|
Manova, N. N., Smirnov, E. O., Korneeva, Y. P., Korneev, A. A., & Goltsman, G. N. (2019). Superconducting photon counter for nanophotonics applications. In J. Phys.: Conf. Ser. (Vol. 1410, 012147 (1 to 5)).
Abstract: We develop large area superconducting single-photon detector SSPD with a micron-wide strip suitable for free-space coupling or packaging with multi-mode optical fibres. The detector sensitive area is 20 μm in diameter. In near infrared (1330 nm wavelength) our SSPD exhibits above 30% detection efficiency with low dark counts and 45 ps timing jitter.
|
|
|
Polyakova, M. I., Korneev, A. A., & Semenov, A. V. (2020). Comparison single- and double- spot detection efficiencies of SSPD based to MoSi and NbN films. In J. Phys.: Conf. Ser. (Vol. 1695, 012146 (1 to 3)).
Abstract: In this work, we present results of quantum detector tomography of superconducting single photon detector (SSPD) based on MoSi film, and compare them with previously reported data on NbN. We find that for both materials hot spot interaction length coincides with the strip width, and the dependence of single and double-spot detection efficiencies on bias current are compatible with sufficiently large hot-spot size, approaching the strip width.
|
|
|
Gayduchenko, I. A., Fedorov, G. E., Stepanova, T. S., Titova, N., Voronov, B. M., But, D., et al. (2016). Asymmetric devices based on carbon nanotubes as detectors of sub-THz radiation. In J. Phys.: Conf. Ser. (Vol. 741, 012143 (1 to 6)).
Abstract: Demand for efficient terahertz (THz) radiation detectors resulted in intensive study of the asymmetric carbon nanostructures as a possible solution for that problem. In this work, we systematically investigate the response of asymmetric carbon nanodevices to sub-terahertz radiation using different sensing elements: from dense carbon nanotube (CNT) network to individual CNT. We conclude that the detectors based on individual CNTs both semiconducting and quasi-metallic demonstrate much stronger response in sub-THz region than detectors based on disordered CNT networks at room temperature. We also demonstrate the possibility of using asymmetric detectors based on CNT for imaging in the THz range at room temperature. Further optimization of the device configuration may result in appearance of novel terahertz radiation detectors.
|
|
|
Shcherbatenko, M., Elezov, M., Sych, D., & Goltsman, G. N. (2020). Optimal fiber optic scheme for sub-SQL quantum receiver realization. In J. Phys.: Conf. Ser. (Vol. 1695, 012140).
Abstract: Practical implementation of high-precision quantum measurements is an important problem in modern science. One of the main parts of the quantum receiver is the optical scheme. We developed and tested several optical circuits based on different types of interferometers, namely Sagnac-based scheme, Mach-Zehnder-based scheme, and Michelson-based scheme. All these schemes are assembled with optical fibers and fiber-optic components, since the fiber-optic implementation is closest to application in practical devices. Schemes were evaluated according to two main criteria: extinction and interference stability. On the basis of the obtained data, it can be concluded that the most suitable is the scheme based on the Mach-Zehnder interferometer. In continuous mode, we were able to obtain an interference extinction about 30 dB with acceptable temporal stability.
|
|
|
Moshkova, M., Morozov, P., Divochiy, A., Vakhtomin, Y., & Smirnov, K. (2019). Large active area superconducting single photon detector. In J. Phys.: Conf. Ser. (Vol. 1410, 012139).
Abstract: We present development of large active area superconducting single-photon detectors well coupled with standard 50 μm-core multi-mode fiber. The sensitive area of the SSPD is patterned using the photon-number-resolving design and occupies an area of 40×40 μm2. Using this approach, we have obtained excellent specifications: system detection efficiency of 47% measured using a 900 nm laser and low dark count rate of 100 cps. The main advantages of the approach presented are a very short dead time of the detector of 22 ns and FWHM jitter value of about 130 ps.
|
|