toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Gershenzon, E. M.; Gol'tsman, G. N.; Zorin, M. A.; Karasik, B. S.; Trifonov, V. A. url  openurl
  Title Nonequilibrium and bolometric response of YBaCuO films in a resistive state to infrared low intensity radiation Type Conference Article
  Year 1994 Publication Council on Low-temp. Phys. Abbreviated Journal Council on Low-temp. Phys.  
  Volume Issue Pages 82-83  
  Keywords YBCO HTS HEB  
  Abstract  
  Address (down) Dubna  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Russian Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference Joint Inst. for Nuclear Research, Dubna (Russian Federation); 296 p; 1994; p. 82-83; 30. Conference on low-temperature physics; 30. Soveshchanie po fizike nizkikh temperatur; Dubna (Russian Federation); 6-8 Sep 1994  
  Notes Неравновесный и болометрический отклик YBaCuO пленок в резиотивном состоянии на инфракрасное лазерное излучение малой интенсивности Approved no  
  Call Number Serial 1632  
Permanent link to this record
 

 
Author Mohan, N.; Minaeva, O.; Gol'tsman, G. N.; Nasr, M. B.; Saleh, B. E.; Sergienko, A. V.; Teich, M. C. url  doi
openurl 
  Title Photon-counting optical coherence-domain reflectometry using superconducting single-photon detectors Type Journal Article
  Year 2008 Publication Opt. Express Abbreviated Journal Opt. Express  
  Volume 16 Issue 22 Pages 18118-18130  
  Keywords SSPD, SNSPD  
  Abstract We consider the use of single-photon counting detectors in coherence-domain imaging. Detectors operated in this mode exhibit reduced noise, which leads to increased sensitivity for weak light sources and weakly reflecting samples. In particular, we experimentally demonstrate the possibility of using superconducting single-photon detectors (SSPDs) for optical coherence-domain reflectometry (OCDR). These detectors are sensitive over the full spectral range that is useful for carrying out such imaging in biological samples. With counting rates as high as 100 MHz, SSPDs also offer a high rate of data acquisition if the light flux is sufficient.  
  Address (down) Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA. nm82@bu.edu  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1094-4087 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:18958090 Approved no  
  Call Number Serial 1407  
Permanent link to this record
 

 
Author Gerecht, E.; Musante, C. F.; Yngvesson, K. S.; Waldman, J.; Gol'tsman, G. N.; Yagoubov, P. A.; Voronov, B. M.; Gershenzon, E. M. url  openurl
  Title Optical coupling and conversion gain for NbN HEB mixer at THz frequencies Type Conference Article
  Year 1997 Publication Proc. 4-th Int. Semicond. Device Research Symp. Abbreviated Journal Proc. 4-th Int. Semicond. Device Research Symp.  
  Volume Issue Pages 47-50  
  Keywords NbN HEB mixers  
  Abstract  
  Address (down) Charlottesville, Virginia  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 1601  
Permanent link to this record
 

 
Author Finkel, M. I.; Maslennikov, S. N.; Gol'tsman, G. N. url  doi
openurl 
  Title The concept of the receiving complex for the “Millimetron” space radio telescope Type Journal Article
  Year 2007 Publication Radiophys. Quant. Electron. Abbreviated Journal Radiophys. Quant. Electron.  
  Volume 50 Issue 10-11 Pages 837-846  
  Keywords HEB, applications, Millimetron, VLBI  
  Abstract We consider the current status of research in the development of a submillimeter and far-infrared receiving instrument and propose promising solutions for the receivers of the spaceborne telescope “Millimetron,” which allow one to realize comprehensively the opportunities given by this international project administrated by the Astrospace Center of the P. N. Lebedev Physical Institute of the Russian Academy of Sciences.  
  Address (down)  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0033-8443 ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 411  
Permanent link to this record
 

 
Author Smirnov, A. V.; Larionov, P. A.; Finkel, M. I.; Maslennikov, S. N.; Voronov, B. M.; Gol'tsman, G. N. url  openurl
  Title NbZr films for THz phonon-cooled HEB mixers Type Conference Article
  Year 2008 Publication Proc. 19th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 19th Int. Symp. Space Terahertz Technol.  
  Volume Issue Pages 44-47  
  Keywords HEB, NbZr, material search  
  Abstract  
  Address (down)  
  Corporate Author Thesis  
  Publisher Place of Publication Groningen, Netherlands Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number Serial 577  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: