|
Jiang, L., Miao, W., Zhang, W., Li, N., Lin, Z. H., Yao, Q. J., et al. (2006). Characterization of quasi-optical NbN phonon-cooled superconducting HEB mixers. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 55–58).
Abstract: In this paper, we thoroughly investigate the performance of quasi-optical NbN phonon-cooled superconducting hot-electron bolometer (HEB) mixers, cryogenically cooled by a close-cycled 4-K refrigerator at 500 GI-1z and 850 GHz. The uncorrected lowest receiver noise Abstract---In temperatures measured are 800 K at 500 CHz without anti-reflection coating, and 1000 K @ 850 GHz with a 50 11M thick Mylar anti-reflection coating. The dependence of receiver noise temperature on the critical current and bath temperature of HEB mixer is also investigated here. Lifetime of quasi-optical superconducting NbN HEB mixers of different volumes, room temperature resistances, and critical temperatures are thoroughly studied. Increased room temperature resistance with time over the initial resistance changes between 1 and 1.2, and the reduced critical current with time over the initial value fluctuates slightly around 0.7 for most HEB mixers even of different volumes, room temperature resistances, and critical temperatures. The critical current degrades sharply vvhile room temperature resistance varies over 1.25.
|
|
|
Verevkin, A. A., Ptitsina, N. G., Smirnov, K. V., Goltsman, G. N., Gershenson, E. M., & Yngvesson, K. S. (1997). Direct measurements of electron energy relaxation times at an AlGaAs/GaAs heterointerface in the optical phonon scattering range. In Proc. 4-th Int. Semicond. Device Research Symp. (pp. 55–58).
|
|
|
Yagoubov, P., Hübers, H. - W., Gol’tsman, G., Semenov, A., Gao, J., Hoogeveen, R., et al. (2001). Hot-electron bolometer mixers – technology for far-infrared heterodyne instruments in future atmospheric chemistry missions. In S. Buehler, & Berlin (Eds.), Proc. 3rd Int. Symp. Submillimeter Wave Earth Observation From Space (pp. 57–69). Logos-Verlag.
|
|
|
Gao, J. R., Hiajenius, M., Yang, Z. Q., Klapwijk, T. M., Miao, W., Shi, S. C., et al. (2006). Direct comparison of the sensitivity of a spiral and a twin-slot antenna coupled HEB mixer at 1.6 THz. In Proc. 17th Int. Symp. Space Terahertz Technol. (pp. 59–62).
Abstract: To make a direct comparison of the sensitivity between a spiral and a twin slot antenna coupled HEB mixer, we designed both types of mixers and fabricated them in a single processing run and on the same wafer. Both mixers have similar dimensions of NbN bridges (1.5-2 pm x0.2 pm). At 1.6 THz we obtained a nearly identical receiver noise temperature from both mixers (only 5% difference), which is in a good agreement with the simulation based on semi analytical models for both antennas. In addition, by using a bandpass filter to reduce the direct detection effect and lowering the bath temperature to 2.4 K, we measured the lowest receiver noise temperature of 700 K at 1.63 THz using the twin-slot antenna mixer.
|
|
|
Золотов, Ф. И., Дивочий, А. В., Вахтомин, Ю. Б., Пентин, И. В., Морозов, П. В., Селезнев, В. А., et al. (2018). Применение тонких сверхпроводниковых пленок нитрида ванадия для изготовления счетчиков одиночных ИК-фотонов. In Сборн. науч. труд. VII международн. конф. по фотонике и информац. опт. (pp. 60–61).
Abstract: Получены первые результаты по применению сверхпроводниковых пленок нитрида ванадия (VN) для детекторов одиночных фотонов ИК-диапазона. Изучение сверхпроводниковых однофотонных детекторов (SSPD), изготовленных на основе ультратонких (~5 нм) пленок VN, показало возможность создания устройств с близкой к насыщению зависимостью квантовой эффективности от тока смещения детекторов в телекоммуникационном диапазоне длин волн. Также нами были исследованы кинетическая индуктивность изготовленных структур с различной длиной сверхпроводниковой полоски и времена релаксации электронов в тонких сверхпроводниковых пленках VN.
|
|