Siddiqi, I., & Prober, D. E. (2004). Nb–Au bilayer hot-electron bolometers for low-noise THz heterodyne detection. Appl. Phys. Lett., 84(8), 1404.
Abstract: The sensitivity of present Nb diffusion-cooled hot-electron bolometer (HEB) mixers is not quantum limited, and can be improved by reducing the superconducting transition temperature TC. Lowering TC reduces thermal fluctuations, resulting in a decrease of the mixer noise temperature TM. However, lower TC mixers have reduced dynamic range and saturate more easily due to background noise. We present 30 GHz microwave measurements on a bilayer HEB system, Nb–Au, in which TC can be tuned with Au layer thickness to obtain the maximum sensitivity for a given noise background. These measurements are intended as a guide for the optimization of THz mixers. Using a Nb–Au mixer with TC = 1.6 K, we obtain TM = 50 K with 2 nW of local oscillator (LO) power. Good mixer performance is observed over a wide range of LO power and bias voltage and such a device should not exhibit saturation in a THz receiver.
|
|
|
Zwiller, V., Aichele, T., Seifert, W., Persson, J., & Benson, O. (2003). Generating visible single photons on demand with single InP quantum dots. Appl. Phys. Lett., 82(10), 1509–1511.
|
|
|
Burke, P. J., Schoelkopf, R. J., Prober, D. E., Skalare, A., Karasik, B. S., Gaidis, M. C., et al. (1998). Spectrum of thermal fluctuation noise in diffusion and phonon cooled hot-electron mixers. Appl. Phys. Lett., 72(12), 1516–1518.
Abstract: A systematic study of the intermediate frequency noise bandwidth of Nb thin-film superconducting hot-electron bolometers is presented. We have measured the spectrum of the output noise as well as the conversion efficiency over a very broad intermediate frequency range (from 0.1 to 7.5 GHz) for devices varying in length from 0.08 μm to 3 μm. Local oscillator and rf signals from 8 to 40 GHz were used. For a device of a given length, the spectrum of the output noise and the conversion efficiency behave similarly for intermediate frequencies less than the gain bandwidth, in accordance with a simple thermal model for both the mixing and thermal fluctuation noise. For higher intermediate frequencies the conversion efficiency decreases; in contrast, the noise decreases but has a second contribution which dominates at higher frequency. The noise bandwidth is larger than the gain bandwidth, and the mixer noise is low, between 120 and 530 K (double side band).
|
|
|
Mason, W., & Waterman, J. R. (1999). Electrical and optical characteristics of two color mid wave HgCdTe infrared detectors. Appl. Phys. Lett., 74(11), 1633–1635.
|
|
|
Karasik, B. S., Il'in, K. S., Pechen, E. V., & Krasnosvobodtsev, S. I. (1996). Diffusion cooling mechanism in a hot-electron NbC microbolometer mixer. Appl. Phys. Lett., 68(16), 2285–2287.
|
|