|
Records |
Links |
|
Author ![sorted by Author field, descending order (down)](img/sort_desc.gif) |
Schroeder, E.; Mauskopf, P.; Pilyavsky, G.; Sinclair, A.; Smith, N.; Bryan, S.; Mani, H.; Morozov, D.; Berggren, K.; Zhu, D.; Smirnov, K.; Vakhtomin, Y. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
On the measurement of intensity correlations from laboratory and astronomical sources with SPADs and SNSPDs |
Type |
Conference Article |
|
Year |
2016 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
|
|
Volume |
9907 |
Issue |
|
Pages |
99070P (1 to 13) |
|
|
Keywords |
SPAD, NbN SSPD applications, SNSPD |
|
|
Abstract |
We describe the performance of detector modules containing silicon single photon avalanche photodiodes (SPADs) and superconducting nanowire single photon detectors (SNSPDs) to be used for intensity interferometry. The SPADs are mounted in fiber-coupled and free-space coupled packages. The SNSPDs are mounted in a small liquid helium cryostat coupled to single mode fiber optic cables which pass through a hermetic feed-through. The detectors are read out with microwave amplifiers and FPGA-based coincidence electronics. We present progress on measurements of intensity correlations from incoherent sources including gas-discharge lamps and stars with these detectors. From the measured laboratory performance of the correlation system, we estimate the sensitivity to intensity correlations from stars using commercial telescopes and larger existing research telescopes. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Malbet, F.; Creech-Eakman, M.J.; Tuthill, P.G. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Optical and Infrared Interferometry and Imaging V |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1809 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](img/sort_desc.gif) |
Sáysz, Wojciech; Guziewicz, Marek; Bar, Jan; Wegrzecki, Maciej; Grabiec, Piotr; Grodecki, Remigiusz; Wegrzecka, Iwona; Zwiller, Val; Milosnaya, Irina; Voronov, Boris; Gol’tsman, Gregory; Kitaygorsky, Jen; Sobolewski, Roman |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Superconducting NbN nanostructures for single photon quantum detectors |
Type |
Abstract |
|
Year |
2008 |
Publication |
Proc. 7-th Int. Conf. Ion Implantation and Other Applications of Ions and Electrons |
Abbreviated Journal |
Proc. 7-th Int. Conf. Ion Implantation and Other Applications of Ions and Electrons |
|
|
Volume |
|
Issue |
|
Pages |
160 |
|
|
Keywords |
SSPD, SNSPD |
|
|
Abstract |
Practical quantum systems such as quantum communication (QC) or quantum measurement systems require detectors with high speed, high sensitivity, high quantum efficiency (QE), and short deadtimes along with precise timing characteristics and low dark counts. Superconducting single photon detectors (SSPDs) based on ultrathin meander type NbN nanostripes (operated at T=2-5K) are a new and highly promising type of devices fulfilling above requirements. In this paper we present results of the SSPDs nanostructure technological optimization. The base for our detector is thin-film (4nm) NbN layer deposited on 350- P m-thick sapphire substrate The active element of the detector is a meander- nanostructure made of 4-nm-thick and 100-nm-wide NbN stripe, covering 10 u 10 P m 2 area with the filling factor ~0,5. The NbN superconducting films were deposited on sapphire substrates by DC reactive magnetron sputtering whereas the meander element of the detector was patterned by the direct electron-beam lithography followed by reactive-ion etching. To enhance the SSPD efficiency at Ȝ = 1.55 P m, we have performed an approach to increase the absorption of the detector by integrating it with optical resonant cavity. An optical microcavity optimized for absorption of 1.55 P m photons was designed as an one-mirror resonator consisting of a Ȝ/4 dielectric layer and a metallic mirror. The microcavity was deposited on the top of the NbN SSPD meander. The resonator was formed by the dielectric SiO 2 layer and metal mirror made of gold or palladium. Microcavity layers were deposited using a magnetron sputtering system. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1409 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](img/sort_desc.gif) |
Ryabchun, Sergey; Tong, Cheuk-yu Edward; Blundell, Raymond; Kimberk, Robert; Gol’tsman, Gregory |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Stabilisation of a terahertz hot-electron bolometer mixer with microwave feedback control |
Type |
Conference Article |
|
Year |
2007 |
Publication |
Proc. 18th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 18th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages |
193-198 |
|
|
Keywords |
waveguide NbN HEB mixers, Allan variance, stability |
|
|
Abstract |
We report on implementation of microwave feedback control loop to stabilise the performance of an HEB mixer receiver. It is shown that the receiver sensitivity increases by a factor of 4 over a 16-minute scan, and the corresponding Allan time increases up to 10 seconds, as opposed to an open loop value of 1 second. Our experiments also demonstrate that the receiver sensitivity is limited by the intermediate frequency chain. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1421 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](img/sort_desc.gif) |
Ryabchun, S.; Tong, C.-yu E.; Blundell, R.; Kimberk, R.; Gol’tsman, G. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Effect of microwave radiation on the stability of terahertz hot-electron bolometer mixers |
Type |
Conference Article |
|
Year |
2006 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
|
|
Volume |
6373 |
Issue |
|
Pages |
63730J (1 to 5) |
|
|
Keywords |
NbN HEB mixers, hot-electron bolometer mixers, stability, Allan variance, LO power fluctuations |
|
|
Abstract |
We report our studies of the effect of microwave radiation, with a frequency much lower than that corresponding to the energy gap of the superconductor, on the performance of the NbN hot-electron bolometer (HEB) mixer incorporated into a THz heterodyne receiver. It is shown that exposing the HEB mixer to microwave radiation does not result in a significant rise of the receiver noise temperature and degradation of the mixer conversion gain so long as the level of microwave power is small compared to the local oscillator drive. Hence the injection of a small, but controlled amount of microwave radiation enables active compensation of local oscillator power and coupling fluctuations which can significantly degrade the stability of HEB mixer receivers. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Anwar, M.; DeMaria, A.J.; Shur, M.S. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
Terahertz Physics, Devices, and Systems |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1441 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, descending order (down)](img/sort_desc.gif) |
Ryabchun, S.; Smirnov, A.; Pentin, I.; Vakhtomin, Yu.; Smirnov, K.; Kaurova, N.; Voronov, B.; Goltsman, G. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Superconducting single photon detector integrated with optical cavity |
Type |
Conference Article |
|
Year |
2011 |
Publication |
Proc. MLPLIT |
Abbreviated Journal |
Proc. MLPLIT |
|
|
Volume |
|
Issue |
|
Pages |
143-145 |
|
|
Keywords |
NbN SSPD, cavity |
|
|
Abstract |
|
|
|
Address |
Suzdal / Vladimir (Russia) |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Modern laser physics and laser-information technologies for science and manufacture |
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
1st international russian-chinese conference / youthschool-workshop |
|
|
Notes |
September 23-28, 2011 |
Approved |
no |
|
|
Call Number |
|
Serial |
1385 |
|
Permanent link to this record |