|
Ozhegov, R., Elezov, M., Kurochkin, Y., Kurochkin, V., Divochiy, A., Kovalyuk, V., et al. (2014). Quantum key distribution over 300. In A. A. Orlikovsky (Ed.), Proc. SPIE (Vol. 9440, 1F (1 to 9)). SPIE.
Abstract: We discuss the possibility of polarization state reconstruction and measurement over 302 km by Superconducting Single- Photon Detectors (SSPDs). Because of the excellent characteristics and the possibility to be effectively coupled to singlemode optical fiber many applications of the SSPD have already been reported. The most impressive one is the quantum key distribution (QKD) over 250 km distance. This demonstration shows further possibilities for the improvement of the characteristics of quantum-cryptographic systems such as increasing the bit rate and the quantum channel length, and decreasing the quantum bit error rate (QBER). This improvement is possible because SSPDs have the best characteristics in comparison with other single-photon detectors. We have demonstrated the possibility of polarization state reconstruction and measurement over 302.5 km with superconducting single-photon detectors. The advantage of an autocompensating optical scheme, also known as “plugandplay” for quantum key distribution, is high stability in the presence of distortions along the line. To increase the distance of quantum key distribution with this optical scheme we implement the superconducting single photon detectors (SSPD). At the 5 MHz pulse repetition frequency and the average photon number equal to 0.4 we measured a 33 bit/s quantum key generation for a 101.7 km single mode ber quantum channel. The extremely low SSPD dark count rate allowed us to keep QBER at 1.6% level.
|
|
|
Ozhegov, R., Morozov, D., Maslennikov, S., Okunev, O., Smirnov, K., & Gol'tsman, G. (2004). Submillimeter wave range imaging system for registering human body radiation and finding out the things covered under clothes. In Proc. 3rd Int. exhibition and conf. Non-Destructive Testing Equipment and Devices. Moscow.
|
|
|
Ozhegov, R. V., Smirnov, A. V., Vakhtomin, Y. B., Smirnov, K. V., Divochiy, A. V., & Goltsman, G. N. (2009). Ultrafast superconducting bolometer receivers for terahertz applications. In Proc. PIERS (867). 777 Concord Avenue, Suite 207 Cambridge, MA 02138: The Electromagnetics Academy.
Abstract: The research by the group of Moscow State Pedagogical University into the hot-electron phenomena in thin superconducting films has led to the development of new types of detectors and their use both in fundamental and applied studies. In this paper, we present the results of testing the terahertz HEB receiver systems based on ultrathin (∼ 4 nm) NbN and MoRe detectors with a response time of 50 ps and 1 ns, respectively. We have developed three types of devices which differ in the way a terahertz signal is coupled to the detector and cover the following ranges: 0.3–3 THz, 0.1–30 THz and 25–70 THz. In the case of the receiving system optimized for 0.3–3 THz, the sensitive element (a strip of asuperconductor with planar dimensions of 0.2μm (length) by 1.7μm (width)) was integrated witha planar broadband log-spiral antenna. For additional focusing ofthe incident radiation a silicon hyperhemispherical lens was used. For the 0.1–30 THz receivingsystem, the sensitive element was patterned as parallel strips(2μm wide each) filling an area of 500×500μm2with a filling factor of 0.5. In the receivingsystem of this type we used direct coupling of the incident radiation to the sensitive element. Inthe 25–70 THz range (detector type 2/2a in Table 1) we used a square-shaped superconductingdetector with planar dimensions of 10×10μm2. Incident radiation was coupled to the detectorwith the use of a germanium hyperhemispherical lens.The response time of the above receiving systems is determined by the cooling rate of the hotelectrons in the film. That depends on the electron-phonon interaction time, which is less forultrathin NbN than in MoRe.
|
|
|
Ozhegov, R. V., Okunev, O. V., Gol’tsman, G. N., Filippenko, L. V., & Koshelets, V. P. (2009). Noise equivalent temperature difference of a superconducting integrated terahertz receiver. J. Commun. Technol. Electron., 54(6), 716–720.
Abstract: The dependence of the noise equivalent temperature difference (NETD) of a superconducting integrated receiver (SIR) on the receiver noise temperature and the inputsignal level has been investigated. An unprecedented NETD of 13±2 mK has been measured at a SIR noise temperature of 200 K, intermediate-frequency bandwidth of 4 GHz, and time constant of 1 s. With a decrease in the input signal, an improvement in the NETD is observed. This effect is explained by a reduction in the influence of the instabilities of the receiver power supply and the amplification circuit that occur when the input signal is decreased.
|
|
|
Ozhegov, R. V., Gorshkov, K. N., Vachtomin, Y. B., Smirnov, K. V., Finkel, M. I., Goltsman, G. N., et al. (2014). Terahertz imaging system based on superconducting heterodyne integrated receiver. In C. Corsi, & F. Sizov (Eds.), Proc. THz and Security Applications (pp. 113–125). Dordrecht: Springer Netherlands.
Abstract: The development of terahertz imaging instruments for security systems is on the cutting edge of terahertz technology. We are developing a THz imaging system based on a superconducting integrated receiver (SIR). An SIR is a new type of heterodyne receiver based on an SIS mixer integrated with a flux-flow oscillator (FFO) and a harmonic mixer which is used for phase-locking the FFO. Employing an SIR in an imaging system means building an entirely new instrument with many advantages compared to traditional systems.
In this project we propose a prototype THz imaging system using an 1 pixel SIR and 2D scanner. At a local oscillator frequency of 500 GHz the best noise equivalent temperature difference (NETD) of the SIR is 10 mK at an integration time of 1 s and a detection bandwidth of 4 GHz. The scanner consists of two rotating flat mirrors placed in front of the antenna consisting of a spherical primary reflector and an aspherical secondary reflector. The diameter of the primary reflector is 0.3 m. The operating frequency of the imaging system is 600 GHz, the frame rate is 0.1 FPS, the scanning area is 0.5 × 0.5 m2, the image resolution is 50 × 50 pixels, the distance from an object to the scanner was 3 m. We have obtained THz images with a spatial resolution of 8 mm and a NETD of less than 2 K.
|
|