Korneeva, Y., Sidorova, M., Semenov, A., Krasnosvobodtsev, S., Mitsen, K., Korneev, A., et al. (2016). Comparison of hot-spot formation in NbC and NbN single-photon detectors. IEEE Trans. Appl. Supercond., 26(3), 1–4.
Abstract: We report an experimental investigation of the hot-spot evolution in superconducting single-photon detectors made of disordered superconducting materials with different diffusivity and energy downconversion time values, i.e., 33-nm-thick NbN and 23-nm-thick NbC films. We have demonstrated that, in NbC film, only 405-nm photons produce sufficiently large hot spot to trigger a single-photon response. The dependence of detection efficiency on bias current for 405-nm photons in NbC is similar to that for 3400-nm photons in NbN. In NbC, large diffusivity and downconversion time result in 1-D critical current suppression profile compared with the usual 2-D profile in NbN.
|
|
|
Il'in, K. S., Verevkin, A. A., Gol'tsman, G. N., & Sobolewski, R. (1999). Infrared hot-electron NbN superconducting photodetectors for imaging applications. Supercond. Sci. Technol., 12(11), 755–758.
Abstract: We report an effective quantum efficiency of 340, responsivity >200 A W-1 (>104 V W-1) and response time of 27±5 ps at temperatures close to the superconducting transition for NbN superconducting hot-electron photodetectors (HEPs) in the near-infrared and optical ranges. Our studies were performed on a few nm thick NbN films deposited on sapphire substrates and patterned into µm-size multibridge detector structures, incorporated into a coplanar transmission line. The time-resolved photoresponse was studied by means of subpicosecond electro-optic sampling with 100 fs wide laser pulses. The quantum efficiency and responsivity studies of our photodetectors were conducted using an amplitude-modulated infrared beam, fibre-optically coupled to the device. The observed picosecond response time and the very high efficiency and sensitivity of the NbN HEPs make them an excellent choice for infrared imaging photodetectors and input optical-to-electrical transducers for superconducting digital circuits.
|
|
|
Tretyakov, I., Ryabchun, S., Finkel, M., Maslennikova, A., Kaurova, N., Lobastova, A., et al. (2011). Low noise and wide bandwidth of NbN hot-electron bolometer mixers. Appl. Phys. Lett., 98, 033507 (1 to 3).
Abstract: We report a record double sideband noise temperature of 600 K (5hν/kB) offered by a NbN hot-electron bolometer receiver at 2.5 THz. Allowing for standing wave effects, this value was found to be constant in the intermediate frequency range 1–7 GHz, which indicates that the mixer has an unprecedentedly large noise bandwidth in excess of 7 GHz. The insight into this is provided by gain bandwidth measurements performed at the superconducting transition. They show that the dependence of the bandwidth on the mixer length follows the model for an HEB mixer with diffusion and phonon cooling of the hot electrons.
|
|
|
Tretyakov, I., Ryabchun, S., Finkel, M., Maslennikov, S., Maslennikova, A., Kaurova, N., et al. (2011). Ultrawide noise bandwidth of NbN hot-electron bolometer mixers with in situ gold contacts. IEEE Trans. Appl. Supercond., 21(3), 620–623.
Abstract: We report a noise bandwidth of 7 GHz in the new generation of NbN hot-electron bolometer (HEB) mixers that are being developed for the space observatory Millimetron. The HEB receiver driven by a 2.5-THz local oscillator offered a noise temperature of 600 K in a 50-MHz final detection bandwidth. As the filter center frequency was swept this value remained nearly constant up to the cutoff frequency of the cryogenic amplifier at 7 GHz. We believe that such a low value of the noise temperature is due to reduced radio frequency (RF) loss at the interface between the superconducting film and the gold contacts. We have also performed gain bandwidth measurements at the superconducting transition on HEB mixers with various lengths and found them to be in excellent agreement with the results of the analytical and numerical models developed for the HEB mixer with both diffusion and phonon cooling of hot electrons.
|
|
|
Santhanam, P., Wind, S., & Prober, D. E. (1987). Localization, superconducting fluctuations, and superconductivity in thin films and narrow wires of aluminum. Phys. Rev. B, 35(7), 3188–3206.
Abstract: We report a comprehensive set of experiments on wide and narrow thin-film strips of aluminum which test the predictions of recent localization theory. The experiments on wide films in the two-dimensional regime confirm the theoretical predictions and also yield insight into inelastic mechanisms and spin-orbit scattering rates. Our extension of the existing theory for one-dimensional systems to include spin-orbit scattering and Maki-Thompson superconducting fluctuations is verified by the experiments. We find clear evidence for one-dimensional localization, with inferred inelastic rates identical to those in two-dimensional films. The prediction of the localization theory for a dimensional crossover from two-dimensional to one-dimensional behavior is also confirmed. We have reanalyzed the results of some previous experiments on thin films and narrow wires in light of these results.
|
|