Zwiller, V. <cc><81>ry, Blom, H., Jonsson, P., Panev, N., Jeppesen, S., Tsegaye, T., et al. (2001). Single quantum dots emit single photons at a time: Antibunching experiments. Appl. Phys. Lett., 78(17), 2476.
|
Zwiller, V., Aichele, T., Seifert, W., Persson, J., & Benson, O. (2003). Generating visible single photons on demand with single InP quantum dots. Appl. Phys. Lett., 82(10), 1509–1511.
|
Zhang, W., Khosropanah, P., Gao, J. R., Kollberg, E. L., Yngvesson, K. S., Bansal, T., et al. (2010). Quantum noise in a terahertz hot electron bolometer mixer. Appl. Phys. Lett., 96(11), 111113–(1–3).
Abstract: We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The beta-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.
|
Yates, S. J. C., Baryshev, A. M., Baselmans, J. J. A., Klein, B., & Güsten, R. (2009). Fast Fourier transform spectrometer readout for large arrays of microwave kinetic inductance detectors. Appl. Phys. Lett., 95(4), 3.
Abstract: Microwave kinetic inductance detectors have great potential for large, very sensitive detector arrays for use in, for example, submillimeter imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing ~1000 s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of fast Fourier transform spectrometer readout, showing no deterioration of the noise performance compared to the low noise analog mixing while allowing high multiplexing ratios.
|
Walther, C., Scalari, G., Faist, J., Beere, H., & Ritchie, D. (2006). Low frequency terahertz quantum cascade laser operating from 1.6 to 1.8 THz. Appl. Phys. Lett., 89, 231121(1–3).
Abstract: The authors report a GaAs/Al0.1Ga0.9As quantum cascade laser based on a bound-to-continuum transition optimized for low frequency operation. High tunability of the gain curve is achieved by the Stark effect and laser emission is measured between 1.6 and 1.8 THz. Pulsed mode operation up to 95 K and continuous wave operation up to 80 K are reported. The dynamical range in current is as high as 43%.
|
Terai, H., Miki, S., Yamashita, T., Makise, K., & Wang, Z. (2010). Demonstration of single-flux-quantum readout operation for superconducting single-photon detectors. Appl. Phys. Lett., 97(11), 3.
Abstract: A readout circuit using superconducting single-flux-quantum (SFQ) circuits has been developed to realize an independently addressable array of superconducting single-photon detectors (SSPDs). We tested the SFQ readout circuits by connecting with SSPDs. The error rates of readout circuits were below 10–5 for input signal amplitude of greater than 18.2 μA. Detection efficiencies (DEs) for single-photon incidents were measured both with and without the connection of a readout circuit. The observed DEs traced almost the same curves regardless of the connection of the readout circuit, except that the SSPD is likely to latch by connecting the readout circuit.
|
Tanner, M. G., Natarajan, C. M., Pottapenjara, V. K., O'Connor, J. A., Warburton, R. J., Hadfield, R. H., et al. (2010). Enhanced telecom wavelength single-photon detection with NbTiN superconducting nanowires on oxidized silicon. Appl. Phys. Lett., 96(22), 3.
Abstract: Superconducting nanowire single-photon detectors (SNSPDs) have emerged as a highly promising infrared single-photon detector technology. Next-generation devices are being developed with enhanced detection efficiency (DE) at key technological wavelengths via the use of optical cavities. Furthermore, new materials and substrates are being explored for improved fabrication versatility, higher DE, and lower dark counts. We report on the practical performance of packaged NbTiN SNSPDs fabricated on oxidized silicon substrates in the wavelength range from 830 to 1700 nm. We exploit constructive interference from the SiO2/Si interface in order to achieve enhanced front-side fiber-coupled DE of 23.2 % at 1310 nm, at 1 kHz dark count rate, with 60 ps full width half maximum timing jitter.
|
Stevens, M., Hadfield, R., Schwall, R., Nam, S. W., Mirin, R., & Gupta, J. (2006). Fast lifetime measurements of infrared emitters using a low-jitter superconduct- ing single-photon detector. Appl. Phys. Lett., 89, 031109.
|
Sprengers, J. P., Gaggero, A., Sahin, D., Jahanmirinejad, S., Frucci, G., Mattioli, F., et al. (2011). Waveguide superconducting single-photon detectors for integrated quantum photonic circuits. Appl. Phys. Lett., 99(18), 181110(1–3).
Abstract: The monolithic integration of single-photon sources, passive optical circuits, and single-photon detectors enables complex and scalable quantum photonic integrated circuits, for application in linear-optics quantum computing and quantum communications. Here, we demonstrate a key component of such a circuit, a waveguide single-photon detector. Our detectors, based on superconducting nanowires on GaAs ridge waveguides, provide high efficiency (~0%) at telecom wavelengths, high timing accuracy (~0 ps), and response time in the ns range and are fully compatible with the integration of single-photon sources, passive networks, and modulators.
|
Siddiqi, I., & Prober, D. E. (2004). Nb–Au bilayer hot-electron bolometers for low-noise THz heterodyne detection. Appl. Phys. Lett., 84(8), 1404.
Abstract: The sensitivity of present Nb diffusion-cooled hot-electron bolometer (HEB) mixers is not quantum limited, and can be improved by reducing the superconducting transition temperature TC. Lowering TC reduces thermal fluctuations, resulting in a decrease of the mixer noise temperature TM. However, lower TC mixers have reduced dynamic range and saturate more easily due to background noise. We present 30 GHz microwave measurements on a bilayer HEB system, Nb–Au, in which TC can be tuned with Au layer thickness to obtain the maximum sensitivity for a given noise background. These measurements are intended as a guide for the optimization of THz mixers. Using a Nb–Au mixer with TC = 1.6 K, we obtain TM = 50 K with 2 nW of local oscillator (LO) power. Good mixer performance is observed over a wide range of LO power and bias voltage and such a device should not exhibit saturation in a THz receiver.
|