Koshelets, V. P., Ermakov, A. B., Filippenko, L. V., Khudchenko, A. V., Kiselev, O. S., Sobolev, A. S., et al. (2007). Superconducting integrated submillimeter receiver for TELIS. IEEE Trans. Appl. Supercond., 17(2), 336–342.
|
Torgashin, M. Y., Koshelets, V. P., Dmitriev, P. N., Ermakov, A. B., Filippenko, L. V., & Yagoubov, P. A. (2007). Superconducting Integrated Receiver Based on Nb-AlN-NbN-Nb Circuits. IEEE Trans. Appl. Supercond., 17(2), 379–382.
|
Baselmans, J. J. A., Hajenius, M., Gao, J. R., Baryshev, A., Kooi, J., Klapwijk, T. M., et al. (2005). NbN hot electron bolometer mixers: sensitivity, LO power, direct detection and stability. IEEE Trans. Appl. Supercond., 15(2), 484–489.
Abstract: We demonstrate that the performance of NbN lattice cooled hot electron bolometer mixers depends strongly on the interface quality between the bolometer and the contact structure. Both the receiver noise temperature and the gain bandwidth can be improved by a factor of 2 by cleaning the interface and adding an additional superconducting interlayer to the contact pad. Using this we obtain a double sideband receiver noise temperature of 950 K at 2.5 THz and 4.3 K, using a 0.4/spl times/4 /spl mu/m HEB mixer with a spiral antenna. At the same bias point, we obtain an IF gain bandwidth of 6 GHz. To comply with current demands on THz mixers for use in space based receivers we reduce the device size to 0.15/spl times/1 /spl mu/m and use a twin slot antenna. We report measurements of the noise temperature, LO power requirement, stability and the direct detection effect, using a mixer with a 1.6 THz twin slot antenna and a 1.462 THz solid state LO source with calibrated output power.
|
Schwaab, G. W., Sirmain, G., Schubert, J., Hubers, H. - W., Gol'tsman, G., Cherednichenko, S., et al. (1999). Investigation of NbN phonon-cooled HEB mixers at 2.5 THz. IEEE Trans. Appl. Supercond., 9(2), 4233–4236.
Abstract: The development of superconducting hot electron bolometric (HEB) mixers has been a big step forward in the direction of quantum noise limited mixer performance at THz frequencies. Such mixers are crucial for the upcoming generation of airborne and spaceborne THz heterodyne receivers. In this paper we report on new results on a phonon-cooled NbN HEB mixer using e-beam lithography. The superconducting film is 3 nm thick. The mixer is 0.2 μm long and 1.5 μm wide and it is integrated in a spiral antenna on a Si substrate. The device is quasi-optically coupled through a Si lens and a dielectric beam combiner to the radiation of an optically pumped FIR ring gas laser cavity. The performance of the mixer at different THz frequencies from 0.69 to 2.55 THz with an emphasis on 2.52 THz is demonstrated. At 2.52 THz minimum DSB noise temperatures of 4200 K have been achieved at an IF of 1.5 GHz and a bandwidth of 40 MHz with the mixer mounted in a cryostat and a 0.8 m long signal path in air.
|
Gao, J. R., Hajenius, M., Yang, Z. Q., Baselmans, J. J. A., Khosropanah, P., Barends, R., et al. (2007). Terahertz superconducting hot electron bolometer heterodyne receivers. IEEE Trans. Appl. Supercond., 17(2), 252–258.
Abstract: We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.
|
Ryabchun, S., Tong, C. - Y. E., Blundell, R., & Gol'tsman, G. (2009). Stabilization scheme for hot-electron bolometer receivers using microwave radiation. IEEE Trans. Appl. Supercond., 19(1), 14–19.
Abstract: We present the results of a stabilization scheme for terahertz receivers based on NbN hot-electron bolometer (HEB) mixers that uses microwave radiation with a frequency much lower than the gap frequency of NbN to compensate for mixer current fluctuations. A feedback control loop, which actively controls the power level of the injected microwave radiation, has successfully been implemented to stabilize the operating point of the HEB mixer. This allows us to increase the receiver Allan time to 10 s and also improve the temperature resolution of the receiver by about 30% in the total power mode of operation.
|
Yang, J. K. W., Kerman, A. J., Dauler, E. A., Anant, V., Rosfjord, K. M., & Berggren, K. K. (2007). Modeling the electrical and thermal response of superconducting nanowire single-photon detectors. IEEE Trans. Appl. Supercond., 17(2), 581–585.
Abstract: We modeled the response of superconducting nanowire single-photon detectors during a photodetection event, taking into consideration only the thermal and electrical properties of a superconducting NbN nanowire on a sapphire substrate. Our calculations suggest that heating which occurs after the formation of a photo-induced resistive barrier is responsible for the generation of a measurable voltage pulse. We compared this numerical result with experimental data of a voltage pulse from a slow device, i.e. large kinetic inductance, and obtained a good fit. Using this electro-thermal model, we estimated the temperature rise and the resistance buildup in the nanowire, and the return current at which the nanowire becomes superconducting again. We also show that the reset time of these photodetectors can be decreased by the addition of a series resistance and provide supporting experimental data. Finally we present preliminary results on a detector latching behavior that can also be explained using the electro-thermal model.
|
Ryabchun, S., Tong, C. - Y. E., Paine, S., Lobanov, Y., Blundell, R., & Goltsman, G. (2009). Temperature resolution of an HEB receiver at 810 GHz. IEEE Trans. Appl. Supercond., 19(3), 293–296.
Abstract: We present the results of direct measurements of the temperature resolution of an HEB receiver operating at 810 GHz, in both continuum and spectroscopic modes. In the continuum mode, the input of the receiver was switched between black bodies with different physical temperatures. With a system noise temperature of around 1100 K, the receiver was able to resolve loads which differed in temperature by about 1 K over an integration time of 5 seconds. This resolution is significantly worse than the value of 0.07 K given by the radiometer equation. In the spectroscopic mode, a gas cell filled with carbonyl sulphide (OCS) gas was used and the emission line at 813.3537060 GHz was measured using the receiver in conjunction with a digital spectrometer. From the observed spectra, we determined that the measurement uncertainty of the equivalent emission temperature was 2.8 K for an integration time of 0.25 seconds and a spectral resolution of 12 MHz, compared to a 1.4 K temperature resolution given by the radiometer equation. This relative improvement is due to the fact that at short integration times the contribution from 1/f noise and drift are less dominant. In both modes, the temperature resolution was improved by about 40% with the use of a feedback loop which adjusted the level of an injected microwave radiation to maintain a constant operating current of the HEB mixer. This stabilization scheme has proved to be very effective to keep the temperature resolution of the HEB receiver to close to the theoretical value given by the radiometer equation.
|
Korneeva, Y., Florya, I., Semenov, A., Korneev, A., & Goltsman, G. (2011). New generation of nanowire NbN superconducting single-photon detector for mid-infrared. IEEE Trans. Appl. Supercond., 21(3), 323–326.
Abstract: We present a break-through approach to mid-infrared single-photon detection based on nanowire NbN superconducting single-photon detectors (SSPD). Although SSPD became a mature technology for telecom wavelengths (1.3-1.55 μm) its further expansion to mid-infrared wavelength was hampered by low sensitivity above 2 μm. We managed to overcome this limit by reducing the nanowire width to 50 nm, while retaining high superconducting properties and connecting the wires in parallel to produce a voltage response of sufficient magnitude. The new device exhibits 10 times better quantum efficiency at 3.5 μm wavelength than the “standard” SSPD.
|
Xiaolong Hu, Holzwarth, C. W., Masciarelli, D., Dauler, E. A., & Berggren, K. K. (2009). Efficiently coupling light to superconducting nanowire single-photon detectors. IEEE Trans. Appl. Supercond., 19(3), 336–340.
Abstract: We designed superconducting nanowire single-photon detectors (SNSPDs) integrated with silver optical antennae for free-space coupling and a dielectric waveguide for fiber coupling. According to our finite-element simulation, (1) for the free-space coupling, the absorptance of the NbN nanowire for TM-polarized photons at the wavelength of 1550 nm can be as high as 96% by adding silver optical antennae; (2) for the fiber coupling, the absorptance of the NbN nanowire for TE-like-polarized photons can reach 76% including coupling efficiency at the wavelength of 1550 nm by adding a silicon nitride waveguide and an inverse-taper coupler.
|
Yamashita, T., Miki, S., Qiu, W., Fujiwara, M., Sasaki, M., & Wang, Z. (2010). Temperature dependent performances of superconducting nanowire single-photon detectors in an ultralow-temperature region. IEEE Trans. Appl. Supercond., 21(3), 336–339.
Abstract: We report on the performance of a fiber-coupled superconducting nanowire single-photon detector (SNSPD) from 4 K down to the ultralow temperature of 16 mK for a 1550 nm wave length. The system detection efficiency (DE) increased with de creasing the temperature and reached the considerably high value of 15% with a dark count rate less than 100 cps below 1.5 K, even without an optical cavity structure. We also observed saturation of the system DE in its bias current dependency at 16 mK, which indicates that the device DE of our SNSPD nearly reached intrinsic DE despite the device having a large active area of 20 μm × 20 μm. The dark count was finite even at 16 mK and the black body radiation becomes its dominant origin in the low temperatures for fiber-coupled devices.
|
Yang, J. K. W., Kerman, A. J., Dauler, E. A., Cord, B., Anant, V., Molnar, R. J., et al. (2009). Suppressed critical current in superconducting nanowire single-photon detectors with high fill-factors. IEEE Trans. Appl. Supercond., 19(3), 318–322.
Abstract: In this work we present a new fabrication process that enabled the fabrication of superconducting nanowire single photon detectors SNSPD with fill-factors as high as 88% with gaps between nanowires as small as 12 nm. This fabrication process combined high-resolution electron-beam lithography with photolithography. Although this work was motivated by the potential of increased detection efficiency with higher fill-factor devices, test results showed an unexpected systematic suppression in device critical currents with increasing fill-factor.
|
Tretyakov, I., Ryabchun, S., Finkel, M., Maslennikov, S., Maslennikova, A., Kaurova, N., et al. (2011). Ultrawide noise bandwidth of NbN hot-electron bolometer mixers with in situ gold contacts. IEEE Trans. Appl. Supercond., 21(3), 620–623.
Abstract: We report a noise bandwidth of 7 GHz in the new generation of NbN hot-electron bolometer (HEB) mixers that are being developed for the space observatory Millimetron. The HEB receiver driven by a 2.5-THz local oscillator offered a noise temperature of 600 K in a 50-MHz final detection bandwidth. As the filter center frequency was swept this value remained nearly constant up to the cutoff frequency of the cryogenic amplifier at 7 GHz. We believe that such a low value of the noise temperature is due to reduced radio frequency (RF) loss at the interface between the superconducting film and the gold contacts. We have also performed gain bandwidth measurements at the superconducting transition on HEB mixers with various lengths and found them to be in excellent agreement with the results of the analytical and numerical models developed for the HEB mixer with both diffusion and phonon cooling of hot electrons.
|
Lobanov, Y., Tong, E., Blundell, R., Hedden, A., Voronov, B., & Gol'tsman, G. (2011). Large-signal frequency response of an HEB mixer: from 300 MHz to terahertz. IEEE Trans. Appl. Supercond., 21(3), 628–631.
Abstract: We present a study of the large signal frequency response of an HEB mixer over a wide frequency range. In our experiments, we have subjected the HEB mixer to incident electromagnetic radiation from 0.3 GHz to 1 THz. The mixer element is an NbN film deposited on crystalline quartz. The mixer chip is mounted in a waveguide cavity, coupled to free space with a diagonal horn. At microwave frequencies, electromagnetic radiation is applied through the coaxial bias port of the mixer block. At higher frequencies the input signal passes via the diagonal horn feed. At each frequency, the incident power is varied and a family of I-V curves is recorded. From the curves we identify 3 distinct regimes of operation of the mixer separated by the phonon relaxation frequency and the superconducting energy gap frequency observed at about 3 GHz and 660 GHz respectively. In this paper, we will present observed curves and discuss the results of our experiment.
|
Lobanov, Y. V., Tong, C. - Y. E., Hedden, A. S., Blundell, R., Voronov, B. M., & Gol'tsman, G. N. (2011). Direct measurement of the gain and noise bandwidths of HEB mixers. IEEE Trans. Appl. Supercond., 21(3), 645–648.
Abstract: The intermediate frequency (IF) bandwidth of a hot electron bolometer (HEB) mixer is an important parameter of the mixer, in that it helps to determine its suitability for a given application. With the availability of wideband low noise amplifiers, it is simple to measure the performance of an HEB mixer over a wide range of IF at a fixed LO frequency using the standard Y-factor method. This in-situ method allows us to measure both the gain and noise bandwidths simultaneously. We have also measured mixer output impedance with a vector network analyser. Intrinsic time constant has been extracted from the impedance data and compared to the mixer's bandwidths determined from receiver Y-factor measurement.
|