Home | << 1 2 3 4 5 6 7 8 9 10 >> [11–16] |
Records | |||||
---|---|---|---|---|---|
Author | Hoevers, H. F. C.; Bento, A. C.; Bruijn, M. P.; Gottardi, L.; Korevaar, M. A. N.; Mels, W. A.; de Korte, P. A. J. | ||||
Title | Thermal fluctuation noise in a voltage biased superconducting transition edge thermometer | Type | Journal Article | ||
Year | 2000 | Publication | Applied Physics Letters | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 77 | Issue | 26 | Pages | 4421-4424 |
Keywords | TES; bolometer; thermal fluctuation noise; TFN | ||||
Abstract | The current noise at the output of a microcalorimeter with a voltage biased superconducting transition edge thermometer is studied in detail. In addition to the two well-known noise sources: thermal fluctuation noise from the heat link to the bath and Johnson noise from the resistive thermometer, a third noise source strongly correlated with the steepness of the thermometer is required to fit the measured noise spectra. Thermal fluctuation noise, originating in the thermometer itself, fully explains the additional noise. A simple model provides quantitative agreement between the observed and calculated noise spectra for all bias points in the superconducting transition. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | RPLAB @ gujma @ | Serial | 759 | ||
Permanent link to this record | |||||
Author | Burke, P. J.; Schoelkopf, R. J.; Prober, D. E.; Skalare, A.; Karasik, B. S.; Gaidis, M. C.; McGrath, W. R.; Bumble, B.; Leduc, H. G. | ||||
Title | Spectrum of thermal fluctuation noise in diffusion and phonon cooled hot-electron mixers | Type | Journal Article | ||
Year | 1998 | Publication | Applied Physics Letters | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 72 | Issue | 12 | Pages | 1516-1518 |
Keywords | HEB mixer; thermal fluctuation noise; TFN | ||||
Abstract | A systematic study of the intermediate frequency noise bandwidth of Nb thin-film superconducting hot-electron bolometers is presented. We have measured the spectrum of the output noise as well as the conversion efficiency over a very broad intermediate frequency range (from 0.1 to 7.5 GHz) for devices varying in length from 0.08 μm to 3 μm. Local oscillator and rf signals from 8 to 40 GHz were used. For a device of a given length, the spectrum of the output noise and the conversion efficiency behave similarly for intermediate frequencies less than the gain bandwidth, in accordance with a simple thermal model for both the mixing and thermal fluctuation noise. For higher intermediate frequencies the conversion efficiency decreases; in contrast, the noise decreases but has a second contribution which dominates at higher frequency. The noise bandwidth is larger than the gain bandwidth, and the mixer noise is low, between 120 and 530 K (double side band). | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | RPLAB @ gujma @ | Serial | 760 | ||
Permanent link to this record | |||||
Author | Sprengers, J. P.; Gaggero, A.; Sahin, D.; Jahanmirinejad, S.; Frucci, G.; Mattioli, F.; Leoni, R.; Beetz, J.; Lermer, M.; Kamp, M.; Höfling, S.; Sanjines, R.; Fiore A. | ||||
Title | Waveguide superconducting single-photon detectors for integrated quantum photonic circuits | Type | Journal Article | ||
Year | 2011 | Publication | Applied Physics Letters | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 99 | Issue | 18 | Pages | 181110(1-3) |
Keywords | optical waveguides, waveguide SSPD | ||||
Abstract | The monolithic integration of single-photon sources, passive optical circuits, and single-photon detectors enables complex and scalable quantum photonic integrated circuits, for application in linear-optics quantum computing and quantum communications. Here, we demonstrate a key component of such a circuit, a waveguide single-photon detector. Our detectors, based on superconducting nanowires on GaAs ridge waveguides, provide high efficiency (~0%) at telecom wavelengths, high timing accuracy (~0 ps), and response time in the ns range and are fully compatible with the integration of single-photon sources, passive networks, and modulators. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 847 | |||
Permanent link to this record | |||||
Author | Il'in, K. S.; Lindgren, M.; Currie, M. A.; Semenov, D.; Gol'tsman, G. N.; Sobolewski, Roman; Cherednichenko, S. I.; Gershenzon, E. M. | ||||
Title | Picosecond hot-electron energy relaxation in NbN superconducting photodetectors | Type | Journal Article | ||
Year | 2000 | Publication | Appl. Phys. Lett. | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 76 | Issue | 19 | Pages | 2752-2754 |
Keywords | NbN HEB detectors, two-temperature model, IF bandwidth | ||||
Abstract | We report time-resolved characterization of superconducting NbN hot-electron photodetectors using an electro-optic sampling method. Our samples were patterned into micron-size microbridges from 3.5-nm-thick NbN films deposited on sapphire substrates. The devices were illuminated with 100 fs optical pulses, and the photoresponse was measured in the ambient temperature range between 2.15 and 10.6 K (superconducting temperature transition TC). The experimental data agreed very well with the nonequilibrium hot-electron, two-temperature model. The quasiparticle thermalization time was ambient temperature independent and was measured to be 6.5 ps. The inelastic electron–phonon scattering time Ï„e–ph tended to decrease with the temperature increase, although its change remained within the experimental error, while the phonon escape time Ï„es decreased almost by a factor of two when the sample was put in direct contact with superfluid helium. Specifically, Ï„e–ph and Ï„es, fitted by the two-temperature model, were equal to 11.6 and 21 ps at 2.15 K, and 10(±2) and 38 ps at 10.5 K, respectively. The obtained value of Ï„e–ph shows that the maximum intermediate frequency bandwidth of NbN hot-electron phonon-cooled mixers operating at TC can reach 16(+4/–3) GHz if one eliminates the bolometric phonon-heating effect. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 856 | |||
Permanent link to this record | |||||
Author | Inderbitzin, K.; Engel, A.; Schilling, A.; Il'in, K.; Siegel, M. | ||||
Title | An ultra-fast superconducting Nb nanowire single-photon detector for soft x-rays | Type | Journal Article | ||
Year | 2012 | Publication | Abbreviated Journal | Appl. Phys. Lett. | |
Volume | 101 | Issue | Pages | ||
Keywords | SSPD, SNSPD, x-ray, Nb | ||||
Abstract | Although superconducting nanowire single-photon detectors (SNSPDs) are well studied regarding the detection of infrared/optical photons and keV-molecules, no studies on continuous x-ray photon counting by thick-film detectors have been reported so far. We fabricated a 100 nm thick niobium x-ray SNSPD (an X-SNSPD) and studied its detection capability of photons with keV-energies in continuous mode. The detector is capable to detect photons even at reduced bias currents of 0.4%, which is in sharp contrast to optical thin-film SNSPDs. No dark counts were recorded in extended measurement periods. Strikingly, the signal amplitude distribution depends significantly on the photon energy spectrum.VC |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | RPLAB @ seleznev @ | Serial | 878 | ||
Permanent link to this record |