Rath, P., Vetter, A., Kovalyuk, V., Ferrari, S., Kahl, O., Nebel, C., et al. (2016). Travelling-wave single-photon detectors integrated with diamond photonic circuits: operation at visible and telecom wavelengths with a timing jitter down to 23 ps. In J. - E. Broquin, & G. N. Conti (Eds.), Integrated Optics: Devices, Mat. Technol. XX (Vol. 9750, pp. 135–142). Spie.
Abstract: We report on the design, fabrication and measurement of travelling-wave superconducting nanowire single-photon detectors (SNSPDs) integrated with polycrystalline diamond photonic circuits. We analyze their performance both in the near-infrared wavelength regime around 1600 nm and at 765 nm. Near-IR detection is important for compatibility with the telecommunication infrastructure, while operation in the visible wavelength range is relevant for compatibility with the emission line of silicon vacancy centers in diamond which can be used as efficient single-photon sources. Our detectors feature high critical currents (up to 31 μA) and high performance in terms of efficiency (up to 74% at 765 nm), noise-equivalent power (down to 4.4×10-19 W/Hz1/2 at 765 nm) and timing jitter (down to 23 ps).
|
Sclafani, M., Marksteiner, M., Keir, F. M. L., Divochiy, A., Korneev, A., Semenov, A., et al. (2012). Sensitivity of a superconducting nanowire detector for single ions at low energy. Nanotechnol., 23(6), 065501 (1 to 5).
Abstract: We report on the characterization of a superconducting nanowire detector for ions at low kinetic energies. We measure the absolute single-particle detection efficiency eta and trace its increase with energy up to eta = 100%. We discuss the influence of noble gas adsorbates on the cryogenic surface and analyze their relevance for the detection of slow massive particles. We apply a recent model for the hot-spot formation to the incidence of atomic ions at energies between 0.2 and 1 keV. We suggest how the differences observed for photons and atoms or molecules can be related to the surface condition of the detector and we propose that the restoration of proper surface conditions may open a new avenue for SSPD-based optical spectroscopy on molecules and nanoparticles.
|
Tovpeko, N. A., Trifonov, A. V., Semenov, A. V., Antipov, S. V., Kaurova, N. S., Titova, N. A., et al. (2019). Bandwidth performance of a THz normal metal TiN bolometer-mixer. In Proc. 30th Int. Symp. Space Terahertz Technol. (pp. 102–103).
Abstract: We report on the bandwidth performance of the normal metal TiN bolometer-mixer on top of an Al 2 O 3 substrate, which is capable to operate in a wide range of bath temperatures from 77 K – 300 K. The choice of the combination TiN / Al 2 O 3 is related to an advanced heat transport between the film and the substrate in this pair and the sufficient temperature coefficient of resistance. The data were taken at 132.5 – 145.5 GHz with two BWOs as a signal and an LO source. Measurements were taken on TiN films of different thickness starting from 20 nm down to 5 nm coupled into a spiral Au antenna, which improves matching of incoming radiation with the thin TiN fim. Our experiments demonstrate effective heat coupling from a TiN thin film to an Al 2 O 3 substrate (111) boosting gain bandwidth (GB) of TiN bolometer up to 6 GHz for 5 nm thin film. Current results indicate weak temperature dependence of GB on the bath temperature of the TiN bolometer. Theoretical estimations of GB performance meet with experimental data for 5 nm thin TiN films.
|
Bryerton, E., Percy, R., Bass, R., Schultz, J., Oluleye, O., Lichtenberger, A., et al. (2005). Receiver measurements of pHEB beam lead mixers on 3-μm silicon. In Proc. 30th IRMMW / 13th THz (pp. 271–272).
Abstract: We report on receiver noise measurement results of phonon-cooled HEB beam lead mixers on 3 μm thick silicon. This type of ultra-thin mixer chip with integrated beam leads allows easy assembly into a block and holds great promise for array integration. Receiver measurements from 600-720 GHz are presented with a minimum noise temperature of 500 K at 666 GHz. These results verify the mixer performance of the SOI processing techniques allowing for further design and integration of SOI pHEB mixers in receivers operating above 1 THz.
|
Tretyakov, I., Seliverstov, S., Zolotov, P., Kaurova, N., Voronov, B., Finkel, M., et al. (2014). Noise temperature and noise bandwidth of hot-electron bolometer mixer at 3.8 THz. In Proc. 25th Int. Symp. Space Terahertz Technol. (77).
Abstract: We report on our recent results of double sideband (DSB) noise temperature and bandwidth measurements of quasi-optical hot electron bolometer (HEB) mixers at local oscillator frequency of 3.8 THz. The HEB mixers used in this work were made of a NbN thin film and had a superconducting transition temperature of about 10.3 K. To couple terahertz radiation, the NbN microbridge (0.2 μm long and 2 μm wide) was integrated with a planar logarithmic-spiral antenna. The mixer chip was glued to an elliptical Si lens clamped tightly to a mixer block mounted on the 4.2 K plate of a liquid helium cryostat. The terahertz radiation was fed into the HEB device through the cryostat window made of a 0.5 mm thick HDPE. A band-pass mesh filter was mounted on the 4.2 K plate to minimize the direct detection effect [1]. We used a gas discharge laser irradiating at 3.8 THz H 2 0 line as a local oscillator (LO). The LO power was combined with a black body broadband radiation via Mylar beam splitter. Our receiver allows heterodyne detection with an intermediate frequency (IF) of a several gigahertz which dictates usage of a wideband SiGe low noise amplifier [2]. The receiver IF output signal was further amplified at room temperature and fed into a square-law power detector through a band-pass filter. The DSB receiver noise temperature was measured using a conventional Y-factor technique at IF of 1.25 GHz and band of 40 MHz. Using wideband amplifiers at both cryogenic and room temperature stages we have estimated IF bandwidth of the HEB mixers used. The obtained results strengthen the position of the HEB mixer as one of the most important tools for submillimeter astronomy. This device operates well above the energy gap (at frequencies above 1 THz) where performance of state-of-the-art SIS mixers starts to degrade. So, HEB mixers are expected to be a device of choice in astrophysical observations (ground-, aircraft- and space-based) at THz frequencies due to its excellent noise performance and low LO power requirements. The HEB mixers will be in operation on Millimetron Space Observatory. References 1. J. J. A. Baselmans, A. Baryshev, S. F. Reker, M. Hajenius, J. R. Gao, T. M. Klapwijk, Yu. Vachtomin, S. Maslennikov, S. Antipov, B. Voronov, and G. Gol'tsman, Appl. Phys. Lett., 86, 163503 (2005). 2. Sander Weinreb, Life Fellow, IEEE, Joseph C. Bardin, Student Member, IEEE, and Hamdi Mani, “Design of Cryogenic SiGe Low-Noise Amplifiers”, IEEE Transactions on Microwave Theory and Techniques, 55, 11, 2007.
|