Semenov, A., Engel, A., Il'in, K., Gol'tsman, G., Siegel, M., & Hübers, H. - W. (2003). Ultimate performance of a superconducting quantum detector. Eur. Phys. J. Appl. Phys., 21(3), 171–178.
Abstract: We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.
|
|
|
Semenov, A. D., Hübers, H. - W., Richter, H., Birk, M., Krocka, M., Mair, U., et al. (2003). Superconducting hot-electron bolometer mixer for terahertz heterodyne receivers. IEEE Trans. Appl. Supercond., 13(2), 168–171.
Abstract: We present recent results showing the development of superconducting NbN hot-electron bolometer mixer for German receiver for astronomy at terahertz frequencies and terahertz limb sounder. The mixer is incorporated into a planar feed antenna, which has either logarithmic spiral or double-slot configuration, and backed on a silicon lens. The hybrid antenna had almost frequency independent and symmetric radiation pattern slightly broader than expected for a diffraction limited antenna. At 2.5 THz the best 2200 K double side-band receiver noise temperature was achieved across a 1 GHz intermediate frequency bandwidth centred at 1.5 GHz. For this operation regime, a receiver conversion efficiency of -17 dB was directly measured and the loss budget was evaluated. The mixer response was linear at load temperatures smaller than 400 K. Implementation of the MgO buffer layer on Si resulted in an increased 5.2 GHz gain bandwidth. The receiver was tested in the laboratory environment by measuring a methanol emission line at 2.5 THz.
|
|
|
Gershenzon, E. M., Gol'tsman, G. N., & Semenov, A. D. (1983). Submillimeter backward wave tube spectrometer for measuring superconducting film transmission. Pribory i Tekhnika Eksperimenta, 26(5), 134–137.
Abstract: A spectrometer employing six backward wave tubes is described. It is intended for investigation of superconductors in the 0.2-3 mm range of wave lengths. During the measurement of the transmission spectrum it is possible to determine the energy gap for superconduct1ng films 50 to 4000 A thick. The transmission factor can vary from 10-1 to 10-9. Spectrum of relation of film transmission factors in superconducting and normal states is measured for determining the energy gap 2 Δ. The transmission spectrum obtained by means of a computer for vanadium film 300 A thick is given as an example. The energy gap 2 Δ = 1.4 MeV
|
|
|
Aksaev, E. E., Gershenzon, E. M., Gol'tsman, G. N., Mirskij, G. I., & Semenov, A. D. (1991). Submillimetric spectrometer-relaxometer based on backward-wave tubes with picosecond time resolution. Pribory i Tekhnika Eksperimenta, 34(2), 125–131.
Abstract: The high-sensitive automatic spectrometer-relaxometer based on backward-wave tubes in the range of 4÷0.25 mm was described permitting to study the response kinetics of sample under investigation in any point of this range with the resolution time of 10-11 s. The relaxation measurements were conducted using oscillation beats of two adequate tubes, the frequency of one of them was fixed, while that of the other one was changeable. The amplitude-frequency characteristic of the response under the conditions of synchronous reception was recorded at beat frequency variation from 107 to 1010 Hz. The high sensitivity was reached by decreasing the device recording band down to 100 Hz in the whole measuring range.
|
|
|
Cherednichenko, S., Drakinskiy, V., Baubert, J., Lecomte, B., Dauplay, F., Krieg, J. - M., et al. (2007). 2.5 THz multipixel heterodyne receiver based on NbN HEB mixers. In Proc. 18th Int. Symp. Space Terahertz Technol. (112).
Abstract: A 16 pixel heterodyne receiver for 2.5 THz has been developed based on NbN superconducting hot-electron bolometer (HEB) mixers. The receiver uses a quasioptical RF coupling approach where HEB mixers are integrated into double dipole antennas on 1.5μm thick Si3N4 / SiO2 membranes. Spherical mirrors (one per pixel) and backshort distance from the antenna have been used to design the output mixer beam profile. The camera design allows all 16 pixel IF readout in parallel. Measurements of the mixers sensitivity and the input RF band are presented, and compared against calculations.
|
|
|
Tovpeko, N. A., Trifonov, A. V., Semenov, A. V., Antipov, S. V., Kaurova, N. S., Titova, N. A., et al. (2019). Bandwidth performance of a THz normal metal TiN bolometer-mixer. In Proc. 30th Int. Symp. Space Terahertz Technol. (pp. 102–103).
Abstract: We report on the bandwidth performance of the normal metal TiN bolometer-mixer on top of an Al 2 O 3 substrate, which is capable to operate in a wide range of bath temperatures from 77 K – 300 K. The choice of the combination TiN / Al 2 O 3 is related to an advanced heat transport between the film and the substrate in this pair and the sufficient temperature coefficient of resistance. The data were taken at 132.5 – 145.5 GHz with two BWOs as a signal and an LO source. Measurements were taken on TiN films of different thickness starting from 20 nm down to 5 nm coupled into a spiral Au antenna, which improves matching of incoming radiation with the thin TiN fim. Our experiments demonstrate effective heat coupling from a TiN thin film to an Al 2 O 3 substrate (111) boosting gain bandwidth (GB) of TiN bolometer up to 6 GHz for 5 nm thin film. Current results indicate weak temperature dependence of GB on the bath temperature of the TiN bolometer. Theoretical estimations of GB performance meet with experimental data for 5 nm thin TiN films.
|
|
|
Nebosis, R. S., Heusinger, M. A., Semenov, A. D., Lang, P. T., Schatz, W., Steinke, R., et al. (1993). Ultrafast photoresponse of an YBa2Cu3O7-δ film to far-infrared radiation pulses. Opt. Lett., 18(2), 96–97.
Abstract: We report the observation of an ultrafast photoresponse of a high-T(c), film to far-infrared radiation pulses. The response of a sample, consisting of a current-carrying structured YBa(2)Cu(3)O(7-delta) film cooled to liquid-nitrogen temperature, was studied by use of ultrashort laser pulses from an optically pumped far-infrared laser in the frequency range from 0.7 to 7 THz. We found that the response time was limited by the time resolution, 120 ps, of our electronic registration equipment.
|
|
|
Aksaev, E. E., Gershenzon, E. M., Gershenson, M. E., Goltsman, G. N., Semenov, A. D., & Sergeev, A. V. (1989). Prospects for using high-temperature superconductors to create electron bolometers. Pisma v Zhurnal Tekhnicheskoi Fiziki, 15(14), 88–93.
|
|
|
Gershenzon, E. M., Gershenson, M. E., Goltsman, G. N., Karasik, B. S., Lyulkin, A. M., & Semenov, A. D. (1989). Fast-response superconducting electron bolometer. Pisma v Zhurnal Tekhnicheskoi Fiziki, 15(3), 88–92.
Abstract: The general design, operation, and performance characteristics of fast-response electronic bolometers using a thin superconducting Nb film on a leucosapphire substrate are briefly reviewed. The volt-watt sensitivity of the bolometrs is 2,000-200,000 V/W, the operating temperature is 1.6 K, and the time constant is 4-4.5 ns.
|
|
|
Yagoubov, P., Hübers, H. - W., Gol’tsman, G., Semenov, A., Gao, J., Hoogeveen, R., et al. (2001). Hot-electron bolometer mixers – technology for far-infrared heterodyne instruments in future atmospheric chemistry missions. In S. Buehler, & Berlin (Eds.), Proc. 3rd Int. Symp. Submillimeter Wave Earth Observation From Space (pp. 57–69). Logos-Verlag.
|
|