|
Records |
Links |
|
Author |
Zubkova, E.; An, P.; Kovalyuk, V.; Korneev, A.; Goltsman, G. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Integrated Bragg waveguides as an efficient optical notch filter on silicon nitride platform |
Type |
Conference Article |
|
Year |
2017 |
Publication |
Proc. SPBOPEN |
Abbreviated Journal |
Proc. SPBOPEN |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
449-450 |
|
|
Keywords |
Bragg waveguides |
|
|
Abstract |
We modeled and fabricated integrated optical Bragg waveguides on a silicon nitride (Si3N4) platform. Transmission spectra of the integrated notch filter has been measured and attenuation at the desired wavelength of 1550 nm down to -43 dB was observed. |
|
|
Address |
St. Petersburg, Russia |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Duplicated as 1141 |
Approved |
no |
|
|
Call Number |
|
Serial |
1257 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol'tsman, G. N. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Effect of electromagnetic radiation on a superconductor in a magnetic field |
Type |
Conference Article |
|
Year |
1988 |
Publication |
Izv. Akad. Nauk SSSR, Seriya Fizicheskaya |
Abbreviated Journal |
Izv. Akad. Nauk SSSR, Seriya Fizicheskaya |
|
|
Volume |
52 |
Issue |
3 |
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
449-451 |
|
|
Keywords |
|
|
|
Abstract |
The effect of electromagnetic radiation on thin superconducting films of Nb with a large number of static defects is investigated experimentally for the case where the film is in the resistive state due to an applied magnetic field and transport current. The results obtained are found to be well described by a model of spatially homogeneous electron heating. It is noted that the results obtained here for Nb films are also valid for Al, NbN, and MoRe films. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
Russian |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0367-6765 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
4th Vsesoiuznyi Seminar po Opticheskomu Detektirovaniiu Magnitnykh Rezonansov v Tverdykh Telakh, Tallin, Estonian SSR, Apr. 1987 |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1702 |
|
Permanent link to this record |
|
|
|
|
Author |
Edward Tong, C.-Y.; Loudkov, Denis N.; Paine, Scott N.; Marrone, Dan P.; Blundell, Raymond |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Vector measurement of the beam pattern of a 1.5 THz superconducting HEB receiver |
Type |
Conference Article |
|
Year |
2005 |
Publication |
Proc. 16th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 16th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
453-456 |
|
|
Keywords |
NbTiN HEB mixers |
|
|
Abstract |
Near-field vector beam pattern of the 1.5 THz superconducting Hot Electron Bolometer (HEB) receiver currently in operation in Northern Chile has been performed in our laboratory. Using an open waveguide probe, we have mapped both the amplitude and phase of the beam emerging from our 1.5 THz HEB receiver package, across a number of planes along the line of propagation of the radio-beam. With an integration time of about 100 ms per point, a signal-to-noise ratio of about 25 dB was achieved for a beam waist of 3.5 mm. These measurements have proved to be invaluable in achieving good alignment between the cryostat housing the HEB mixer and the remainder of the receiver and telescope optics. The accuracy of our beam measurement is estimated to be ±0.2 mm in position and ±5 arc minutes in angular displacement. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1474 |
|
Permanent link to this record |
|
|
|
|
Author |
Baselmans, J.; Kooi, J.; Baryshev, A.; Yang, Z. Q.; Hajenius, M.; Gao, J. R.; Klapwijk, T. M.; Voronov, B.; Gol’tsman, G. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Full characterization of small volume NbN HEB mixers for space applications |
Type |
Conference Article |
|
Year |
2005 |
Publication |
Proc. 16th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 16th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
457-462 |
|
|
Keywords |
NbN HEB mixers |
|
|
Abstract |
NbN phonon cooled HEB’s are one of the most promising bolometer mixer technologies for (near) future (space) applications. Their performance is usually quantified by mea- suring the receiver noise temperature at a given IF frequency, usually around 1 – 2 GHz. However, for any real applications it is vital that one fully knows all the relevant properties of the mixer, including LO power, stability, direct detection, gain bandwidth and noise bandwidth, not only the noise temperature at low IF frequencies. To this aim we have measured all these parameters at the optimal operating point of one single, small volume quasioptical NbN HEB mixer. We find a minimum noise temperature of 900 K at 1.46 THz. We observe a direct detection effect indicated by a change in bias current when changing from a 300 K hot load to a 77 K cold load. Due to this effect we overestimate the noise temperature by about 22% using a 300 K hot load and a 77 K cold load. The LO power needed to reach the optimal operating point is 80 nW at the receiver lens front, 59 nW inside the NbN bridge. However, using the isothermal technique we find a power absorbed in the NbN bridge of 25 nW, a difference of about a factor 2. We obtain a gain bandwidth of 2.3 GHz and a noise bandwidth of 4 GHz. The system Allan time is about 1 sec. in a 50 MHz spectral bandwidth and a deviation from white noise integration (governed by the radiometer equation) occurs at 0.2 sec., which implies a maximum integration time of a few seconds in a 1 MHz bandwidth spectrometer. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Göteborg, Sweden |
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
363 |
|
Permanent link to this record |
|
|
|
|
Author |
Gershenzon, E. M.; Gol’tsman, G. N.; Sergeev, A.; Semenov, A. D. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Picosecond response of YBaCuO films to electromagnetic radiation |
Type |
Conference Article |
|
Year |
1990 |
Publication |
Proc. European Conf. High-Tc Thin Films and Single Crystals |
Abbreviated Journal |
Proc. European Conf. High-Tc Thin Films and Single Crystals |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
457-462 |
|
|
Keywords |
YBCO HTS detectors |
|
|
Abstract |
Radiation-induced change of the resistance was studied in the resistive state of YBaCuO films. Electron-phonon relaxation time T h was determmed from direct ep measurements and analysis of quasistationary electron heating. Temperature dependence of That TS 40 K was found to – ep be T h.. T'. The resul ts show that ep detectors with the response time of few picosecond at nitrogen temperature can be realized. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
Gorzkowski, W.; Gutowski, M.; Reich, A.; Szymczak, H. |
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
European Conference , Ustroń, Poland , 30 Sept – 4 Oct 1989 |
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1695 |
|
Permanent link to this record |
|
|
|
|
Author |
Rubtsova, I.; Korneev, A.; Matvienko, V.; Chulkova, G.; Milostnaya, I.; Goltsman, G.; Pearlman, A.; Slysz, W.; Verevkin, A.; Sobolewski, R. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Spectral sensitivity, quantum efficiency, and noise equivalent power of NbN superconducting single-photon detectors in the IR range |
Type |
Conference Article |
|
Year |
2004 |
Publication |
Proc. 29th IRMMW / 12th THz |
Abbreviated Journal |
Proc. 29th IRMMW / 12th THz |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
461-462 |
|
|
Keywords |
NbN SSPD, SNSPD |
|
|
Abstract |
We have developed nanostructured NbN superconducting single-photon detectors capable of GHz-rate photon counting in the 0.4 to 5 /spl mu/m wavelength range. Quantum efficiency of 30%, dark count rate 3/spl times/10/sup -4/ s/sup -1/, and NEP=10/sup -20/ W/Hz/sup -1/2/ have been measured at the 1.3-/spl mu/m wavelength for the device operating at 2.0 K. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1507 |
|
Permanent link to this record |
|
|
|
|
Author |
Verevkin, A.; Xu, Y.; Zheng, X.; Williams, C.; Sobolewski, Roman; Okunev, O.; Smirnov, K.; Chulkova, G.; Korneev, A.; Lipatov, A.; Gol’tsman, G. N. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Superconducting NbN-based ultrafast hot-electron single-photon detector for infrared range |
Type |
Conference Article |
|
Year |
2001 |
Publication |
Proc. 12th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 12th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
462-468 |
|
|
Keywords |
NbN SSPD, SNSPD |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1539 |
|
Permanent link to this record |
|
|
|
|
Author |
Baryshev, A.; Baselmans, J. J. A.; Reker, S. F.; Hajenius, M.; Gao, J. R.; Klapwijk, T. M.; Vachtomin, Yu.; Maslennikov, S.; Antipov, S.; Voronov, B.; Gol'tsman, G. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Direct detection effect in hot electron bolometer mixers |
Type |
Abstract |
|
Year |
2005 |
Publication |
Proc. 16th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 16th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
463-464 |
|
|
Keywords |
NbN HEB mixers, effect of direct detection, direct detection effect |
|
|
Abstract |
NbN phonon cooled hot electron bolometer (HEB) mixers are currently the most sensitive heterodyne detectors at frequencies above 1.2 THz. They combine a good sensitivity (8-15 times the quantum limit), an IF bandwidth of the order of 4-6 GHz and a wide RF bandwidth from 0.7-5.2 THz. However, for use in a space based observatory, such as Herschel, it is of vital importance that the Local Oscillator (LO) power requirement of the mixer is compatible with the low output power of present day THz LO sources. This can be achieved by reducing the mixer volume and critical current. However, the large RF bandwidth and low LO power requirement of such a mixer result in a direct detection effect, characterized by a change in the bias current of the HEB when changing the RF signal from a black body load at 300 K to one at 77 K. As a result the measured sensitivity using a 300 K and 77 K calibration load differs significantly from the small signal sensitivity relevant for astronomical observations. In this article we describe a set of dedicated experiments to characterize the direct detection effect for a small volume quasi-optical NbN phonon cooled HEB mixer. We measure the direct detection effect in a small volume (0.15 μm · 1 μm · 3.5 nm) quasi- optical NbN phonon cooled HEB mixer at 1.6 THz. We found that the small signal sensitivity of the receiver is underestimated by approximately 35% due to the direct detection effect and that the optimal operating point is shifted to higher bias voltages when using calibration loads of 300 K and 77 K. Using a 200 GHz wide band-pass filter at the 4.2 K the direct detection effect virtually disappears. Heterodyne response measurements using water vapor absorption line in a gas cell confirms the existence and a magnitude of a direct detection effect. We also propose a theoretical explanation using uniform electron heating model. This direct detection effect has important implications for the calibration procedure of these receivers in real telescope systems. We are developing Nb HEBs for a large-format, diffusion-cooled hot electron bolometer (HEB) array submillimeter camera. The goal is to produce a 64 pixel array together with the University of Arizona to be used on the HHT on Mt Graham. It is designed to detect in the 850 GHz atmospheric window. We have fabricated Nb HEBs using a new angle- deposition process, which had previously produced high quality Nb-Au bilayer HEB devices at Yale. [1] We have characterized these devices using heterodyne mixing at ~30 GHz to compare to 345 GHz tests at the University of Arizona. We can also directly compare our Nb HEB mixers to SIS mixers in this same 345 GHz system. This allows us to rigorously calibrate the system’s losses and extract the mixer noise temperature in a well characterized mixer block, before undertaking the 850 GHz system. Here we give a report on the initial devices we have fabricated and characterized. * Department of Applied Physics, Yale University ** Department of Astronomy, University of Arizona [1] Applied Physics Letters 84, Number 8; p.1404-7, Feb 23 (2004) |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1475 |
|
Permanent link to this record |
|
|
|
|
Author |
Moshkova, M. A.; Divochiy, A. V.; Morozov, P. V.; Antipov, A. V.; Vakhtomin, Yu. B.; Smirnov, K. V. |
![find book details (via ISBN) isbn](img/isbn.gif)
|
|
Title |
Characterization of topologies of superconducting photon number resolving detectors |
Type |
Conference Article |
|
Year |
2019 |
Publication |
Proc. 8th Int. Conf. Photonics and Information Optics |
Abbreviated Journal |
Proc. 8th Int. Conf. Photonics and Information Optics |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
465-466 |
|
|
Keywords |
PNR SSPD |
|
|
Abstract |
Comparative analysis for different topologies of superconducting single-photon detectors with ability to resolve up to 4 photons in a short pulse of IR radiation has been carry out. It was developed the detector with a system detection efficiency of ~ 85 % at λ = 1550 nm. The possibility of using such detector to restore photon statistics of a pulsed radiation source was demonstrated. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
Russian |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
978-5-7262-2536-4 |
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
http://fioconf.mephi.ru/files/2018/12/FIO2019-Sbornik.pdf |
Approved |
no |
|
|
Call Number |
|
Serial |
1803 |
|
Permanent link to this record |
|
|
|
|
Author |
Gol'tsman, Gregory; Semenov, Alexei; Smirnov, Konstantin; Voronov, Boris |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Background limited quantum superconducting detector for submillimeter wavelengths |
Type |
Conference Article |
|
Year |
2001 |
Publication |
Proc. 12th Int. Symp. Space Terahertz Technol. |
Abbreviated Journal |
Proc. 12th Int. Symp. Space Terahertz Technol. |
|
|
Volume |
|
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
469-475 |
|
|
Keywords |
Ti SQD, SQUID readout |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
|
Serial |
1540 |
|
Permanent link to this record |