|
Gol'tsman, G. N., Karasik, B. S., Okunev, O. V., Dzardanov, A. L., Gershenzon, E. M., Ekstrom, H., et al. (1995). NbN hot electron superconducting mixers for 100 GHz operation. IEEE Trans. Appl. Supercond., 5(2), 3065–3068.
Abstract: NbN is a promising superconducting material for hot-electron superconducting mixers with an IF bandwidth larger than 1 GHz. In the 1OO GHz frequency range, the following parameters were obtained for 50 /spl Aring/ thick NbN films at 4.2 K: receiver noise temperature (DSB) /spl sim/1000 K; conversion loss /spl sim/10 dB; IF bandwidth /spl sim/1 GHz; and local oscillator power /spl sim/1 /spl mu/W. An increase of the critical current of the NbN film, increased working temperature, and a better mixer matching may allow a broader IF bandwidth up to 2 GHz, reduced conversion losses down to 3-5 dB and a receiver noise temperature (DSB) down to 200-300 K.
|
|
|
Gol’tsman, G., Okunev, O., Chulkova, G., Lipatov, A., Dzardanov, A., Smirnov, K., et al. (2001). Fabrication and properties of an ultrafast NbN hot-electron single-photon detector. IEEE Trans. Appl. Supercond., 11(1), 574–577.
Abstract: A new type of ultra-high-speed single-photon counter for visible and near-infrared wavebands based on an ultrathin NbN hot-electron photodetector (HEP) has been developed. The detector consists of a very narrow superconducting stripe, biased close to its critical current. An incoming photon absorbed by the stripe produces a resistive hotspot and causes an increase in the film’s supercurrent density above the critical value, leading to temporary formation of a resistive barrier across the device and an easily measurable voltage pulse. Our NbN HEP is an ultrafast (estimated response time is 30 ps; registered time, due to apparatus limitations, is 150 ps), frequency unselective device with very large intrinsic gain and negligible dark counts. We have observed sequences of output pulses, interpreted as single-photon events for very weak laser beams with wavelengths ranging from 0.5 /spl mu/m to 2.1 /spl mu/m and the signal-to-noise ratio of about 30 dB.
|
|
|
Tikhonov, V. V., Polyakova, O. N., Gol’tsman, G. N., Dzardanov, A. L., & Boyarskiy, D. A. (2008). Determination of dielectric properties of ore minerals in the microwave band. Radiophys. Quant. Electron., 51(12), 966–974.
Abstract: We consider a method for determining the complex dielectric permittivity of ore and nonmetal minerals in the microwave band of electromagnetic radiation. The results of measuring the reflectivity and transmittivity of chalcopyrite, magnetite, sphalerite, and labradorite samples in the frequency range 77–300 GHz are presented. A method for calculation of the complex dielectric permittivity of minerals on the basis of the obtained experimental data is proposed. The approximation formulas for calculation of the complex dielectric permittivity of the studied minerals are given.
|
|
|
Polyakova, O. N., Tikhonov, V. V., Dzardanov, A. L., Boyarskii, D. A., & Gol’tsman, G. N. (2008). Dielectric characteristics of ore minerals in a 10–40 GHz frequency range. Tech. Phys. Lett., 34(11), 967–970.
Abstract: A new approach to investigation of the complex dielectric permittivity of both nonmetallic and ore minerals in the microwave frequency range is proposed. Using this approach, data on the complex permittivity of sphalerite, magnetite, and labradorite in a 10–40 GHz frequency range have been obtained for the first time. A method is proposed for calculating the complex permittivity from experimentally measured frequency dependences of the reflection and transmission coefficients of a plane-parallel plate of a given mineral. Approximate expressions that can be used for calculations of the complex refractive index and permittivity of minerals are presented.
|
|
|
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., et al. (2001). Picosecond superconducting single-photon optical detector. Appl. Phys. Lett., 79(6), 705–707.
Abstract: We experimentally demonstrate a supercurrent-assisted, hotspot-formation mechanism for ultrafast detection and counting of visible and infrared photons. A photon-induced hotspot leads to a temporary formation of a resistive barrier across the superconducting sensor strip and results in an easily measurable voltage pulse. Subsequent hotspot healing in ∼30 ps time frame, restores the superconductivity (zero-voltage state), and the detector is ready to register another photon. Our device consists of an ultrathin, very narrow NbN strip, maintained at 4.2 K and current-biased close to the critical current. It exhibits an experimentally measured quantum efficiency of ∼20% for 0.81 μm wavelength photons and negligible dark counts.
|
|