|
Fu, K., Zannoni, R., Chan, C., Adams, S. H., Nicholson, J., Polizzi, E., et al. (2008). Terahertz detection in single wall carbon nanotubes. Appl. Phys. Lett., 92(3), 033105.
Abstract: It is reported that terahertz radiation from 0.69 to 2.54 THz has been sensitively detected in a device consisting of bundles of carbon nanotubes containing single wall metallic carbon nanotubes, quasioptically coupled through a lithographically fabricated antenna, and a silicon lens. The measured data are consistent with a bolometric detection process in the metallic tubes and the devices show promise for operation well above 4.2 K.
|
|
|
Rodriguez-Morales, F., Zannoni, R., Nicholson, J., Fischetti, M., Yngvesson, K. S., & Appenzeller, J. (2006). Direct and heterodyne detection of microwaves in a metallic single wall carbon nanotube. Appl. Phys. Lett., 89(8), 083502.
|
|
|
Santavicca, D. F., Reulet, B., Karasik, B. S., Pereverzev, S. V., Olaya, D., Gershenson, M. E., et al. (2010). Energy resolution of terahertz single-photon-sensitive bolometric detectors. Appl. Phys. Lett., 96(8), 083505-3.
Abstract: We report measurements of the energy resolution of ultrasensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single higher-frequency photon, where the absorbed energy of the pulse is equal to the photon energy. This technique allows precise calibration of the input coupling and avoids problems with unwanted background photons. Present devices have an intrinsic full-width at half-maximum energy resolution of approximately 23 THz, near the predicted value due to intrinsic thermal fluctuation noise.
|
|
|
Zhang, W., Khosropanah, P., Gao, J. R., Kollberg, E. L., Yngvesson, K. S., Bansal, T., et al. (2010). Quantum noise in a terahertz hot electron bolometer mixer. Appl. Phys. Lett., 96(11), 111113–(1–3).
Abstract: We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The beta-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.
|
|
|
Dorenbos, S. N., Reiger, E. M., Perinetti, U., Zwiller, V., Zijlstra, T., & Klapwijk, T. M. (2008). Low noise superconducting single photon detectors on silicon. Appl. Phys. Lett., 93(13), 131101.
|
|