|
Records |
Links |
|
Author |
Prokhodtsov, A.; Golikov, A.; An, P.; Kovalyuk, V.; Goltsman, G.; Arakelyan, S.; Evlyukhin, A.; Kalachev, A.; Naumov, A. |
|
|
Title |
Effect of silicon oxide coating on a silicon nitride focusing grating coupler efficiency |
Type |
Conference Article |
|
Year |
2019 |
Publication |
EPJ Web Conf. |
Abbreviated Journal |
EPJ Web Conf. |
|
|
Volume |
220 |
Issue |
|
Pages |
02009 |
|
|
Keywords |
grating coupler, SiO2 |
|
|
Abstract |
The dependence of the efficiency of the focusing grating couplers on the period and filling factor before and after deposition of the upper silicon oxide layer was experimentally studied. The obtained data are of practical importance for tunable integrated-optical devices based on silicon nitride platform. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2100-014X |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1188 |
|
Permanent link to this record |
|
|
|
|
Author |
Anfertev, V.; Vaks, V.; Revin, L.; Pentin, I.; Tretyakov, I.; Goltsman, G.; Vinogradov, E. A.; Naumov, A. V.; Gladush, M. G.; Karimullin, K. R. |
|
|
Title |
High resolution THz gas spectrometer based on semiconductor and superconductor devices |
Type |
Conference Article |
|
Year |
2017 |
Publication |
EPJ Web Conf. |
Abbreviated Journal |
EPJ Web Conf. |
|
|
Volume |
132 |
Issue |
|
Pages |
02001 (1 to 2) |
|
|
Keywords |
NbN HEB mixers, detectors, THz spectroscopy |
|
|
Abstract |
The high resolution THz gas spectrometer consists of a synthesizer based on Gunn generator with a semiconductor superlattice frequency multiplier as a radiation source, and an NbN hot electron bolometer in a direct detection mode as a THz radiation receiver was presented. The possibility of application of a quantum cascade laser as a local oscillator for a heterodyne receiver which is based on an NbN hot electron bolometer mixer is shown. The ways for further developing of the THz spectroscopy were outlined. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2100-014X |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1328 |
|
Permanent link to this record |
|
|
|
|
Author |
Elezov, M.; Scherbatenko, M.; Sych, D.; Goltsman, G.; Arakelyan, S.; Evlyukhin, A.; Kalachev, A.; Naumov, A. |
|
|
Title |
Towards the fiber-optic Kennedy quantum receiver |
Type |
Conference Article |
|
Year |
2019 |
Publication |
EPJ Web Conf. |
Abbreviated Journal |
EPJ Web Conf. |
|
|
Volume |
220 |
Issue |
|
Pages |
03011 (1 to 2) |
|
|
Keywords |
SSPD, SNSPD, Kennedy quantum receiver |
|
|
Abstract |
We consider practical aspects of using standard fiber-optic elements and superconducting nanowire single-photon detectors for the development of a practical quantum receiver based on the Kennedy scheme. Our receiver allows to discriminate two phase-modulated coherent states of light at a wavelength of 1.5 microns in continuous mode with bit rate 200 Kbit/s and error rate about two times below the standard quantum limit. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2100-014X |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1288 |
|
Permanent link to this record |
|
|
|
|
Author |
Lobanov, Y. V.; Shcherbatenko, M. L.; Semenov, A. V.; Kovalyuk, V. V.; Korneev, A. A.; Goltsman, G. N.; Vinogradov, E. A.; Naumov, A. V.; Gladush, M. G.; Karimullin, K. R. |
|
|
Title |
Heterodyne spectroscopy with superconducting single-photon detector |
Type |
Conference Article |
|
Year |
2017 |
Publication |
EPJ Web Conf. |
Abbreviated Journal |
EPJ Web Conf. |
|
|
Volume |
132 |
Issue |
|
Pages |
01005 |
|
|
Keywords |
SSPD mixer, SNSPD |
|
|
Abstract |
We demonstrate successful operation of a Superconducting Single Photon Detector (SSPD) as the core element in a heterodyne receiver. Irradiating the SSPD by both a local oscillator power and signal power simultaneously, we observed beat signal at the intermediate frequency of a few MHz. Gain bandwidth was found to coincide with the detector single pulse width, where the latter depends on the detector kinetic inductance, determined by the superconducting nanowire length. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2100-014X |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1205 |
|
Permanent link to this record |
|
|
|
|
Author |
Korneeva, Y.; Vodolazov, D.; Florya, I.; Manova, N.; Smirnov, E.; Korneev, A.; Mikhailov, M.; Goltsman, G.; Klapwijk, T. M.; Naumov, A. V.; Gladush, M. G.; Karimullin, K. R. |
|
|
Title |
Single photon detection in micron scale NbN and α-MoSi superconducting strips |
Type |
Conference Article |
|
Year |
2018 |
Publication |
EPJ Web Conf. |
Abbreviated Journal |
EPJ Web Conf. |
|
|
Volume |
190 |
Issue |
|
Pages |
04010 (1 to 2) |
|
|
Keywords |
SSPD |
|
|
Abstract |
We experimentally demonstrate the single photon detection in straight micrometer-wide NbN and α-MoSi bridges. Width of the bridges is 2 µm, while the wavelength of the photon changes from 408 to 1550 nm and critical current exceeds 50% of the depairing current. Obtained results offer the alternative route for design of detectors without resonator and meander structure and indirectly confirm vortex assisted mechanism of single photon detection. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
2100-014X |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1319 |
|
Permanent link to this record |