|
Semenov, A., Richter, H., Hübers, H. - W., Smirnov, K., Voronov, B., & Gol'tsman, G. (2003). Development of terahertz superconducting hot-electron bolometer mixers. In Proc. 6th European Conf. Appl. Supercond. (Vol. 181, pp. 2960–2965).
Abstract: We present recent results of the development of phonon cooled hot-electron bolometric (HEB) mixers for airborne and balloon borne terahertz heterodyne receivers. Three iomportant issues have been addresses: the quality of NbN films the HEB mixers were made from, the spectral properties of the HEB mixers and the local oscillator power required for optical operation. Studies with an atomic force microscope indicate, that the performance of the HEB mixer might have been effected by the microstructure of the NbN film. Antenna gain and noise temperature were investigated at terahertz frequencies for a HEB embedded in either log-spiral or twin-slot feed antenna. Comparison suggests that at frequencies above 3 THz the spiral feed provides better overall performance. At 1.6 THz, a power of 2.5 µW was required from the local oscillator for optimal operation of the HEB mixer.
|
|
|
Semenov, A., Richter, H., Hübers, H. - W., Petrenko, D., Tretyakov, I., Ryabchun, S., et al. (2014). Optimization of the intermediate frequency bandwidth in the THz HEB mixers. In Proc. 25th Int. Symp. Space Terahertz Technol. (54).
Abstract: We report on the studies of the intermediate frequency (IF) bandwidth of quasi-optically coupled NbN hot-electron bolometer (HEB) mixers which are aimed at the optimization of the mixer performance at terahertz frequencies. Extension of the IF bandwidth due to the contribution of electron diffusion to the heat removal from NbN microbolometers has been already demonstrated for NbN HEBs at subterahertz frequencies. However, reducing the size of the microbolometer causes degradation of the noise temperature. Using in-situ multilayer manufacturing process we succeeded to improve the transparency of the contacts for electrons which go away from microbolometer to the metallic antenna. The improved transparency and hence coupling efficiency counterbalances the noise temperature degradation. HEB mixers were tested in a laboratory heterodyne receiver with a narrow-band cold filter which allowed us to eliminate direct detection. We used a local oscillator with a quantum cascade laser (QCL) at a frequency of 4.745 THz [1] which was developed for the H-Channel of the German Receiver for Astronomy at Terahertz frequencies (GREAT). Both the noise and gain bandwidth were measured in the IF range from 0.5 to 8 GHz using the hot-cold technique and preliminary calibrated IF analyzer with a tunable microwave filter. For optimized HEB geometry we found the noise bandwidth as large as 7 GHz. We compare our results with the conventional and the hot-spot mixer models and show that further extension of the IF bandwidth should be possible via improving the sharpness of the superconducting transition. The cross characterization of the HEB mixer was performed in the test bed of GREAT at the Max-Planck-Institut für Radioastronomie with the same QCL LO and delivered results which were consistent with the laboratory studies.
|
|
|
Semenov, A., Hübers, H. - W., Engel, A., & Gol’tsman, G. (2002). Superconducting quantum detector for far infrared astronomy. In J. Wolf, J. Farhoomand, & C. R. McCreight (Eds.), Far-IR, Sub-mm & MM Detector Technology Workshop (pp. 3–49). NASA CP. NASA.
Abstract: We present the concept of the superconducting quantum detector for astronomy. Response to a single absorbed photon appears due to successive formation of a normal spot and phase-slip-centres in a narrow strip carrying sub-critical supercurrent. The detector simultaneously has a moderate energy resolution and a variable cut-off wavelength depending on both the material used and operation conditions. We simulated performance of the background-limited direct detector having the 100-micrometer cut-off wavelength. Low dark count rate will allow to realise 10-21 W Hz-1/2 noise equivalent power at 4 K background radiation. The detection mechanism provides a moderate 1/20 energy resolution at 50-micrometer wavelength.
|
|
|
Semenov, A., Engel, A., Il'in, K., Gol'tsman, G., Siegel, M., & Hübers, H. - W. (2003). Ultimate performance of a superconducting quantum detector. Eur. Phys. J. Appl. Phys., 21(3), 171–178.
Abstract: We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.
|
|
|
Semenov, A. D., Il'in, K., Siegel, M., Smirnov, A., Pavlov, S., Richter, H., et al. (2006). Evidence of non-bolometric mixing in the bandwidth of a hot-electron bolometer. Supercond. Sci. Technol., 19(10), 1051–1056.
|
|