Gershenzon, E. M., Gol'tsman, G. N., & Ptitsina, N. G. (1976). Investigation of free excitons in Ge and their condensation at submillimeter wavelengths. Sov. Phys. JETP, 43(1), 116–122.
Abstract: Results are presented of an investigation of free excitons in Ge in the submillimeter wavelength range for low as well as for high excitation levels when interaction between the excitons becomes important. The free-exciton energy spectrum is discussed. It is shown that the drop radii and their concentrations can be determined by measuring the temperature dependence of the free-exciton concentration. A section of the phase diagram is obtained in the 0.5-2.8 K temperature range for the free excitons+condensate system.
|
Gershenzon, E. M., Il'in, V. A., Litvak-Gorskaya, L. B., & Filonovich, S. R. (1979). Character of submillimeter photoconductivity in n-lnSb. Sov. Phys. JETP, 49(1), 121–128.
Abstract: A comprehensive investigation was made of the submillimeter photoconductivity of n -1nSb in the range of wavelengths L = 0.6-8 mm, magnetic fields H = 0-30 kOe, electric fields E = 0.01-0.5 V/cm, and temperatures T = 1.3-30 K. The kinetics of the photoconductivity processes as a function of T, E; and H is investigated. It is shown that impurity photoconductivity does exist for any degree of compensation of extremely purified n-InSb. Particular attention is paid to the hopping photoconductivity realized in strongly compensated n-1nSb (K > 0.8).
|
Gousev, Y. P., Olsson, H. K., Gol'tsman, G. N., Voronov, B. M., & Gershenzon, E. M. (1998). NbN hot-electron mixer at radiation frequencies between 0.9 THz and 1.2 THz. In Proc. 9th Int. Symp. Space Terahertz Technol. (pp. 121–129).
Abstract: We report on noise temperature measurements for a NbN phonon-cooled hot-electron mixer at radiation frequencies between 0.9 THz and 1.2 THz. Radiation was coupled to the mixer, placed in a vacuum chamber of He cryostat, by means of a planar spiral antenna and a Si immersion lens. A backward-wave oscillator, tunable throughout the spectral range, delivered an output power of few 1.1W that was enough for optimum operation of the mixer. At 4.2 K ambient temperature and 1.025 THz radiation frequency, we obtained a receiver noise temperature of 1550 K despite of using a relatively noisy room-temperature amplifier at the intermediate frequency port. The noise temperature was fairly constant throughout the entire operation range and for intermediate frequencies from 1 GHz to 2 GHz.
|
Aksaev, E. E., Gershenzon, E. M., Gol'tsman, G. N., Mirskij, G. I., & Semenov, A. D. (1991). Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution. Pribory i Tekhnika Eksperimenta, 34(2), 125–131.
Abstract: The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
|
Gershenzon, E. M., Orlova, S. L., Orlov, L. A., Ptitsina, N. G., & Rabinovich, R. I. (1976). Intervalley cyclotron-impurity resonance of electrons in n-Ge. JETP Lett., 24(3), 125–128.
|