|
Semenov, A., Il'yin, K., Siegel, M., Smirnov, A., Pavlov, S., Richter, H., et al. (2006). Intermediate frequency bandwidth of a hot-electron mixer: Comparision with bolometric models. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 73–76). Paris, France.
|
|
|
Semenov, A., Richter, H., Smirnov, K., Voronov, B., Gol'tsman, G., & Hübers, H. - W. (2004). The development of terahertz superconducting hot-electron bolometric mixers. Supercond. Sci. Technol., 17(5), 436–439.
Abstract: We present recent advances in the development of NbN hot-electron bolometric (HEB) mixers for flying terahertz heterodyne receivers. Three important issues have been addressed: the quality of the source NbN films, the effect of the bolometer size on the spectral properties of different planar feed antennas, and the local oscillator (LO) power required for optimal operation of the mixer. Studies of the NbN films with an atomic force microscope indicated a surface structure that may affect the performance of the smallest mixers. Measured spectral gain and noise temperature suggest that at frequencies above 2.5 THz the spiral feed provides better overall performance than the double-slot feed. Direct measurements of the optimal LO power support earlier estimates made in the framework of the uniform mixer model.
|
|
|
Shelkovnikov, A., Grain, C., Nguyen, C. T., Butcher, R. J., Amy-Klein, A., & Chardonnet, C. (2001). 500-Hz two-photon Ramsey fringes with a SF6 beam: towards a new frequency standard in the 30-THz spectral region. Appl. Phys. B: Lasers and Optics, 73, 93–98.
|
|
|
Shitov, S. V., Inatani, J., Shan, W. - L., Takeda, M., Wang, Z., Uvarov, A. V., et al. (2008). Measurement of emissivity of the ALMA antenna panel at 840 GHz using NbN-based heterodyne SIS receiver. In Proc. 19th Int. Symp. Space Terahertz Technol. (pp. 263–266).
|
|
|
Shurakov, A., Tong, C. - Y. E., Blundell, R., Kaurova, N., Voronov, B., & Gol'tsman, G. (2013). Microwave stabilization of a HEB mixer in a pulse-tube cryocooler. IEEE Trans. Appl. Supercond., 23(3), 1501504.
Abstract: We report the results of our study of the stability of an 800 GHz hot electron bolometer (HEB) mixer cooled with a pulse-tube cryocooler. Pulse-tube cryocoolers introduce temperature fluctuations as well as mechanical vibrations at a frequency of ~1 Hz, both of which can cause receiver gain fluctuations at that frequency. In our system, the motor of the cryocooler was separated from the cryostat to minimize mechanical vibrations, leaving thermal effects as the dominant source of the receiver gain fluctuations. We measured root mean square temperature variations of the 4 K stage of ~7 mK. The HEB mixer was pumped by a solid state local oscillator at 810 GHz. The root mean square current fluctuations at the low noise operating point (1.50 mV, 56.5 μA) were ~0.12 μA, and were predominantly due to thermal fluctuations. To stabilize the bias current, microwave radiation was injected to the HEB mixer. The injected power level was set by a proportional-integral-derivative controller, which completely compensates for the bias current oscillations induced by the pulse-tube cryocooler. Significant improvement in the Allan variance of the receiver output power was obtained, and an Allan time of 5 s was measured.
|
|