a NbN device of size 700 x 350 micrometers. This device can easily be coupled to a laser LO source, which is advantageous for performing a prototype experiment. The relatively large size of the device means that the LO power required is in the mW range; this power can be easily obtained from a THz laser source. We have measured the amount of laser power actually absorbed in the device, and from this have estimated the best optical coupling loss to be about 10 di . We are developing methods for improving the optical coupling further. Preliminary measurements of the response of the device to a chopped black-body have not yet resulted in a measured receiver noise temperature. We expect to be able to complete this measurement in the near future.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1629  
Permanent link to this record
 

 
Author Tong, C.-Y.E.; Meledin, D.V.; Marrone, D.P.; Paine, S.N.; Gibson, H.; Blundell, R. url  doi
openurl 
  Title Near field vector beam measurements at 1 THz Type Journal Article
  Year 2003 Publication IEEE Microw. Compon. Lett. Abbreviated Journal  
  Volume 13 Issue 6 Pages 235-237  
  Keywords HEB, mixer, waveguide, LO power, local oscillator power, saturation effect, dynamic range  
  Abstract (down) We have performed near-field vector beam measurements at 1.03 THz to characterize and align the receiver optics of a superconducting receiver. The signal source is a harmonic generator mounted on an X-Y translation stage. We model the measured two-dimensional complex beam pattern by a fundamental Gaussian mode, from which we derive the position of the beam center, the beam radius and the direction of propagation. By performing scans in the planes separated by 400 mm, we have confirmed that our beam pattern measurements are highly reliable.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1531-1309 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ lobanovyury @ Serial 574  
Permanent link to this record
 

 
Author Lobanov, Y.; Tong, C.; Blundell, R.; Gol'tsman, G. url  openurl
  Title A study of direct detection effect on the linearity of hot electron bolometer mixers Type Conference Article
  Year 2009 Publication Proc. 20th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 20th ISSTT  
  Volume Issue Pages 282-287  
  Keywords HEB mixer, direct detection effect  
  Abstract (down) We have performed a study of how direct detection affects the linearity and hence the calibration of an HEB mixer. Two types of waveguide HEB devices have been used: a 0.8 THz HEB mixer and a 1.0 THz HEB mixer which is ~5 times smaller than the former. Two independent experimental approaches were used. In the ΔG/G method, the conversion gain of the HEB mixer is first measured as a function of the bias current for a number of bias voltages. At each bias setting, we carefully measure the change in the operating current when the input loads are switched. From the measured data, we can derive the expected difference in gain between the hot and cold loads. In the second method (injection method [1]), the linearity of the HEB mixer is independently measured by injecting a modulated signal for different input load temperatures. The results of both approaches confirm that there is gain compression in the operation of HEB mixers. Based on the results of our measurements, we discuss the impact of direct detection effects on the operation of HEB mixers.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 724  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: