Home | << 1 2 3 4 5 6 7 8 9 10 >> [11–16] |
Records | |||||
---|---|---|---|---|---|
Author | Gao, J. R.; Hajenius, M.; Tichelaar, F. D.; Klapwijk, T. M.; Voronov, B.; Grishin, E.; Gol’tsman, G.; Zorman, C. A.; Mehregany, M. | ||||
Title | Monocrystalline NbN nanofilms on a 3C-SiC∕Si substrate | Type | Journal Article | ||
Year | 2007 | Publication | Appl. Phys. Lett. | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 91 | Issue | 6 | Pages | 062504 (1 to 3) |
Keywords | NbN films, nanofilms | ||||
Abstract | The authors have realized NbN (100) nanofilms on a 3C-SiC (100)/Si(100) substrate by dc reactive magnetron sputtering at 800°C. High-resolution transmission electron microscopy (HRTEM) is used to characterize the films, showing a monocrystalline structure and confirming epitaxial growth on the 3C-SiC layer. A film ranging in thickness from 3.4to4.1nm shows a superconducting transition temperature of 11.8K, which is the highest reported for NbN films of comparable thickness. The NbN nano-films on 3C-SiC offer a promising alternative to improve terahertz detectors. For comparison, NbN nanofilms grown directly on Si substrates are also studied by HRTEM. The authors acknowledge S. V. Svetchnikov at National Centre for HRTEM at Delft, who prepared the specimens for HRTEM inspections. This work was supported by the EU through RadioNet and INTAS. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1425 | |||
Permanent link to this record | |||||
Author | Zinoni, C.; Alloing, B.; Li, L. H.; Marsili, F.; Fiore, A.; Lunghi, L.; Gerardino, A.; Vakhtomin, Y. B.; Smirnov, K. V.; Gol’tsman, G. N. | ||||
Title | Single-photonics at telecom wavelengths using nanowire superconducting single photon detectors | Type | Conference Article | ||
Year | 2007 | Publication | CLEO/QELS | Abbreviated Journal | CLEO/QELS |
Volume | Issue | Pages | QTuF6 (1 to 2) | ||
Keywords | SSPD, SNSPD | ||||
Abstract | Novel single-photon detectors based on NbN superconducting nanostructures promise orders-of- magnitude improvement over InGaAs APDs. We demonstrate this improved performance for the first time by measuring the g(2)(τ) on single photon states produced by a quantum dot at telecom wavelength. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Optical Society of America | Place of Publication | Editor | ||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference and Photonic Applications Systems Technologies | ||
Notes | Approved | no | |||
Call Number | Zinoni:07 | Serial | 1432 | ||
Permanent link to this record | |||||
Author | Kerman, A. J.; Dauler, E. A.; Yang, J. K. W.; Rosfjord, K. M.; Anant, V.; Berggren, K. K.; Gol’tsman, G. N.; Voronov, B. M. | ||||
Title | Constriction-limited detection efficiency of superconducting nanowire single-photon detectors | Type | Journal Article | ||
Year | 2007 | Publication | Appl. Phys. Lett. | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 90 | Issue | 10 | Pages | 101110 (1 to 3) |
Keywords | SSPD, SNSPD | ||||
Abstract | We investigate the source of the large variations in the observed detection efficiencies of superconducting nanowire single-photon detectors between many nominally identical devices. Through both electrical and optical measurements, we infer that these variations arise from “constrictions:” highly localized regions of the nanowires where the effective cross-sectional area for superconducting current is reduced. These constrictions limit the bias-current density to well below its critical value over the remainder of the wire, and thus prevent the detection efficiency from reaching the high values that occur in these devices when they are biased near the critical current density. This work is sponsored by the United States Air Force under Contract No. FA8721-05-C-0002. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1433 | |||
Permanent link to this record | |||||
Author | Słysz, W.; Wegrzecki, M.; Bar, J.; Grabiec, P.; Górska, M.; Zwiller, V.; Latta, C.; Böhi, P.; Pearlman, A.J.; Cross, A.S.; Pan, D.; Kitaygorsky, J.; Komissarov, I.; Verevkin, A.; Milostnaya, I.; Korneev, A.; Minayeva, O.; Chulkova, G.; Smirnov, K.; Voronov, B.; Gol’tsman, G.N.; Sobolewski, R. | ||||
Title | Fibre-coupled, single photon detector based on NbN superconducting nanostructures for quantum communications | Type | Journal Article | ||
Year | 2007 | Publication | J. Modern Opt. | Abbreviated Journal | J. Modern Opt. |
Volume | 54 | Issue | 2-3 | Pages | 315-326 |
Keywords | NbN SSPD, SNSPD | ||||
Abstract | We present a novel, two-channel, single photon receiver based on two fibre-coupled, NbN, superconducting, single photon detectors (SSPDs). The SSPDs are nanostructured superconducting meanders and are known for ultrafast and efficient detection of visible-to-infrared photons. Coupling between the NbN detector and optical fibre was achieved using a micromechanical photoresist ring placed directly over the SSPD, holding the fibre in place. With this arrangement, we obtained coupling efficiencies up to ∼30%. Our experimental results showed that the best receiver had a near-infrared system quantum efficiency of 0.33% at 4.2 K. The quantum efficiency increased exponentially with the photon energy increase, reaching a few percent level for visible-light photons. The photoresponse pulses of our devices were limited by the meander high kinetic inductance and had the rise and fall times of approximately 250 ps and 5 ns, respectively. The receiver's timing jitter was in the 37 to 58 ps range, approximately 2 to 3 times larger than in our older free-space-coupled SSPDs. We stipulate that this timing jitter is in part due to optical fibre properties. Besides quantum communications, the two-detector arrangement should also find applications in quantum correlation experiments. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0950-0340 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1434 | |||
Permanent link to this record | |||||
Author | Baselmans, J. J. A.; Baryshev, A.; Reker, S. F.; Hajenius, M.; Gao, J. R.; Klapwijk, T. M.; Voronov, B.; Gol’tsman, G. | ||||
Title | Influence of the direct response on the heterodyne sensitivity of hot electron bolometer mixers | Type | Journal Article | ||
Year | 2006 | Publication | J. Appl. Phys. | Abbreviated Journal | J. Appl. Phys. |
Volume | 100 | Issue | 8 | Pages | 084510 (1 to 7) |
Keywords | NbN HEB mixers | ||||
Abstract | We present a detailed experimental study of the direct detection effect in a small volume (0.15μm×1μm×3.5nm) quasioptical NbN phonon cooled hot electron bolometer mixer at 673GHz. We find that the small signal noise temperature, relevant for an astronomical observation, is 20% lower than the noise temperature obtained using 300 and 77K calibration loads. In a separate set of experiments we show that the direct detection effect is caused by a combination of bias current reduction when switching from the 77 to the 300K load in combination with the bias current dependence of the receiver gain. The bias current dependence of the receiver gain is shown to be mainly caused by the current dependence of the mixer gain. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0021-8979 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1442 | |||
Permanent link to this record | |||||
Author | Kooi, J. W.; Baselmans, J. J. A.; Baryshev, A.; Schieder, R.; Hajenius, M.; Gao, J.R.; Klapwijk, T. M.; Voronov, B.; Gol’tsman, G. | ||||
Title | Stability of heterodyne terahertz receivers | Type | Journal Article | ||
Year | 2006 | Publication | J. Appl. Phys. | Abbreviated Journal | J. Appl. Phys. |
Volume | 100 | Issue | 6 | Pages | 064904 (1 to 9) |
Keywords | NbN HEB mixers | ||||
Abstract | In this paper we discuss the stability of heterodyne terahertz receivers based on small volume NbN phonon cooled hot electron bolometers (HEBs). The stability of these receivers can be broken down in two parts: the intrinsic stability of the HEB mixer and the stability of the local oscillator (LO) signal injection scheme. Measurements show that the HEB mixer stability is limited by gain fluctuations with a 1∕f spectral distribution. In a 60MHz noise bandwidth this results in an Allan variance stability time of ∼0.3s. Measurement of the spectroscopic Allan variance between two intermediate frequency (IF) channels results in a much longer Allan variance stability time, i.e., 3s between a 2.5 and a 4.7GHz channel, and even longer for more closely spaced channels. This implies that the HEB mixer 1∕f noise is strongly correlated across the IF band and that the correlation gets stronger the closer the IF channels are spaced. In the second part of the paper we discuss atmospheric and mechanical system stability requirements on the LO-mixer cavity path length. We calculate the mixer output noise fluctuations as a result of small perturbations of the LO-mixer standing wave, and find very stringent mechanical and atmospheric tolerance requirements for receivers operating at terahertz frequencies. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0021-8979 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1444 | |||
Permanent link to this record | |||||
Author | Vachtomin, Y. B.; Antipov, S. V.; Maslennikov, S. N.; Smirnov, K. V.; Polyakov, S. L.; Zhang, W.; Svechnikov, S. I.; Kaurova, N. S.; Grishina, E. V.; Voronov, B. M.; Gol’tsman, G. N. | ||||
Title | Quasioptical hot electron bolometer mixers based on thin NBN films for terahertz region | Type | Conference Article | ||
Year | 2006 | Publication | Proc. 16th Int. Crimean Microwave and Telecommunication Technology | Abbreviated Journal | Proc. 16th Int. Crimean Microwave and Telecommunication Technology |
Volume | 2 | Issue | Pages | 688-689 | |
Keywords | NbN HEB mixers | ||||
Abstract | Presented in this paper are the performances of HEB mixers based on 2-3.5 nm thick NbN films integrated with log-periodic spiral antenna. Double side-band receiver noise temperature values are 1300 K and 3100 K at 2.5 THz and at 3.8 THz, respectively. Mixer gain bandwidth is 5.2 GHz. Local oscillator power is 1-3 muW for mixers with different active area | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Russian | Summary Language | Original Title | ||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1445 | |||
Permanent link to this record | |||||
Author | Smirnov, K.; Korneev, A.; Minaeva, O.; Divochij, A.; Rubtsova, I.; Antipov, A.; Ryabchun, S.; Okunev, O.; Milostnaya, I.; Chulkova, G.; Voronov, B.; Kaurova, N.; Seleznev, V.; Korotetskaya, Y.; Gol’tsman, G. | ||||
Title | Superconducting single-photon detector for near- and middle IR wavelength range | Type | Conference Article | ||
Year | 2006 | Publication | Proc. 16th Int. Crimean Microwave and Telecommunication Technology | Abbreviated Journal | Proc. 16th Int. Crimean Microwave and Telecommunication Technology |
Volume | 2 | Issue | Pages | 684-685 | |
Keywords | NbN SSPD, SNSPD | ||||
Abstract | Presented in this paper are the results of research of NbN-film superconducting single-photon detector. At 2 K temperature, quantum efficiency in the visible light (0.56 mum) reaches 30-40 %. With the wavelength increase quantum efficiency decreases and comes to 20% at 1.55 mum and 0.02% at 5.6 mum. Minimum dark counts rate is 2times10-4s-1. The jitter of detector is 35 ps. The detector was successfully implemented for integrated circuits non-invasive optical testing. It is also perspective for quantum cryptography systems | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Russian | Summary Language | Original Title | ||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1447 | |||
Permanent link to this record | |||||
Author | Słysz, W.; Węgrzecki, M.; Bar, J.; Grabiec, P.; Górska, M.; Zwiller, V.; Latta, C.; Bohi, P.; Milostnaya, I.; Minaeva, O.; Antipov, A.; Okunev, O.; Korneev, A.; Smirnov, K.; Voronov, B.; Kaurova, N.; Gol’tsman, G.; Pearlman, A.; Cross, A.; Komissarov, I.; Verevkin, A.; Sobolewski, R. | ||||
Title | Fiber-coupled single-photon detectors based on NbN superconducting nanostructures for practical quantum cryptography and photon-correlation studies | Type | Journal Article | ||
Year | 2006 | Publication | Appl. Phys. Lett. | Abbreviated Journal | Appl. Phys. Lett. |
Volume | 88 | Issue | 26 | Pages | 261113 (1 to 3) |
Keywords | SSPD, SNSPD | ||||
Abstract | We have fabricated and tested a two-channel single-photon detector system based on two fiber-coupled superconducting single-photon detectors (SSPDs). Our best device reached the system quantum efficiency of 0.3% in the 1540-nm telecommunication wavelength with a fiber-to-detector coupling factor of about 30%. The photoresponse consisted of 2.5-ns-wide voltage pulses with a rise time of 250ps and timing jitter below 40ps. The overall system response time, measured as a second-order, photon cross-correlation function, was below 400ps. Our SSPDs operate at 4.2K inside a liquid-helium Dewar, but their optical fiber inputs and electrical outputs are at room temperature. Our two-channel detector system should find applications in practical quantum cryptography and in antibunching-type quantum correlation measurements. The authors would like to thank Dr. Marc Currie for his assistance in early time-resolved photoresponse measurements and Professor Atac Imamoglu for his support. This work was supported by the Polish Ministry of Science under Project No. 3 T11B 052 26 (Warsaw), RFBR 03-02-17697 and INTAS 03-51-4145 grants (Moscow), CRDF Grant No. RE2-2531-MO-03 (Moscow), RE2-2529-MO-03 (Moscow and Rochester), and US AFOSR FA9550-04-1-0123 (Rochester). Additional funding was provided by the grants from the MIT Lincoln Laboratory and BBN Technologies Corp. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0003-6951 | ISBN | Medium | ||
Area | Expedition | Conference | |||
Notes | Approved | no | |||
Call Number | Serial | 1449 | |||
Permanent link to this record | |||||
Author | Dauler, E. A.; Kerman, A. J.; Robinson, B. S.; Yang, J. K. W.; Voronov, B. M.; Gol’tsman, G. N.; Berggren, K. K. | ||||
Title | Achieving high counting rates in superconducting nanowire single-photon detectors | Type | Conference Article | ||
Year | 2006 | Publication | CLEO/QELS | Abbreviated Journal | CLEO/QELS |
Volume | Issue | Pages | JTuD3 (1 to 2) | ||
Keywords | SSPD; SNSPD; Detectors; Photodetectors; Quantum optics; Quantum detectors; Photon counting; Photons; Pulse shaping; Quantum communications; Single photon detectors; Superconductors | ||||
Abstract | Kinetic inductance is determined to be the primary limitation to the counting rate of superconducting nanowire single-photon counters. Approaches for overcoming this limitation will be discussed. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Optical Society of America | Place of Publication | Editor | ||
Language | Summary Language | Original Title | |||
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | ISBN | Medium | |||
Area | Expedition | Conference | Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference and Photonic Applications Systems Technologies | ||
Notes | Approved | no | |||
Call Number | Serial | 1451 | |||
Permanent link to this record |