|
Akhmadishina, K. F., Bobrinetskiy, I. I., Komarov, I. A., Malovichko, A. M., Nevolin, V. K., Fedorov, G. E., et al. (2015). Fast-response biological sensors based on single-layer carbon nanotubes modified with specific aptamers. Semicond., 49(13), 1749–1753.
Abstract: The possibility of the fabrication of a fast-response biological sensor based on a composite of single-layer carbon nanotubes and aptamers for the specific detection of proteins is shown. The effect of modification of the surface of the carbon nanotubes on the selectivity and sensitivity of the sensors is investigated. It is shown that carboxylated nanotubes have a better selectivity for detecting thrombin.
|
|
|
Korneev, A. A. (2021). Superconducting NbN microstrip single-photon detectors. In I. Prochazka, M. Štefaňák, R. Sobolewski, & A. Gábris (Eds.), Proc. Quantum Optics and Photon Counting (Vol. 11771). SPIE.
Abstract: Superconducting Single-Photon Detectors (SSPD) invented two decades ago have evolved to a mature technology and have become devices of choice in the advanced applications of quantum optics, such as quantum cryptography and optical quantum computing. In these applications SSPDs are coupled to single-mode fibers and feature almost unity detection efficiency, negligible dark counts, picosecond timing jitter and MHz photon count rate. Meanwhile, there are great many applications requiring coupling to multi-mode fibers or free space. ‘Classical’ SSPDs with 100-nm-wide superconducting strip and covering area of about 100 µm2 are not suitable for further scaling due to degradation of performance and low fabrication yield. Recently we have demonstrated single-photon counting in micron-wide superconducting bridges and strips. Here we present our approach to the realization of practical photon-counting detectors of large enough area to be efficiently coupled to multi-mode fibers or free space. The detector is either a meander or a spiral of 1-µm-wide strip covering an area of 50x50 µm2. Being operated at 1.7K temperature it demonstrates the saturated detection efficiency (i.e. limited by the absorption in the detector) up to 1550 nm wavelength, about 10 ns dead time and timing jitter in range 50-100 ps.
|
|
|
Dryazgov, M., Semenov, A., Manova, N., Korneeva, Y., & Korneev, A. (2020). Modelling of normal domain evolution after single-photon absorption of a superconducting strip of micron width. In J. Phys.: Conf. Ser. (Vol. 1695, 012195 (1 to 4)).
Abstract: The present paper describes a modelling of normal domain evolution in superconducting strip of micron width using solving differential equations describing the temperature and current changes. The solving results are compared with experimental data. This comparison demonstrates the high accuracy of the model. In future, it is possible to employ this model for improvement of single photon detector based on micron-scale superconducting strips.
|
|
|
Manova, N. N., Simonov, N. O., Korneeva, Y. P., & Korneev, A. A. (2020). Developing of NbN films for superconducting microstrip single-photon detector. In J. Phys.: Conf. Ser. (Vol. 1695, 012116 (1 to 5)).
Abstract: We optimized NbN films on a Si substrate with a buffer SiO2 layer to produce superconducting microstrip single-photon detectors with saturated dependence of quantum efficiency (QE) versus normalized bias current. We varied thickness of films and observed the maximum QE saturation for device based on the thinner film with the lowest ratio RS300/RS20.
|
|
|
Polyakova, M. I., Korneev, A. A., & Semenov, A. V. (2020). Comparison single- and double- spot detection efficiencies of SSPD based to MoSi and NbN films. In J. Phys.: Conf. Ser. (Vol. 1695, 012146 (1 to 3)).
Abstract: In this work, we present results of quantum detector tomography of superconducting single photon detector (SSPD) based on MoSi film, and compare them with previously reported data on NbN. We find that for both materials hot spot interaction length coincides with the strip width, and the dependence of single and double-spot detection efficiencies on bias current are compatible with sufficiently large hot-spot size, approaching the strip width.
|
|
|
Vodolazov, D. Y., Manova, N. N., Korneeva, Y. P., & Korneev, A. A. (2020). Timing jitter in NbN superconducting microstrip single-photon detector. Phys. Rev. Applied, 14(4), 044041 (1 to 8).
Abstract: We experimentally study timing jitter of single-photon detection by NbN superconducting strips with width w ranging from 190 nm to 3μm. We find that timing jitter of both narrow (190 nm) and micron-wide strips is about 40 ps at currents where internal detection efficiency η saturates and it is close to our instrumental jitter. We also calculate intrinsic timing jitter in wide strips using the modified time-dependent Ginzburg-Landau equation coupled with a two-temperature model. We find that with increasing width the intrinsic timing jitter increases and the effect is most considerable at currents where a rapid growth of η changes to saturation. We relate it with complicated vortex and antivortex dynamics, which depends on a photon’s absorption site across the strip and its width. The model also predicts that at current close to depairing current the intrinsic timing jitter of a wide strip could be about ℏ/kBTc (Tc is a critical temperature of superconductor), i.e., the same as for a narrow strip.
|
|
|
Shein, K. V., Zarudneva, A. A., Emel’yanova, V. O., Logunova, M. A., Chichkov, V. I., Sobolev, A. S., et al. (2020). Superconducting microstructures with high impedance. Phys. Solid State, 62(9), 1539–1542.
Abstract: The transport properties of two types of quasi-one-dimensional superconducting microstructures were investigated at ultra-low temperatures: the narrow channels close-packed in the shape of meander, and the chains of tunneling contacts “superconductor-insulator-superconductor.” Both types of the microstructures demonstrated high value of high-frequency impedance and-or the dynamic resistance. The study opens up potential for using of such structures as current stabilizing elements with zero dissipation.
|
|
|
Korneeva, Y. P., Manova, N. N., Florya, I. N., Mikhailov, M. Y., Dobrovolskiy, O. V., Korneev, A. A., et al. (2020). Different single-photon response of wide and narrow superconducting MoxSi1−x strips. Phys. Rev. Applied, 13(2), 024011 (1 to 7).
Abstract: The photon count rate (PCR) of superconducting single-photon detectors made of MoxSi1−x films shaped as a 2-μm-wide strip and a 115-nm-wide meander strip line is studied experimentally as a function of the dc biasing current at different values of the perpendicular magnetic field. For the wide strip, a crossover current Icross is observed, below which the PCR increases with an increasing magnetic field and above which it decreases. This behavior contrasts with the narrow MoxSi1−x meander, for which no crossover current is observed, thus suggesting different photon-detection mechanisms in the wide and narrow strips. Namely, we argue that in the wide strip the absorbed photon destroys superconductivity locally via the vortex-antivortex mechanism for the emergence of resistance, while in the narrow meander superconductivity is destroyed across the whole strip line, forming a hot belt. Accordingly, the different photon-detection mechanisms associated with vortices and the hot belt determine the qualitative difference in the dependence of the PCR on the magnetic field.
|
|
|
Elmanov, I., Elmanova, A., Kovalyuk, V., An, P., & Goltsman, G. (2020). Integrated contra-directional coupler for NV-centers photon filtering. In Proc. 32-nd EMSS (pp. 354–360).
Abstract: We modelled an integrated optical contra-directional coupler on silicon nitride platform. Performance of the filter was studied depending on different parameters, including the grating period and the height of teeth of the Bragg grating near 637 nm operation wavelength. The obtained results can be used for a design and fabrication of quantum photonic integrated circuits with on-chip single-photon NV-centers in nanodiamonds.
|
|
|
Neroev, V. V., Iomdina, E. N., Khandzhyan, A. T., Khodzhabekyan, N. V., Sengaeva, M. D., Ivanova, A. V., et al. (2021). Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy. Vestn. Oftalmol., 137(3), 68–75.
Abstract: Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.
Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.
Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).
Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).
Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
|
|