Nikogosyan, A. S., Martirosyan, R. M., Hakhoumian, A. A., Makaryan, A. H., Tadevosyan, V. R., Goltsman, G. N., et al. (2019). Effect of absorption on the efficiency of terahertz radiation generation in the metal waveguide partially filled with nonlinear crystal LiNbO3, DAST or ZnTe. J. Contemp. Phys., 54(1), 97–104.
Abstract: The influence of terahertz (THz) radiation absorption on the efficiency of generation of coherent THz radiation in the system ‘nonlinear-optical crystal partially filling the cross section of a rectangular metal waveguide’ has been investigated. The efficiency of the nonlinear frequency conversion of optical laser radiation to the THz range depends on the loss in the system and the fulfillment of the phase-matching (FM) condition in a nonlinear crystal. The method of partially filling of a metal waveguide with a nonlinear optical crystal is used to ensure phase matching. The phase matching is achieved by numerical determination of the thickness of the nonlinear crystal, that is the degree of partial filling of the waveguide. The attenuation of THz radiation caused by losses both in the metal walls of the waveguide and in the crystal was studied, taking into account the dimension of the cross section of the waveguide, the degree of partial filling, and the dielectric constant of the crystal. It is shown that the partial filling of the waveguide with a nonlinear crystal results in an increase in the efficiency of generation of THz radiation by an order of magnitude, owing to the decrease in absorption.
|
Nikoghosyan, A. S., Martirosyan, R. M., Hakhoumian, A. A., Makaryan, A. H., Tadevosyan, V. R., Goltsman, G. N., et al. (2018). Effect of absorption on the efficiency of THz radiation generation in a nonlinear crystal placed into a waveguide. Armenian J. Phys., 11(4), 257–262.
Abstract: The effect of THz radiation absorption on the efficiency of generation of coherent THz radiation in a nonlinear optical crystal placed into a metal rectangular waveguide is studied. The efficiency of the nonlinear conversion of optical laser radiation to the THz band is also a function of the phase-matching (PM) condition inside the nonlinear crystal. The method of partial filling of a metal waveguide with a nonlinear optical crystal is used to ensure phase matching. Phase matching was obtained by the proper choice of the thickness of the nonlinear crystal, namely the degree of partial filling of the waveguide. We have studied the THz radiation attenuation caused by the losses in both the metal walls of the waveguide and in the crystal, taking into account the dimension of the cross section of the waveguide, the degree of partial filling and its dielectric constant.
|
Maslennikov, S., Vachtomin, Y., Antipov, S., Smirnov, K., Kaurova, N., Grishina, E., et al. (2004). NbN HEB mixers for frequencies of 2.5 and 3.8 THz. In Proc. Tenth All-Russian sceintific conference of student-physicists and young sceintists (VNKSF-10). Moscow.
|
Maslennikov, S., Antipov, S., Shishkov, A., Svechnikov, S., Voronov, B., Smirnov, K., et al. (2002). NbN HEB mixer noise temperature measurements with hot/cold load mounted inside the helium cryostat at 300 GHz. In Proc. Int. Student Seminar on Microwave Appl. of Novel Physical Phenomena supported by IEEE. St.-Petersburg: LETI.
|
Maslennikov, S. N., Finkel, M. I., Antipov, S. V., Polyakov, S. L., Zhang, W., Ozhegov, R., et al. (2006). Spiral antenna coupled and directly coupled NbN HEB mixers in the frequency range from 1 to 70 THz. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 177–179). Paris, France.
Abstract: We investigate both antenna coupled and directly coupled HEB mixers at several LO frequencies within the range of 2.5 THz to 70 THz. H20 (2.5+10.7 THz), and CO2 (30 THz) gas discharge lasers are used as the local oscillators. The noise temperature of antenna coupled mixers is measured at LO frequencies of 2.5 THz, 3.8 THz, and 30 THz. The results for both antenna coupled and directly coupled mixer types are compared. The devices with in—plane dimensions of 5x5 ,um 2 are pumped by LO radiation at 10.7 THz. The directly coupled HEB demonstrates nearly flat dependence of responsivity on frequency in the range of 25+64 THz.
|
Krause, S., Mityashkin, V., Antipov, S., Gol’tsman, G., Meledin, D., Desmaris, V., et al. (2017). Reduction of phonon escape time for nbn hot electron bolometers by using gan buffer layers. IEEE Trans. Terahertz Sci. Technol., 7(1), 53–59.
Abstract: In this paper, we investigated the influence of the GaN buffer layer on the phonon escape time of phonon-cooled hot electron bolometers (HEBs) based on NbN material and compared our findings to conventionally employed Si substrate. The presented experimental setup and operation of the HEB close to the critical temperature of the NbN film allowed for the extraction of phonon escape time in a simplified manner. Two independent experiments were performed at GARD/Chalmers and MSPU on a similar experimental setup at frequencies of approximately 180 and 140 GHz, respectively, and have shown reproducible and consistent results. By fitting the normalized IF measurement data to the heat balance equations, the escape time as a fitting parameter has been deduced and amounts to 45 ps for the HEB based on Si substrate as in contrast to a significantly reduced escape time of 18 ps for the HEB utilizing the GaN buffer layer under the assumption that no additional electron diffusion has taken place. This study indicates a high phonon transmissivity of the NbN-to-GaN interface and a prospective increase of IF bandwidth for HEB made of NbN on GaN buffer layers, which is desirable for future THz HEB heterodyne receivers.
|
Krause, S., Mityashkin, V., Antipov, S., Gol'tsman, G., Meledin, D., Desmaris, V., et al. (2016). Study of IF bandwidth of NbN hot electron bolometers on GaN buffer layer using a direct measurement method. In Proc. 27th Int. Symp. Space Terahertz Technol. (pp. 30–32).
Abstract: In this paper, we present a reliable measurement method to study the influence of the GaN buffer layer on phonon-escape time in comparison with commonly used Si substrates and, in consequence, on the IF bandwidth of HEBs. One of the key aspects is to operate the HEB mixer at elevated bath temperatures close to the critical temperature of the NbN ultra-thin film, where contributions from electron-phonon processes and self-heating effects are relatively small, therefore IF roll-off will be governed by the phonon-escape.Two independent experiments were performed at GARD and MSPU on a similar experimental setup at frequencies of approximately 180 and 140 GHz, respectively, and have shown reproducible and consistent results. The entire IF chain was characterized by S-parameter measurements. We compared the measurement results of epitaxial NbN grown onto GaN buffer-layer with Tc of 12.5 K (4.5nm) with high quality polycrystalline NbN films on Si substrate with Tc of 10.5K (5nm) and observed a strong indication of an enhancement of phonon escape to the substrate by a factor of two for the NbN/GaN material combination.
|
Kaurova, N. S., Finkel, M. I., Maslennikov, S. N., Vahtomin, Y. B., Antipov, S. V., Smirnov, K. V., et al. (2004). Submillimeter mixer based on YBa2Cu3O7-x thin film. In Proc. 1-st conf. Fundamental problems of high temperature superconductivity (291). Moscow-Zvenigorod.
|
Jiang, L., Miao, W., Zhang, W., Li, N., Lin, Z. H., Yao, Q. J., et al. (2006). Characterization of a quasi-optical NbN superconducting HEB mixer. IEEE Trans. Microwave Theory Techn., 54(7), 2944–2948.
Abstract: In this paper, the performance of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer, cryogenically cooled by a close-cycled 4-K refrigerator, is thoroughly investigated at 300, 500, and 850 GHz. The lowest receiver noise temperatures measured at the respective three frequencies are 1400, 900, and 1350 K, which can go down to 659, 413, and 529 K, respectively, after correcting the loss and associated noise contribution of the quasi-optical system before the measured superconducting HEB mixer. The stability of the quasi-optical superconducting HEB mixer is also investigated here. The Allan variance time measured with a local oscillator pumping at 500 GHz and an IF bandwidth of 110 MHz is 1.5 s at the dc-bias voltage exhibiting the lowest noise temperature and increases to 2.5 s at a dc bias twice that voltage.
|
Jiang, L., Zhang, W., Yao, Q. J., Lin, Z. H., Li, J., Shi, S. C., et al. (2005). Characterization of a quasi-optical NbN superconducting hot-electron bolometer mixer. In Proc. PIERS (Vol. 1, pp. 587–590).
Abstract: In this paper, we report the performance of a quasi-optical NbN superconducting HEB (hot electron bolome-ter) mixer measured at 500 GHz. The quasi-optical NbN superconducting HEB mixer is cryogenically cooled bya 4-K close-cycled refrigerator. Its receiver noise temperature and conversion gain are thoroughly investigatedfor different LO pumping levels and dc biases. The lowest receiver noise temperature is found to be approxi-mately 1200 K, and reduced to about 445 K after correcting theloss of the measurement system. The stabilityof the mixer’s IF output power is also demonstrated.
|