Burke, P. J., Schoelkopf, R. J., Prober, D. E., Skalare, A., Karasik, B. S., Gaidis, M. C., et al. (1998). Spectrum of thermal fluctuation noise in diffusion and phonon cooled hot-electron mixers. Appl. Phys. Lett., 72(12), 1516–1518.
Abstract: A systematic study of the intermediate frequency noise bandwidth of Nb thin-film superconducting hot-electron bolometers is presented. We have measured the spectrum of the output noise as well as the conversion efficiency over a very broad intermediate frequency range (from 0.1 to 7.5 GHz) for devices varying in length from 0.08 μm to 3 μm. Local oscillator and rf signals from 8 to 40 GHz were used. For a device of a given length, the spectrum of the output noise and the conversion efficiency behave similarly for intermediate frequencies less than the gain bandwidth, in accordance with a simple thermal model for both the mixing and thermal fluctuation noise. For higher intermediate frequencies the conversion efficiency decreases; in contrast, the noise decreases but has a second contribution which dominates at higher frequency. The noise bandwidth is larger than the gain bandwidth, and the mixer noise is low, between 120 and 530 K (double side band).
|
|
|
Terai, H., Miki, S., Yamashita, T., Makise, K., & Wang, Z. (2010). Demonstration of single-flux-quantum readout operation for superconducting single-photon detectors. Appl. Phys. Lett., 97(11), 3.
Abstract: A readout circuit using superconducting single-flux-quantum (SFQ) circuits has been developed to realize an independently addressable array of superconducting single-photon detectors (SSPDs). We tested the SFQ readout circuits by connecting with SSPDs. The error rates of readout circuits were below 10–5 for input signal amplitude of greater than 18.2 μA. Detection efficiencies (DEs) for single-photon incidents were measured both with and without the connection of a readout circuit. The observed DEs traced almost the same curves regardless of the connection of the readout circuit, except that the SSPD is likely to latch by connecting the readout circuit.
|
|
|
Zinoni, C., Alloing, B., Li, L. H., Marsili, F., Fiore, A., Lunghi, L., et al. (2010). Erratum: “Single photon experiments at telecom wavelengths using nanowire superconducting detectors” [Appl. Phys. Lett. 91, 031106 (2007)]. Appl. Phys. Lett., 96(8), 089901.
Abstract: A calculation error was made in the original publication of this letter. The error was in the calculation of the noise equivalent power (NEP) values for the avalanche photodiode detector (APD) and the superconducting single photon detector (SSPD), the incorrect values were plotted on the right axis in Fig. 1(b). The correct NEP values were calculated with the same equation reported in the original letter and the revised Fig. 1(b) is shown below. The other conclusions of the paper remain unaltered.
|
|
|
Tarkhov, M., Claudon, J., Poizat, J. P., Korneev, A., Divochiy, A., Minaeva, O., et al. (2008). Ultrafast reset time of superconducting single photon detectors. Appl. Phys. Lett., 92(24), 241112 (1 to 3).
|
|
|
Hadfield, R. H., Habif, J. L., Schlafer, J., Schwall, R. E., & Nam, S. W. (2006). Quantum key distribution at 1550 nm with twin superconducting single-photon detectors. Appl. Phys. Lett., 89(24), 241129.
|
|