Records |
Author |
Hübers, H.-W.; Semenov, A.; Richter, H.; Birk, Manfred; Krocka, Michael; Mair, Ulrich; Smirnov, K.; Gol'tsman, G.; Voronov, B. |
Title |
Terahertz heterodyne receiver with a hot-electron bolometer mixer |
Type |
Conference Article |
Year |
2002 |
Publication |
Proc. Far-IR, Sub-mm, and mm Detector Technology Workshop |
Abbreviated Journal |
Proc. Far-IR, Sub-mm, and mm Detector Technology Workshop |
Volume |
|
Issue |
|
Pages |
|
Keywords |
NbN HEB mixers |
Abstract |
During the past decade major advances have been made regarding low noise mixers for terahertz (THz) heterodyne receivers. State of the art hot-electron-bolometer (HEB) mixers have noise temperatures close to the quantum limit and require less than a µW power from the local oscillator (LO). The technology is now at a point where the performance of a practical receiver employing such mixer, rather than the figures of merit of the mixer itself, are of major concern. We have incorporated a phonon-cooled NbN HEB mixer in a 2.5 THz heterodyne receiver and investigated the performance of the receiver. This yields important information for the development of heterodyne receivers such as GREAT (German receiver for astronomy at THz frequencies aboard SOFIA)[1] and TELIS (Terahertz limb sounder), a balloon borne heterodyne receiver for atmospheric research [2]. Both are currently under development at DLR. |
Address |
Monterey, CA, USA |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
Wold, J.; Davidson, J. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
|
Notes |
4 pages; Unconfirmed but cited in https://kups.ub.uni-koeln.de/1622/1/bedorf.pdf; There is a Program of the Workshop: https://www.yumpu.com/en/document/view/7411055/far-ir-submm-mm-detector-technology-workshop-sofia-usra (there is no title of this article in the Program); There is also identical publication in Proc. ISSTT (Serial: 332, “A broadband terahertz heterodyne receiver with an NbN HEB mixer”). |
Approved |
no |
Call Number |
|
Serial |
1829 |
Permanent link to this record |
|
|
|
Author |
Sidorova, M.; Semenov, A.; Hübers, H.-W.; Kuzmin, A.; Doerner, S.; Ilin, K.; Siegel, M.; Charaev, I.; Vodolazov, D. |
Title |
Timing jitter in photon detection by straight superconducting nanowires: Effect of magnetic field and photon flux |
Type |
Journal Article |
Year |
2018 |
Publication |
Phys. Rev. B |
Abbreviated Journal |
Phys. Rev. B |
Volume |
98 |
Issue |
13 |
Pages |
134504 (1 to 14) |
Keywords |
SNSPD, NbN namowires |
Abstract |
We studied the effects of the external magnetic field and photon flux on timing jitter in photon detection by straight superconducting NbN nanowires. At two wavelengths 800 and 1560 nm, statistical distribution in the appearance times of photon counts exhibits Gaussian shape at small times and an exponential tail at large times. The characteristic exponential time is larger for photons with smaller energy and increases with external magnetic field while variations in the Gaussian part of the distribution are less pronounced. Increasing photon flux drives the nanowire from the discrete quantum detection regime to the uniform bolometric regime that averages out fluctuations of the total number of nonequilibrium electrons created by the photon and drastically reduces jitter. The difference between standard deviations of Gaussian parts of distributions for these two regimes provides the measure for the strength of electron-number fluctuations; it increases with the photon energy. We show that the two-dimensional hot-spot detection model explains qualitatively the effect of magnetic field. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2469-9950 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1842 |
Permanent link to this record |
|
|
|
Author |
Semenov, A. D.; Sergeev, A. V.; Kouminov, P.; Goghidze, I. G.; Heusinger, M. A.; Nebosis, R. S.; Gol'tsman, G. N.; Gershenzon, E. M.; Renk, K. F. |
Title |
Transparency of YBCO film/substrate interfaces for thermal phonons determined by photoresponse measurements |
Type |
Conference Article |
Year |
1993 |
Publication |
Proc. 1st European Conf. on Appl. Supercond. |
Abbreviated Journal |
Proc. 1st European Conf. on Appl. Supercond. |
Volume |
2 |
Issue |
|
Pages |
1443-1446 |
Keywords |
YBCO HTS detectors |
Abstract |
Direct measurements of the thermal boundary resistance were performed by means of the stationary method. In this approach the temperature of an electrically heated film is controlled by its dc resistance while an additional film on the same substrate is used as a thermometer monitoring substrate temperature. The temperature field in the substrate is then calculated to deduce the Kapitza temperature step at the interface between the heated strip and the substrate. The main statement of all afore-said papers is that experimental values of the thermal boundary resistance are too large to be explained by the acoustic mismatch model. In this paper we investigate transparency of YBaCuO film/substrate interfaces for thermal phonons by means of photoresponse measurements. We show that our data are in reasonable agreement with the acoustic mismatch theory. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
Freyhardt, H. C. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
3-88355-197-X |
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
1st European conference on applied superconductivity |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1661 |
Permanent link to this record |
|
|
|
Author |
Schubert, J.; Semenov, A.; Hübers, H.-W.; Gol'tsman, G.; Schwaab, G.; Voronov, B.; Gershenzon, E. |
Title |
Broad-band terahertz NbN hot-electron bolometric mixer |
Type |
Conference Article |
Year |
1999 |
Publication |
Inst. Phys. Conf. |
Abbreviated Journal |
Inst. Phys. Conf. |
Volume |
167 |
Issue |
|
Pages |
663-666 |
Keywords |
NbN HEB mixers |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
4th Europ. Conf. on Appl. Superconductivity, Barcelona, Spain, 14-17 September 1999 |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1578 |
Permanent link to this record |
|
|
|
Author |
Huebers, H.-W.; Semenov, A.; Schubert, J.; Gol’tsman, G. N.; Voronov, B. M.; Gershenzon, E. M.; Krabbe, A.; Roeser, H.-P. |
Title |
NbN hot-electron bolometer as THz mixer for SOFIA |
Type |
Conference Article |
Year |
2000 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
4014 |
Issue |
|
Pages |
195-202 |
Keywords |
NbN HEB mixers, airborne, stratospheric observatory, SOFIA |
Abstract |
Heterodyne receivers for applications in astronomy need quantum limited sensitivity. We have investigated phonon- cooled NbN hot electron bolometric mixers in the frequency range from 0.7 THz to 5.2 THz. The devices were 3.5 nm thin films with an in-plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The best measured DSB receiver noise temperatures are 1300 K (0.7 THz), 2000 K (1.4 THz), 2100 K (1.6 THz), 2600 K (2.5 THz), 4000 K (3.1 THz), 5600 K (4.3 THz), and 8800 K (5.2 THz). The sensitivity fluctuation, the long term stability, and the antenna pattern were measured. The results demonstrate that this mixer is very well suited for GREAT, the German heterodyne receiver for SOFIA. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Melugin, R.K.; Roeser, H.-P. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Airborne Telescope Systems |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1554 |
Permanent link to this record |
|
|
|
Author |
Gershenzon, E. M.; Gol’tsman, G. N.; Sergeev, A.; Semenov, A. D. |
Title |
Picosecond response of YBaCuO films to electromagnetic radiation |
Type |
Conference Article |
Year |
1990 |
Publication |
Proc. European Conf. High-Tc Thin Films and Single Crystals |
Abbreviated Journal |
Proc. European Conf. High-Tc Thin Films and Single Crystals |
Volume |
|
Issue |
|
Pages |
457-462 |
Keywords |
YBCO HTS detectors |
Abstract |
Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
Gorzkowski, W.; Gutowski, M.; Reich, A.; Szymczak, H. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
European Conference , Ustroń, Poland , 30 Sept – 4 Oct 1989 |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1695 |
Permanent link to this record |
|
|
|
Author |
Hübers, Heinz-Wilhelm; Semenov, A.; Richter, H.; Smirnov, K.; Gol'tsman, G.; Voronov, B. |
Title |
Phonon cooled far-infrared hot electron bolometer mixer |
Type |
Abstract |
Year |
2002 |
Publication |
NASA/ADS |
Abbreviated Journal |
NASA/ADS |
Volume |
|
Issue |
|
Pages |
|
Keywords |
NbN HEB mixers |
Abstract |
Heterodyne receivers for applications in astronomy need quantum-limited sensitivity. At frequencies above 1.4 THz superconducting hot electron bolometers (HEB) can be used to achieve this goal. We present results of the development of a quasi-optical phonon-cooled NbN HEB mixer for GREAT, the German heterodyne receiver for SOFIA. Different mixers with logarithmic spiral and double slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern at several frequencies between 0.7 THz and 5.2 THz. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 16 dB. The response of the mixer was linear up to 400 K load temperature. This performance was verified by measuring an emission line of methanol at 2.5 THz. The results demonstrate that the NbN HEB is very well suited as a mixer for FIR heterodyne receivers. |
Address |
Monterey, CA |
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Far-IR, Sub-mm & MM Detector Technology Workshop, 1-3 April 2002 |
Notes |
id.37 |
Approved |
no |
Call Number |
|
Serial |
1534 |
Permanent link to this record |
|
|
|
Author |
Hoogeveen, R. W. M.; Yagoubov, P. A.; Maurellis, A.; Koshelets, V. P.; Shitov, S. V.; Mair, U.; Krocka, M.; Wagner, G.; Birk, M.; Huebers, H.-W.; Richter, H.; Semenov, A.; Gol’tsman, G. N.; Voronov, B. M.; Ellison, B.N.; Kerridge, B.J.; Matheson, D. N.; Alderman, B.; Harman, M.; Siddans, R.; Reburn, J. |
Title |
New cryogenic heterodyne techniques applied in TELIS: the balloonborne THz and submillimeter limb sounder for atmospheric research |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
5152 |
Issue |
|
Pages |
347-355 |
Keywords |
TELIS, limb sounder, heterodyne detection, terahertz, sub millimeter, cryogenic, limb sounding, balloon borne, atmospheric research |
Abstract |
We present a design concept for a new state-of-the-art balloon borne atmospheric monitor that will allow enhanced limb sounding of the Earth’s atmosphere within the submillimeter and far-infrared wavelength spectral range: TELIS, TErahertz and submm LImb Sounder. The instrument is being developed by a consortium of major European institutes that includes the Space Research Organization of the Netherlands (SRON), the Rutherford Appleton Laboratory (RAL) will utilize state-of-the-art superconducting heterodyne technology and is designed to be a compact, lightweight instrument cpaable of providing broad spectral coverage, high spectral resolution and long flight duration ( 24 hours duration during a single flight campaign). The combination of high sensitivity and extensive flight duration will allow evaluation of the diurnal variation of key atmospheric constitutenets sucyh as OH, HO2, ClO, BrO togehter will onger lived constituents such as O3, HCL and N2O. Furthermore, TELIS will share a common balloon platform to that of the MIPAS-B Fourier Transform Spectrometer, developed by the Institute of Meteorology and Climate research of the over an extended spectral range. The combination of the TELIS and MIPAS instruments will provide atmospheric scientists with a very powerful observational tool. TELIS will serve as a testbed for new cryogenic heterodyne detection techniques, and as such it will act as a prelude to future spaceborne instruments planned by the European Space Agency (ESA). |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Strojnik, M. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Infrared Spaceborne Remote Sensing XI |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1508 |
Permanent link to this record |
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N.; Semenov, A. D.; Sergeev, A. V. |
Title |
Heating of electrons in resistive state of superconducting films. Detectors, mixers and switches |
Type |
Conference Article |
Year |
1992 |
Publication |
Progress in High Temperature Superconductivity |
Abbreviated Journal |
Progress in High Temperature Superconductivity |
Volume |
32 |
Issue |
|
Pages |
190-195 |
Keywords |
superconducting films, heating of electrons |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
International Conference on High Temperature Superconductivity and Localization Phenomena , Moscow, Russia , 11 – 15 May 1991 |
Notes |
https://books.google.co.kr/books?hl=en&lr=&id=uCI0DwAAQBAJ&oi=fnd&pg=PA190&ots=z7WGjXYWr4&sig=TQ6G6dKsmcj4faYe1ZLw_BFmps8 |
Approved |
no |
Call Number |
|
Serial |
1666 |
Permanent link to this record |
|
|
|
Author |
Yagoubov, P.; Hübers, H.-W.; Gol’tsman, G.; Semenov, A.; Gao, J.; Hoogeveen, R.; de Graauw, T.; Birk, M.; Selig, A.; de Korte, P. |
Title |
Hot-electron bolometer mixers – technology for far-infrared heterodyne instruments in future atmospheric chemistry missions |
Type |
Conference Article |
Year |
2001 |
Publication |
Proc. 3rd Int. Symp. Submillimeter Wave Earth Observation From Space |
Abbreviated Journal |
Proc. 3rd Int. Symp. Submillimeter Wave Earth Observation From Space |
Volume |
|
Issue |
|
Pages |
57-69 |
Keywords |
HEB mixers |
Abstract |
|
Address |
Delmenhorst |
Corporate Author |
|
Thesis |
|
Publisher |
Logos-Verlag |
Place of Publication |
|
Editor |
Buehler, S.; Berlin |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
3-89722-700-2 |
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
International Symposium on Submillimeter Wave Earth Observation from Space, ISSMWEOS01 |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1549 |
Permanent link to this record |
|
|
|
Author |
Semenov, A. D.; Hübers, H.-W.; Gol’tsman, G. N.; Smirnov, K. |
Title |
Superconducting quantum detector for astronomy and X-ray spectroscopy |
Type |
Conference Article |
Year |
2002 |
Publication |
Proc. Int. Workshop on Supercond. Nano-Electronics Devices |
Abbreviated Journal |
Proc. Int. Workshop on Supercond. Nano-Electronics Devices |
Volume |
|
Issue |
|
Pages |
201-210 |
Keywords |
NbN SSPD, SNSPD, SQD, superconducting quantum detectors, X-ray spectroscopy |
Abstract |
We propose the novel concept of ultra-sensitive energy-dispersive superconducting quantum detectors prospective for applications in astronomy and X-ray spectroscopy. Depending on the superconducting material and operation conditions, such detector may allow realizing background limited noise equivalent power 10−21 W Hz−1/2 in the terahertz range when exposed to 4-K background radiation or counting of 6-keV photon with almost 10—4 energy resolution. Planar layout and relatively simple technology favor integration of elementary detectors into a detector array. |
Address |
Naples, Italy |
Corporate Author |
|
Thesis |
|
Publisher |
Springer |
Place of Publication |
Boston, MA |
Editor |
Pekola, J.; Ruggiero, B.; Silvestrini, P. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
978-1-4615-0737-6 |
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
International Workshop on Superconducting Nano-Electronics Devices, May 28-June 1, 2001 |
Notes |
|
Approved |
no |
Call Number |
semenov2002superconducting |
Serial |
1525 |
Permanent link to this record |
|
|
|
Author |
Huebers, H.-W.; Semenov, A.; Richter, H.; Birk, M.; Krocka, M.; Mair, U.; Smirnov, K.; Gol’tsman, G. N.; Voronov, B. M. |
Title |
Superconducting hot electron bolometer as mixer for far-infrared heterodyne receivers |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
4855 |
Issue |
|
Pages |
395-401 |
Keywords |
NbN HEB mixers |
Abstract |
Heterodyne receivers for applications in astronomy need quantum limited sensitivity. In instruments which are currently under development for SOFIA or Herschel superconducting hot electron bolometers (HEB) will be used to achieve this goal at frequencies above 1.4 THz. We present results of the development of a phonon-cooled NbN HEB mixer for GREAT, the German Receiver for Astronomy at Terahertz Frequencies, which will be flown aboard SOFIA. The mixer is a small superconducting bridge incorporated in a planar feed antenna and a hyperhemispherical lens. Mixers with logarithmic-spiral and double-slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 17 dB. The response of the mixer was linear up to 400 K load temperature. The performance was verified by measuring an emission line of methanol at 2.5 THz. The measured linewidth is in good agreement with the linewidth deduced from pressure broadening measurements at millimeter wavelength. The results demonstrate that the NbN HEB is very well suited as a mixer for far-infrared heterodyne receivers. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
SPIE |
Place of Publication |
Tucson, USA |
Editor |
Phillips, T. G.; Zmuidzinas, J. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
Presented at the Society of Photo-Optical Instrumentation Engineers (SPIE) Conference |
Abbreviated Series Title |
|
Series Volume |
4855 |
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Millimeter and Submillimeter Detectors for Astronomy |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
335 |
Permanent link to this record |
|
|
|
Author |
Hubers, H.-W.; Semenov, A.; Richter, H.; Schwarz, M.; Gunther, B.; Smirnov, K.; Gol’tsman, G.; Voronov, B. |
Title |
Heterodyne receiver for 3-5 THz with hot-electron bolometer mixer |
Type |
Conference Article |
Year |
2004 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
5498 |
Issue |
|
Pages |
579-586 |
Keywords |
NbN HEB mixers |
Abstract |
Heterodyne receivers for applications in astronomy and planetary research need quantum limited sensitivity. In instruments which are currently build for SOFIA and Herschel superconducting hot electron bolometers (HEB) will be used to achieve this goal at frequencies above 1.4 THz. The local oscillator and the mixer are the most critical components for a heterodyne receiver operating at 3-5 THz. The design and performance of an optically pumped THz gas laser optimized for this frequency band will be presented. In order to optimize the performance for this frequency hot electron bolometer mixers with different in-plane dimensions and logarithmic-spiral feed antennas have been investigated. Their noise temperatures and beam patterns were measured. Above 3 THz the best performance was achieved with a superconducting bridge of 2.0 x 0.2 μm2 incorporated in a logarithmic spiral antenna. The DSB noise temperatures were 2700 K, 4700 K and 6400 K at 3.1 THz, 4.3 THz and 5.2 THz, respectively. The results demonstrate that the NbN HEB is very well suited as a mixer for THz heterodyne receivers up to at least 5 THz. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
SPIE |
Place of Publication |
|
Editor |
Zmuidzinas, J.; Holland, W.S.; Withington, S. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Millimeter and Submillimeter Detectors for Astronomy II |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1483 |
Permanent link to this record |
|
|
|
Author |
Shcherbatenko, M.; Lobanov, Y.; Semenov, A.; Kovalyuk, V.; Korneev, A.; Ozhegov, R.; Kaurova, N.; Voronov, B.; Goltsman, G. |
Title |
Coherent detection of weak signals with superconducting nanowire single photon detector at the telecommunication wavelength |
Type |
Conference Article |
Year |
2017 |
Publication |
Proc. SPIE |
Abbreviated Journal |
Proc. SPIE |
Volume |
10229 |
Issue |
|
Pages |
0G (1 to 12) |
Keywords |
SSPD mixer, SNSPD, coherent detection, weak signal detection, superconducting nanostructures |
Abstract |
Achievement of the ultimate sensitivity along with a high spectral resolution is one of the frequently addressed problems, as the complication of the applied and fundamental scientific tasks being explored is growing up gradually. In our work, we have investigated performance of a superconducting nanowire photon-counting detector operating in the coherent mode for detection of weak signals at the telecommunication wavelength. Quantum-noise limited sensitivity of the detector was ensured by the nature of the photon-counting detection and restricted by the quantum efficiency of the detector only. Spectral resolution given by the heterodyne technique and was defined by the linewidth and stability of the Local Oscillator (LO). Response bandwidth was found to coincide with the detector’s pulse width, which, in turn, could be controlled by the nanowire length. In addition, the system noise bandwidth was shown to be governed by the electronics/lab equipment, and the detector noise bandwidth is predicted to depend on its jitter. As have been demonstrated, a very small amount of the LO power (of the order of a few picowatts down to hundreds of femtowatts) was required for sufficient detection of the test signal, and eventual optimization could lead to further reduction of the LO power required, which would perfectly suit for the foreseen development of receiver matrices and the need for detection of ultra-low signals at a level of less-than-one-photon per second. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
Spie |
Place of Publication |
|
Editor |
Prochazka, I.; Sobolewski, R.; James, R.B. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Photon counting applications |
Notes |
|
Approved |
no |
Call Number |
10.1117/12.2267724 |
Serial |
1201 |
Permanent link to this record |
|
|
|
Author |
Gol’tsman, G. N.; Semenov, A. D.; Sergeev, A. V.; Aksaev, E. E.; Gogidze, I. G.; Gershenzon, E. M. |
Title |
Electron-phonon interaction in thin YBaCuO films and fast detectors |
Type |
Conference Article |
Year |
1993 |
Publication |
Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences |
Abbreviated Journal |
Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences |
Volume |
112 |
Issue |
|
Pages |
184-185 |
Keywords |
YBCO HTS detectors |
Abstract |
The thin. YBaCuO film response to laser and submillimeter radiation demonstrates the picosecond nonequilibrium peak on the nanosecond bolometric background. Experimental data give an evidence for the spectral dependence of picosecond photoresponse probably due to a poor efficiency of electron multiplication processes. Presented results prove an availability of fast YBaCuO thin film detector. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
Meissner, M.; Pohl, R. O. |
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference ![sorted by Conference field, ascending order (up)](img/sort_asc.gif) |
Seventh International Conference, Cornell University, Ithaca, New York, August 3-7, 1992 |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1662 |
Permanent link to this record |