Records |
Author |
Tong, C.-Y.E.; Meledin, D.V.; Marrone, D.P.; Paine, S.N.; Gibson, H.; Blundell, R. |
Title |
Near field vector beam measurements at 1 THz |
Type |
Journal Article |
Year |
2003 |
Publication |
IEEE Microw. Compon. Lett. |
Abbreviated Journal |
|
Volume |
13 |
Issue |
6 |
Pages |
235-237 |
Keywords |
HEB, mixer, waveguide, LO power, local oscillator power, saturation effect, dynamic range |
Abstract |
We have performed near-field vector beam measurements at 1.03 THz to characterize and align the receiver optics of a superconducting receiver. The signal source is a harmonic generator mounted on an X-Y translation stage. We model the measured two-dimensional complex beam pattern by a fundamental Gaussian mode, from which we derive the position of the beam center, the beam radius and the direction of propagation. By performing scans in the planes separated by 400 mm, we have confirmed that our beam pattern measurements are highly reliable. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1531-1309 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ lobanovyury @ |
Serial |
574 |
Permanent link to this record |
|
|
|
Author |
Zhang, J.; Pearlman, A.; Slysz, W.; Verevkin, A.; Sobolewski, R.; Wilsher, K.; Lo, W.; Okunev, O.; Korneev, A.; Kouminov, P.; Chulkova, G.; Gol’tsman, G. N. |
Title |
A superconducting single-photon detector for CMOS IC probing |
Type |
Conference Article |
Year |
2003 |
Publication |
Proc. 16-th LEOS |
Abbreviated Journal |
Proc. 16-th LEOS |
Volume |
2 |
Issue |
|
Pages |
602-603 |
Keywords |
NbN SSPD, SNSPD |
Abstract |
In this paper, a novel, time-resolved, NbN-based, superconducting single-photon detector (SSPD) has been developed for probing CMOS integrated circuits (ICs) using photon emission timing analysis (PETA). |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
The 16th Annual Meeting of the IEEE Lasers and Electro-Optics Society, 2003. LEOS 2003. |
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1510 |
Permanent link to this record |
|
|
|
Author |
Reiger, E.; Pan, D.; Slysz, W.; Jukna, A.; Sobolewski, R.; Dorenbos, S.; Zwiller, V.; Korneev, A.; Chulkova, G.; Milostnaya, I.; Minaeva, O.; Gol'tsman, G.; Kitaygorsky, J. |
Title |
Spectroscopy with nanostructured superconducting single photon detectors |
Type |
Journal Article |
Year |
2007 |
Publication |
IEEE J. Select. Topics Quantum Electron. |
Abbreviated Journal |
IEEE J. Select. Topics Quantum Electron. |
Volume |
13 |
Issue |
4 |
Pages |
934-943 |
Keywords |
SSPD, SNSPD |
Abstract |
Superconducting single-photon detectors (SSPDs) are nanostructured devices made from ultrathin superconducting films. They are typically operated at liquid helium temperature and exhibit high detection efficiency, in combination with very low dark counts, fast response time, and extremely low timing jitter, within a broad wavelength range from ultraviolet to mid-infrared (up to 6 mu m). SSPDs are very attractive for applications such as fiber-based telecommunication, where single-photon sensitivity and high photon-counting rates are required. We review the current state-of-the-art in the SSPD research and development, and compare the SSPD performance to the best semiconducting avalanche photodiodes and other superconducting photon detectors. Furthermore, we demonstrate that SSPDs can also be successfully implemented in photon-energy-resolving experiments. Our approach is based on the fact that the size of the hotspot, a nonsuperconducting region generated upon photon absorption, is linearly dependent on the photon energy. We introduce a statistical method, where, by measuring the SSPD system detection efficiency at different bias currents, we are able to resolve the wavelength of the incident photons with a resolution of 50 nm. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1077-260X |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1424 |
Permanent link to this record |
|
|
|
Author |
Korneev, Alexander; Vachtomin, Yury; Minaeva, Olga; Divochiy, Alexander; Smirnov, Konstantin; Okunev, Oleg; Gol'tsman, Gregory; Zinoni, C.; Chauvin, Nicolas; Balet, Laurent; Marsili, Francesco; Bitauld, David; Alloing, Blandine; Li, Lianhe; Fiore, Andrea; Lunghi, L.; Gerardino, Annamaria; Halder, Matthäus; Jorel, Corentin; Zbinden, Hugo |
Title |
Single-photon detection system for quantum optics applications |
Type |
Journal Article |
Year |
2007 |
Publication |
IEEE J. Select. Topics Quantum Electron. |
Abbreviated Journal |
IEEE J. Select. Topics Quantum Electron. |
Volume |
13 |
Issue |
4 |
Pages |
944-951 |
Keywords |
SSPD, SNSPD |
Abstract |
We describe the design and characterization of a fiber-coupled double-channel single-photon detection system based on superconducting single-photon detectors (SSPD), and its application for quantum optics experiments on semiconductor nanostructures. When operated at 2-K temperature, the system shows 10% quantum efficiency at 1.3-¿m wavelength with dark count rate below 10 counts per second and timing resolution <100 ps. The short recovery time and absence of afterpulsing leads to counting frequencies as high as 40 MHz. Moreover, the low dark count rate allows operation in continuous mode (without gating). These characteristics are very attractive-as compared to InGaAs avalanche photodiodes-for quantum optics experiments at telecommunication wavelengths. We demonstrate the use of the system in time-correlated fluorescence spectroscopy of quantum wells and in the measurement of the intensity correlation function of light emitted by semiconductor quantum dots at 1300 nm. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1077-260X |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
430 |
Permanent link to this record |
|
|
|
Author |
Korneev, A.; Kovalyuk, V.; Ferrari, S.; Kahl, O.; Pernice, W.; An, P.; Golikov, A.; Zubkova, E.; Goltsman, G. |
Title |
Superconducting Single-Photon Detectors for Integrated Nanophotonics Circuits |
Type |
Conference Article |
Year |
2017 |
Publication |
16th ISEC |
Abbreviated Journal |
16th ISEC |
Volume |
|
Issue |
|
Pages |
1-3 |
Keywords |
SSPD, SNSPD |
Abstract |
We present an overview of our recent achievements in integration of superconducting nanowire single-photon detectors SNSPD with dielectric optical waveguides. We are able to produce complex nanophotonics integrated circuits containing optical elements and photon detector on single chip thus producing a compact integrated platform for quantum optics applications. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
8314200 |
Serial |
1200 |
Permanent link to this record |
|
|
|
Author |
Goltsman, G. |
Title |
Superconducting thin film as infrared heterodyne and direct detectors |
Type |
Conference Article |
Year |
2017 |
Publication |
16th ISEC |
Abbreviated Journal |
16th ISEC |
Volume |
|
Issue |
|
Pages |
1-3 |
Keywords |
optical waveguide SSPD, SNSPD |
Abstract |
We present our recent achievements in the development of superconducting nanowire single-photon detectors (SNSPDs) integrated with optical waveguides on a chip. We demonstrate both single-photon counting with up to 90% on-chip-quantum-efficiency (OCDE), and the heterodyne mixing with a close to the quantum limit sensitivity at the telecommunication wavelength using single device. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
8314188 |
Serial |
1323 |
Permanent link to this record |
|
|
|
Author |
Tretyakov, I.; Svyatodukh, S.; Chumakova, A.; Perepelitsa, A.; Kaurova, N.; Shurakov, A.; Zilberley, T.; Ryabchun, S.; Smirnov, M.; Ovchinnikov, O.; Goltsman, G. |
Title |
Room temperature silicon detector for IR range coated with Ag2S quantum dots |
Type |
Conference Article |
Year |
2019 |
Publication |
IRMMW-THz |
Abbreviated Journal |
|
Volume |
|
Issue |
|
Pages |
|
Keywords |
Ag2S quantum dots |
Abstract |
A silicon has been the chief technological semiconducting material of modern microelectronics and has had a strong influence on all aspects of society. Applications of Si-based optoelectronic devices are limited to the visible and near infrared ranges. The expansion of the Si absorption to shorter wavelengths of the infrared range is of considerable interest to optoelectronic applications. By creating impurity states in Si it is possible to cause sub-band gap photon absorption. Here, we present an elegant and effective technology of extending the photoresponse of towards the IR range. Our approach is based on the use of Ag 2 S quantum dots (QDs) planted on the surface of Si. The specific sensitivity of the Ag 2 S/Si heterostructure is 10 11 cm√HzW -1 at 1.55μm. Our findings open a path towards the future study and development of Si detectors for technological applications. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2162-2035 |
ISBN |
978-1-5386-8285-2 |
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
8874267 |
Serial |
1286 |
Permanent link to this record |
|
|
|
Author |
Pentin, I. V.; Smirnov, A. V.; Ryabchun, S. A.; Gol’tsman, G. N.; Vaks, V. L.; Pripolzin, S. I.; Paveliev, D. G. |
Title |
Heterodyne source of THz range based on semiconductor superlattice multiplier |
Type |
Conference Article |
Year |
2011 |
Publication |
IRMMW-THz |
Abbreviated Journal |
IRMMW-THz |
Volume |
|
Issue |
|
Pages |
1-2 |
Keywords |
NbN HEB mixer, superlattice |
Abstract |
We present the results of our studies of the possibility of developing a heterodyne receiver incorporating a hot-electron bolometer mixer as the detector and a semiconductor superlattice multiplier driven by a reference synthesizer as the local oscillator. We observe that such a local oscillator offers enough power in the terahertz range to pump the HEB into the operating state. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
6105209 |
Serial |
1384 |
Permanent link to this record |
|
|
|
Author |
Cao, Aiqin; Jiang, L.; Chen, S.H.; Antipov, S.V.; Shi, S.C. |
Title |
IF gain bandwidth of a quasi-optical NbN superconducting HEB mixer |
Type |
Conference Article |
Year |
2007 |
Publication |
Proc. International conference on microwave and millimeter wave technology |
Abbreviated Journal |
Proc. ICMMT |
Volume |
|
Issue |
|
Pages |
1-3 |
Keywords |
HEB, mixer, gain bandwidth |
Abstract |
In this paper, the intermediate frequency (IF) gain bandwidth of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer is investigated at 500 GHz with an IF system incorporating with a frequency down-converting scheme which is able to sweep the IF signal in a frequency range of 0.3-4 GHz. The IF gain bandwidth of the device is measured to be 1.5 GHz when it is biased at a voltage of the minimum noise temperature, and becomes larger when the bias voltage increases. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Builin |
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
RPLAB @ lobanovyury @ |
Serial |
575 |
Permanent link to this record |
|
|
|
Author |
Palma, F.; Teppe, F.; Fatimy, A. E.; Green, R.; Xu, J.; Vachontin, Y.; Tredicucci, A.; Goltsman, G.; Knap, W. |
Title |
THz communication system based on a THz quantum cascade laser and a hot electron bolometer |
Type |
Conference Article |
Year |
2010 |
Publication |
35th Int. Conf. Infrared, Millimeter, and Terahertz Waves |
Abbreviated Journal |
35th Int. Conf. Infrared, Millimeter, and Terahertz Waves |
Volume |
|
Issue |
|
Pages |
11623798 (1 to 2) |
Keywords |
QCL, HEB detector |
Abstract |
We present the experimental study of the direct emission – detection system based on the THz Quantum Cascade Laser as a source and Hot Electron Bolometer (HEB) detector – in view of its application as an optical communication system. We show that the system can efficiently transmit the QCL Terahertz pulses. We estimate the maximal modulation speed of the system to be about several GHz and show that it is limited only by the QCL pulse power supply, detector amplifier and connection line/wires parameters. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
|
Editor |
|
Language |
|
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
|
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
|
Approved |
no |
Call Number |
|
Serial |
1391 |
Permanent link to this record |