Gerecht, E., Musante, C. F., Zhuang, Y., Ji, M., Yngvesson, K. S., Goyette, T., et al. (2000). NbN hot electron bolometric mixer with intrinsic receiver noise temperature of less than five times the quantum noise limit. In Proc. IMS (Vol. 2, pp. 1007–1010).
Abstract: In recent years, improvements in device development and quasi-optical coupling techniques utilizing planar antennas have led to a significant achievement in low noise receivers for the edges of the submillimeter frequency regime. Hot electron bolometric (HEB) receivers made of thin superconducting films such as NbN have produced a viable option for instruments designed to measure the molecular spectra for astronomical applications as well as in remote sensing of the atmosphere in the THz regime. This paper describes an NbN HEB mixer with intrinsic DSB receiver noise temperature of at most five times the quantum noise limit at frequencies as high as 2.24 THz
|
Wright, E. L., & Reese, E. D. (2000). Detection of the cosmic infrared background at 2.2 and 3.5 microns using DIRBE observations. Astrophys. J., 545(1), 43–55.
|
Saslaw, W. C. (2000). The distribution of the galaxies. Gravitational clustering in cosmology.
|
Kawamura, J., Blundell, R., Tong, C. - Y. E., Papa, D. C., Hunter, T. R., Paine, S. N., et al. (2000). Superconductive hot-electron-bolometer mixer receiver for 800-GHz operation. IEEE Trans. Microw. Theory Techn., 48(4), 683–689.
Abstract: In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-μm atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is TRX=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is PLO≈1 μW. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.
|
Nagatsuma, T., Hirata, A., Royter, Y., Shinagawa, M., Furuta, T., Ishibashi, T., et al. (2000). A 120-GHz integrated photonic transmitter. In Proc. International topical meeting on microwave photonics (MWP 2000) (pp. 225–228).
Abstract: A photonics-based 120-GHz transmitter has been developed. A photodiode, a planar antenna and a silicon lens were integrated to form a compact millimeter-wave (MMW) emitter. The MMW signal emitted from the transmitter has been detected with a waveguide-mounted Schottky diode. The received power exceeded 100 μW, which is the highest value ever reported for photonic MMW transmitter at frequencies of >100 GHz
|