|
Gousev, Y. P., Semenov, A. D., Pechen, E. V., Varlashkin, A. V., Nebosis, R. S., & Renk K. F. (1996). Coupling of terahertz radiation to a high-Т(с) superconducting hot electron bolometer mixer. Appl. Phys. Lett.,, 69, 691–693.
Abstract: We report on efficient coupling of THz radiation to a high-T(c) superconducting hot electron bolometer that is suitable for heterodyne detection. Our quasioptical system consisted of a planar self-complementary spiral antenna on a dielectric substrate clamped to an extended hyperhemispherical lens. The antenna was integrated into a co-planar line for broadband intermediate frequency matching. Measurements in the homodyne regime at a frequency of 2.5 THz showed a radiation pattern with a beam width of 1° and a coupling efficiency of 0.1. We measured, at an intermediate frequency of 1.5 GHz, an output noise temperature of'160 K and estimated for the device, operated in the heterodyne regime, a system noise temperature of 30 000 K. We also discuss possibilities of significant improvement of the sensitivity.
|
|
|
Floet D. W., Gao J. R., Klapwijk T. M., & de Korte P. A. J. (2000). Bias Dependence of the Thermal Time Constant in Nb Superconducting Diffusion-Cooled HEB Mixers. Appl. Phys. Lett., 77, 1719.
Abstract: We present an experimental study of the intermediate frequency bandwidth of a Nb diffusion-cooled hot-electron bolometer mixer for different bias voltages. The measurements show that the bandwidth increases with increasing voltage. Analysis of the data reveals that this effect is mainly caused by a decrease of the intrinsic thermal time of the mixer and that the effect of electrothermal feedback through the intermediate frequency circuit is small. The results are understood using a qualitative model, which takes into account the different effective diffusion constants in the normal and superconducting domains.
|
|
|
Santavicca, D. F., Reulet, B., Karasik, B. S., Pereverzev, S. V., Olaya, D., Gershenson, M. E., et al. (2010). Energy resolution of terahertz single-photon-sensitive bolometric detectors. Appl. Phys. Lett., 96(8), 083505-3.
Abstract: We report measurements of the energy resolution of ultrasensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single higher-frequency photon, where the absorbed energy of the pulse is equal to the photon energy. This technique allows precise calibration of the input coupling and avoids problems with unwanted background photons. Present devices have an intrinsic full-width at half-maximum energy resolution of approximately 23 THz, near the predicted value due to intrinsic thermal fluctuation noise.
|
|
|
An, Z., Chen, J. - C., Ueda, T., Komiyama, S., & Hirakawa, K. (2005). Infrared phototransistor using capacitively coupled two-dimensional electron gas layers. Appl. Phys. Lett., 86, 172106-3.
|
|
|
Stevens, M., Hadfield, R., Schwall, R., Nam, S. W., Mirin, R., & Gupta, J. (2006). Fast lifetime measurements of infrared emitters using a low-jitter superconduct- ing single-photon detector. Appl. Phys. Lett., 89, 031109.
|
|