Ejrnaes, M., Cristiano, R., Quaranta, O., Pagano, S., Gaggero, A., Mattioli, F., et al. (2007). A cascade switching superconducting single photon detector. Appl. Phys. Lett., 91(26), 262509 (1 to 3).
Abstract: We have realized superconducting single photon detectors with reduced inductance and increased signal pulse amplitude. The detectors are based on a parallel connection of ultrathin NbN nanowires with a common bias inductance. When properly biased, an absorbed photon induces a cascade switch of all the parallel wires generating a signal pulse amplitude of 2mV. The parallel wire configuration lowers the detector inductance and reduces the response time well below 1ns.
This work was performed in the framework of the EU project “SINPHONIA” NMP4-CT-2005-016433.
|
Zhang, W., Li, N., Jiang, L., Ren, Y., Yao, Q. - J., Lin, Z. - H., et al. (2008). Dependence of noise temperature of quasi-optical superconducting hot-electron bolometer mixers on bath temperature and optical-axis displacement. In C. Zhang, & X. - C. Zhang (Eds.), Proc. SPIE (Vol. 6840, 684007 (1 to 8)). Spie.
Abstract: It is known that the increase of bath temperature results in the decrease of critical current of superconducting hot-electron bolometer (HEB) mixers owing to the depression of superconductivity, thus leading to the degradation of the mixer’s sensitivity. Here we report our study on the effect of bath temperature on the heterodyne mixing performance of quasi-optical superconducting NbN HEB mixers incorporated with a two-arm log-spiral antenna. The correlation between the bath temperature, critical current, LO power requirement and noise temperature is investigated at 0.5 THz. Furthermore, the heterodyne mixing performance of quasi-optical superconducting NbN HEB mixers is examined while there is an optical-axis displacement between the center of the extended hemispherical silicon lens and the superconducting NbN HEB device, which is placed on the back of the lens. Detailed experimental results and analysis are presented.
|
Tong, C. - Y. E., Trifonov, A., Shurakov, A., Blundell, R., & Gol’tsman, G. (2015). A microwave-operated hot-electron-bolometric power detector for terahertz radiation. IEEE Trans. Appl. Supercond., 25(3), 2300604 (1 to 4).
Abstract: A new class of microwave-operated THz power detectors based on the NbN hot-electron-bolometer (HEB) mixer is proposed. The injected microwave signal ( 1 GHz) serves the dual purpose of pumping the HEB element and enabling the read-out of the internal state of the device. A cryogenic amplifier amplifies the reflected microwave signal from the device and a homodyne scheme recovers the effects of the incident THz radiation. Two modes of operation have been identified, depending on the level of incident radiation. For weak signals, we use a chopper to chop the incident radiation against a black body reference and a lock-in amplifier to perform synchronous detection of the homodyne readout. The voltage measured is proportional to the incident power, and we estimate an optical noise equivalent power of 5pW/ √Hz at 0.83 THz. At higher signal levels, the homodyne circuit recovers the stream of steady relaxation oscillation pulses from the HEB device. The frequency of these pulses is in the MHz frequency range and bears a linear relationship with the incident THz radiation over an input power range of 15 dB. A digital frequency counter is used to measure THz power. The applicable power range is between 1 nW and 1 μW.
|