Kovalyuk, V., Hartmann, W., Kahl, O., Kaurova, N., Korneev, A., Goltsman, G., et al. (2013). Absorption engineering of NbN nanowires deposited on silicon nitride nanophotonic circuits. Opt. Express, 21(19), 22683–22692.
Abstract: We investigate the absorption properties of U-shaped niobium nitride (NbN) nanowires atop nanophotonic circuits. Nanowires as narrow as 20nm are realized in direct contact with Si3N4 waveguides and their absorption properties are extracted through balanced measurements. We perform a full characterization of the absorption coefficient in dependence of length, width and separation of the fabricated nanowires, as well as for waveguides with different cross-section and etch depth. Our results show excellent agreement with finite-element analysis simulations for all considered parameters. The experimental data thus allows for optimizing absorption properties of emerging single-photon detectors co-integrated with telecom wavelength optical circuits.
|
Shurakov, A., Lobanov, Y., & Goltsman, G. (2015). Superconducting hot-electron bolometer: from the discovery of hot-electron phenomena to practical applications. Supercond. Sci. Technol., 29(2), 023001.
Abstract: The discovery of hot-electron phenomena in a thin superconducting film in the last century was followed by numerous experimental studies of its appearance in different materials aiming for a better understanding of the phenomena and consequent implementation of terahertz detection systems for practical applications. In contrast to the competitors such as superconductor-insulator-superconductor tunnel junctions and Schottky diodes, the hot electron bolometer (HEB) did not demonstrate any frequency limitation of the detection mechanism. The latter, in conjunction with a decent performance, rapidly made the HEB mixer the most attractive candidate for heterodyne observations at frequencies above 1 THz. The successful operation of practical instruments (the Heinrich Hertz Telescope, the Receiver Lab Telescope, APEX, SOFIA, Hershel) ensures the importance of the HEB technology despite the lack of rigorous theoretical routine for predicting the performance. In this review, we provide a summary of experimental and theoretical studies devoted to understanding the HEB physics, and an overview of various fabrication routes and materials.
|
Shangina, E. L., Smirnov, K. V., Morozov, D. V., Kovalyuk, V. V., Goltsman, G. N., Verevkin, A. A., et al. (2011). Concentration dependence of energy relaxation time in AlGaAs/GaAs heterojunctions: direct measurements. Semicond. Sci. Technol., 26(2), 025013.
Abstract: We present measurements of the energy relaxation time, τε, of electrons in a single heterojunction in a quasi-equilibrium state using microwave time-resolved spectroscopy at 4.2 K. We find the relaxation time has a power-law dependence on the carrier density of the two-dimensional electron gas, τε∝nγs with γ = 0.40 ± 0.02 for values of the carrier density, ns, from 1.6 × 1011 to 6.6 × 1011cm−2. The results are in good agreement with predictions taking into account the scattering of the carriers by both piezoelectric and deformation potential acoustic phonons. We compare these results with indirect measurements of the energy relaxation time from energy loss measurements involving Joule heating of the electron gas.
|
Gayduchenko, I. A., Moskotin, M. V., Matyushkin, Y. E., Rybin, M. G., Obraztsova, E. D., Ryzhii, V. I., et al. (2018). The detection of sub-terahertz radiation using graphene-layer and graphene-nanoribbon FETs with asymmetric contacts. In Materials Today: Proc. (Vol. 5, pp. 27301–27306).
Abstract: We report on the detection of sub-terahertz radiation using single layer graphene and graphene-nanoribbon FETs with asymmetric contacts (one is the Schottky contact and one – the Ohmic contact). We found that cutting graphene into ribbons a hundred nanometers wide leads to a decrease of the response to sub-THz radiation. We show that suppression of the response in the graphene nanoribbons devices can be explained by unusual properties of the Schottky barrier on graphene-vanadium interface.
|
Shcherbatenko, M., Lobanov, Y., Semenov, A., Kovalyuk, V., Korneev, A., Ozhegov, R., et al. (2016). Potential of a superconducting photon counter for heterodyne detection at the telecommunication wavelength. Opt. Express, 24(26), 30474–30484.
Abstract: Here, we report on the successful operation of a NbN thin film superconducting nanowire single-photon detector (SNSPD) in a coherent mode (as a mixer) at the telecommunication wavelength of 1550 nm. Providing the local oscillator power of the order of a few picowatts, we were practically able to reach the quantum noise limited sensitivity. The intermediate frequency gain bandwidth (also referred to as response or conversion bandwidth) was limited by the spectral band of a single-photon response pulse of the detector, which is proportional to the detector size. We observed a gain bandwidth of 65 MHz and 140 MHz for 7 x 7 microm2 and 3 x 3 microm2 devices, respectively. A tiny amount of the required local oscillator power and wide gain and noise bandwidths, along with unnecessary low noise amplification, make this technology prominent for various applications, with the possibility for future development of a photon counting heterodyne-born large-scale array.
|
Elezov, M., Ozhegov, R., Goltsman, G., & Makarov, V. (2019). Countermeasure against bright-light attack on superconducting nanowire single-photon detector in quantum key distribution. Opt. Express, 27(21), 30979–30988.
Abstract: We present an active anti-latching system for superconducting nanowire single-photon detectors. We experimentally test it against a bright-light attack, previously used to compromise security of quantum key distribution. Although our system detects continuous blinding, the detector is shown to be partially blindable and controllable by specially tailored sequences of bright pulses. Improvements to the countermeasure are suggested.
|
Shcherbatenko, M. L., Elezov, M. S., Goltsman, G. N., & Sych, D. V. (2020). Sub-shot-noise-limited fiber-optic quantum receiver. Phys. Rev. A, 101(3), 032306 (1 to 5).
Abstract: We experimentally demonstrate a quantum receiver based on the Kennedy scheme for discrimination between two phase-modulated weak coherent states. The receiver is assembled entirely from standard fiber-optic elements and operates at a conventional telecom wavelength of 1.55 μm. The local oscillator and the signal are transmitted through different optical fibers, and the displaced signal is measured with a high-efficiency superconducting nanowire single-photon detector. We show the discrimination error rate is two times below that of a shot-noise-limited receiver with the same system detection efficiency.
|
Lusche, R., Semenov, A., Ilin, K., Siegel, M., Korneeva, Y., Trifonov, A., et al. (2014). Effect of the wire width on the intrinsic detection efficiency of superconducting-nanowire single-photon detectors. J. Appl. Phys., 116(4), 043906 (1 to 9).
Abstract: A thorough spectral study of the intrinsic single-photon detection efficiency in superconducting TaN and NbN nanowires with different widths has been performed. The experiment shows that the cut-off of the intrinsic detection efficiency at near-infrared wavelengths is most likely controlled by the local suppression of the barrier for vortex nucleation around the absorption site. Beyond the cut-off quasi-particle diffusion in combination with spontaneous, thermally activated vortex crossing explains the detection process. For both materials, the reciprocal cut-off wavelength scales linearly with the wire width where the scaling factor agrees with the hot-spot detection model.
|
Elezov, M. S., Scherbatenko, M. L., Sych, D. V., & Goltsman, G. N. (2018). Active and passive phase stabilization for the all-fiber Michelson interferometer. In J. Phys.: Conf. Ser. (Vol. 1124, 051014 (1 to 5)).
Abstract: We put forward two methods for phase stabilization in the all-fiber Michelson interferometer. To perform passive phase stabilization, we use a heat bath for all fibers and electro-optical components, and put the interferometer in a hermetic case. To perform active phase stabilization, we monitor output power of the interferometer and develop an electronic feedback control. The phase stabilization methods enable stable interference pattern for several minutes, and can be helpful for the development of the optimal quantum receiver for coherent signals.
|
Smirnov, E., Golikov, A., Zolotov, P., Kovalyuk, V., Lobino, M., Voronov, B., et al. (2018). Superconducting nanowire single-photon detector on lithium niobate. In J. Phys.: Conf. Ser. (Vol. 1124, 051025).
Abstract: We demonstrate superconducting niobium nitride nanowires folded on top of lithium niobate substrate. We report of 6% system detection efficiency at 20 s−1 dark count rate at telecommunication wavelength (1550 nm). Our results shown great potential for the use of NbN nanowires in the field of linear and nonlinear integrated quantum photonics.
|