Records |
Author |
Shcheslavskiy, V.; Morozov, P.; Divochiy, A.; Vakhtomin, Y.; Smirnov, K.; Becker, W. |
Title |
Erratum: “Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector” [Rev. Sci. Instrum. 87, 053117 (2016)] |
Type |
Miscellaneous |
Year |
2016 |
Publication |
Rev. Sci. Instrum. |
Abbreviated Journal |
Rev. Sci. Instrum. |
Volume |
87 |
Issue |
6 |
Pages |
069901 |
Keywords |
SSPD, SNSPD, TCSPC, jitter |
Abstract |
In the original paper1the Ref. 10 should be M. Sanzaro, N. Calandri, A. Ruggeri, C. Scarcella, G. Boso, M. Buttafava, and A. Tosi, Proc. SPIE9370, 93701T (2015). |
Address |
Becker & Hickl GmbH, Nahmitzer Damm 30, Berlin 12277, Germany |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0034-6748 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:27370512 |
Approved |
no |
Call Number |
|
Serial |
1810 |
Permanent link to this record |
|
|
|
Author |
Seleznev, V. A.; Divochiy, A. V.; Vakhtomin, Y. B.; Morozov, P. V.; Zolotov, P. I.; Vasil'ev, D. D.; Moiseev, K. M.; Malevannaya, E. I.; Smirnov, K. V. |
Title |
Superconducting detector of IR single-photons based on thin WSi films |
Type |
Conference Article |
Year |
2016 |
Publication |
J. Phys.: Conf. Ser. |
Abbreviated Journal |
J. Phys.: Conf. Ser. |
Volume |
737 |
Issue |
|
Pages |
012032 |
Keywords |
WSi SSPD, SNSPD, NEP |
Abstract |
We have developed the deposition technology of WSi thin films 4 to 9 nm thick with high temperature values of superconducting transition (Tc~4 K). Based on deposed films there were produced nanostructures with indicative planar sizes ~100 nm, and the research revealed that even on nanoscale the films possess of high critical temperature values of the superconducting transition (Tc~3.3-3.7 K) which certifies high quality and homogeneity of the films created. The first experiments on creating superconducting single-photon detectors showed that the detectors' SDE (system detection efficiency) with increasing bias current (I b) reaches a constant value of ~30% (for X=1.55 micron) defined by infrared radiation absorption by the superconducting structure. To enhance radiation absorption by the superconductor there were created detectors with cavity structures which demonstrated a practically constant value of quantum efficiency >65% for bias currents Ib>0.6-Ic. The minimal dark counts level (DC) made 1 s-1 limited with background noise. Hence WSi is the most promising material for creating single-photon detectors with record SDE/DC ratio and noise equivalent power (NEP). |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1742-6588 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1235 |
Permanent link to this record |
|
|
|
Author |
Moshkova, M.; Morozov, P.; Divochiy, A.; Vakhtomin, Y.; Smirnov, K. |
Title |
Large active area superconducting single photon detector |
Type |
Conference Article |
Year |
2019 |
Publication |
J. Phys.: Conf. Ser. |
Abbreviated Journal |
J. Phys.: Conf. Ser. |
Volume |
1410 |
Issue |
|
Pages |
012139 |
Keywords |
SSPD, SNSPD |
Abstract |
We present development of large active area superconducting single-photon detectors well coupled with standard 50 μm-core multi-mode fiber. The sensitive area of the SSPD is patterned using the photon-number-resolving design and occupies an area of 40×40 μm2. Using this approach, we have obtained excellent specifications: system detection efficiency of 47% measured using a 900 nm laser and low dark count rate of 100 cps. The main advantages of the approach presented are a very short dead time of the detector of 22 ns and FWHM jitter value of about 130 ps. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1742-6588 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1224 |
Permanent link to this record |
|
|
|
Author |
Moshkova, M.; Divochiy, A.; Morozov, P.; Vakhtomin, Y.; Antipov, A.; Zolotov, P.; Seleznev, V.; Ahmetov, M.; Smirnov, K. |
Title |
High-performance superconducting photon-number-resolving detectors with 86% system efficiency at telecom range |
Type |
Journal Article |
Year |
2019 |
Publication |
J. Opt. Soc. Am. B |
Abbreviated Journal |
J. Opt. Soc. Am. B |
Volume |
36 |
Issue |
3 |
Pages |
B20 |
Keywords |
NbN PNR SSPD, SNSPD |
Abstract |
The use of improved fabrication technology, highly disordered NbN thin films, and intertwined section topology makes it possible to create high-performance photon-number-resolving superconducting single-photon detectors (PNR SSPDs) that are comparable to conventional single-element SSPDs at the telecom range. The developed four-section PNR SSPD has simultaneously an 86±3% system detection efficiency, 35 cps dark count rate, ∼2 ns dead time, and maximum 90 ps jitter. An investigation of the PNR SSPD’s detection efficiency for multiphoton events shows good uniformity across sections. As a result, such a PNR SSPD is a good candidate for retrieving the photon statistics for light sources and quantum key distribution systems. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0740-3224 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1225 |
Permanent link to this record |
|
|
|
Author |
Moshkova, M. A.; Morozov, P. V.; Antipov, A. V.; Vakhtomin, Y. B.; Smirnov, K. V. |
Title |
High-efficiency multi-element superconducting single-photon detector |
Type |
Conference Article |
Year |
2021 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
11771 |
Issue |
|
Pages |
2-8 |
Keywords |
PNR SSPD, large active area, detection efficiency |
Abstract |
We present the result of the creation and investigation of the multi-element superconducting single photon detectors, which can recognize the number of photons (up to six) in a short pulse of the radiation at telecommunication wavelengths range. The best receivers coupled with single-mode fiber have the system quantum efficiency of ⁓85%. The receivers have a 100 ps time resolution and a few nanoseconds dead time that allows them to operate at megahertz counting rate. Implementation of the multi-element architecture for creation of the superconducting single photon detectors with increased sensitive area allows to create the high efficiency receivers coupled with multi-mode fibers and with preserving of the all advantages of superconducting photon counters. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Prochazka, I.; Štefaňák, M.; Sobolewski, R.; Gábris, A. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
Quantum Optics and Photon Counting |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1795 |
Permanent link to this record |
|
|
|
Author |
Moshkova, M. A.; Divochiy, A. V.; Morozov, P. V.; Antipov, A. V.; Vakhtomin, Yu. B.; Smirnov, K. V. |
Title |
Characterization of topologies of superconducting photon number resolving detectors |
Type |
Conference Article |
Year |
2019 |
Publication |
Proc. 8th Int. Conf. Photonics and Information Optics |
Abbreviated Journal |
Proc. 8th Int. Conf. Photonics and Information Optics |
Volume |
|
Issue |
|
Pages |
465-466 |
Keywords |
PNR SSPD |
Abstract |
Comparative analysis for different topologies of superconducting single-photon detectors with ability to resolve up to 4 photons in a short pulse of IR radiation has been carry out. It was developed the detector with a system detection efficiency of ~ 85 % at λ = 1550 nm. The possibility of using such detector to restore photon statistics of a pulsed radiation source was demonstrated. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
Russian |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
978-5-7262-2536-4 |
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
http://fioconf.mephi.ru/files/2018/12/FIO2019-Sbornik.pdf |
Approved |
no |
Call Number |
|
Serial |
1803 |
Permanent link to this record |
|
|
|
Author |
Morozov, P.; Lukina, M.; Shirmanova, M.; Divochiy, A.; Dudenkova, V.; Gol'tsman, G. N.; Becker, W.; Shcheslavskiy, V. I. |
Title |
Singlet oxygen phosphorescence imaging by superconducting single-photon detector and time-correlated single-photon counting |
Type |
Journal Article |
Year |
2021 |
Publication |
Opt. Lett. |
Abbreviated Journal |
Opt. Lett. |
Volume |
46 |
Issue |
6 |
Pages |
1217-1220 |
Keywords |
SSPD, SNSPD, applications |
Abstract |
This Letter presents, to the best of our knowledge, a novel optical configuration for direct time-resolved measurements of luminescence from singlet oxygen, both in solutions and from cultured cells on photodynamic therapy. The system is based on the superconducting single-photon detector, coupled to the confocal scanner that is modified for the near-infrared measurements. The recording of a phosphorescence signal from singlet oxygen at 1270 nm has been done using time-correlated single-photon counting. The performance of the system is verified by measuring phosphorescence from singlet oxygen generated by the photosensitizers commonly used in photodynamic therapy: methylene blue and chlorin e6. The described system can be easily upgraded to the configuration when both phosphorescence from singlet oxygen and fluorescence from the cells can be detected in the imaging mode. Thus, co-localization of the signal from singlet oxygen with the areas inside the cells can be done. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0146-9592 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
PMID:33720151 |
Approved |
no |
Call Number |
|
Serial |
1221 |
Permanent link to this record |
|
|
|
Author |
Divochiy, A.; Misiaszek, M.; Vakhtomin, Y.; Morozov, P.; Smirnov, K.; Zolotov, P.; Kolenderski, P. |
Title |
Single photon detection system for visible and infrared spectrum range |
Type |
Journal Article |
Year |
2018 |
Publication |
Opt. Lett. |
Abbreviated Journal |
Opt. Lett. |
Volume |
43 |
Issue |
24 |
Pages |
6085-6088 |
Keywords |
|
Abstract |
We demonstrate niobium nitride based superconducting single-photon detectors sensitive in the spectral range 452-2300 nm. The system performance was tested in a real-life experiment with correlated photons generated by means of spontaneous parametric downconversion, where one photon was in the visible range and the other was in the infrared range. We measured a signal to noise ratio as high as 4x10(4) in our detection setting. A photon detection efficiency as high as 64% at 1550 nm and 15% at 2300 nm was observed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0146-9592 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
https://arxiv.org/abs/1807.04273 |
Approved |
no |
Call Number |
|
Serial |
1227 |
Permanent link to this record |
|
|
|
Author |
Baeva, E. M.; Sidorova, M. V.; Korneev, A. A.; Smirnov, K. V.; Divochy, A. V.; Morozov, P. V.; Zolotov, P. I.; Vakhtomin, Y. B.; Semenov, A. V.; Klapwijk, T. M.; Khrapai, V. S.; Goltsman, G. N. |
Title |
Thermal properties of NbN single-photon detectors |
Type |
Journal Article |
Year |
2018 |
Publication |
Phys. Rev. Applied |
Abbreviated Journal |
Phys. Rev. Applied |
Volume |
10 |
Issue |
6 |
Pages |
064063 (1 to 8) |
Keywords |
NbN SSPD, SNSPD |
Abstract |
We investigate thermal properties of a NbN single-photon detector capable of unit internal detection efficiency. Using an independent calibration of the coupling losses, we determine the absolute optical power absorbed by the NbN film and, via resistive superconductor thermometry, the temperature dependence of the thermal resistance Z(T) of the NbN film. In principle, this approach permits simultaneous measurement of the electron-phonon and phonon-escape contributions to the energy relaxation, which in our case is ambiguous because of the similar temperature dependencies. We analyze Z(T) with a two-temperature model and impose an upper bound on the ratio of electron and phonon heat capacities in NbN, which is surprisingly close to a recent theoretical lower bound for the same quantity in similar devices. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2331-7019 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1226 |
Permanent link to this record |
|
|
|
Author |
Antipov, A. V.; Seleznev, V. A.; Vakhtomin, Y. B.; Morozov, P. V.; Vasilev, D. D.; Malevannaya, E. I.; Moiseev, K. M.; Smirnov, K. |
Title |
Investigation of WSi and NbN superconducting single-photon detectors in mid-IR range |
Type |
Conference Article |
Year |
2020 |
Publication |
IOP Conf. Ser.: Mater. Sci. Eng. |
Abbreviated Journal |
IOP Conf. Ser.: Mater. Sci. Eng. |
Volume |
781 |
Issue |
|
Pages |
012011 (1 to 5) |
Keywords |
WSi, NbN SSPD, SNSPD |
Abstract |
Spectral characteristics of WSi and NbN superconducting single-photon detectors with different surface resistance and width of nanowire strips have been investigated in the wavelength range of 1.3-2.5 μm. WSi structures with narrower strips demonstrated better performance for detection of single photons in longer wavelength range. The difference in normalized photon count rate for such structures reaches one order of magnitude higher in comparison with structures based on NbN thin films at 2.5 μm. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1757-899X |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1799 |
Permanent link to this record |