|
Ryabchun, S., Tong, C. - Y. E., Blundell, R., & Gol'tsman, G. (2009). Stabilization scheme for hot-electron bolometer receivers using microwave radiation. IEEE Trans. Appl. Supercond., 19(1), 14–19.
Abstract: We present the results of a stabilization scheme for terahertz receivers based on NbN hot-electron bolometer (HEB) mixers that uses microwave radiation with a frequency much lower than the gap frequency of NbN to compensate for mixer current fluctuations. A feedback control loop, which actively controls the power level of the injected microwave radiation, has successfully been implemented to stabilize the operating point of the HEB mixer. This allows us to increase the receiver Allan time to 10 s and also improve the temperature resolution of the receiver by about 30% in the total power mode of operation.
|
|
|
Semenov, A. D., Gol'tsman, G. N., & Sobolewski, R. (2002). Hot-electron effect in superconductors and its applications for radiation sensors. Supercond. Sci. Technol., 15(4), R1–R16.
Abstract: The paper reviews the main aspects of nonequilibrium hot-electron phenomena in superconductors and various theoretical models developed to describe the hot-electron effect. We discuss implementation of the hot-electron avalanche mechanism in superconducting radiation sensors and present the most successful practical devices, such as terahertz mixers and direct intensity detectors, for far-infrared radiation. Our presentation also includes the novel approach to hot-electron quantum detection implemented in superconducting x-ray to optical photon counters.
|
|
|
Shurakov, A., Tong, E., Blundell, R., & Gol'tsman, G. (2012). Microwave stabilization of HEB mixer by a microchip controller. In IEEE MTT-S international microwave symposium digest (pp. 1–3).
Abstract: The stability of a Hot Electron Bolometer (HEB) mixer can be improved by the use of microwave injection. In this article we report a refinement of this approach. We introduce a microchip controller to facilitate the implementation of the stabilization scheme, and demonstrate that the feedback loop effectively suppresses drifts in the HEB bias current, leading to an improvement in the receiver stability. The measured Allan time of the mixer's IF output power is increased to > 10 s.
|
|
|
Beck, M., Leiderer, P., Kabanov, V. V., Gol'tsman, G., Helm, M., & Demsar, J. (2012). Energy-gap dynamics of a superconductor NbN studied by time-resolved terahertz spectroscopy. In INIS (Vol. 45, pp. 1–3).
Abstract: Using time-resolved terahertz (THz) spectroscopy we performed direct studies of the photoinduced suppression and recovery of the SC gap in a conventional SC NbN. Both processes are found to be strongly temperature and excitation density dependent. The analysis of the data with the established phenomenological Rothwarf-Taylor model enabled us to determine the important microscopic constants: the Cooper pair-breaking rate via phonon absorption and the bare quasiparticle recombination rate. From the latter we were able to extract the dimensionless electron-phonon coupling constant, λ=1.1±0.1, in excellent agreement with theoretical estimates. The technique also allowed us to determine the absorbed energy required to suppress SC, which in NbN equals the thermodynamic condensation energy (in cuprates the two differ by an order of magnitude). Finally, we present the first studies of dynamics following resonant excitation with intense narrow band THz pulses tuned to above and below the superconducting gap. These suggest an additional process, particularly pronounced near Tc, that could be attributed to amplification of SC via effective quasiparticle cooling.
|
|
|
Marsili, F., Bitauld, D., Fiore, A., Gaggero, A., Mattioli, F., Leoni, R., et al. (2010). Photon-number-resolution at telecom wavelength with superconducting nanowires. IntechOpen [DOI:10.5772/6920]. Retrieved September 27, 2024, from http://dx.doi.org/10.5772/6920
|
|
|
Semenov, A., Hübers, H. - W., Engel, A., & Gol'tsman, G. N. (2002). Background limited superconducting quantum detector for astronomy. In NASA/ADS.
Abstract: We present the concept of the superconducting quantum detector for astronomy. Response to a single absorbed photon appears due to successive formation of a normal spot and phase-slip-centers in a narrow strip carrying sub-critical supercurrent. The detector simultaneously has a moderate energy resolution and a variable cut-off wavelength depending on both the material used and operation conditions. We simulated performance of the background-limited direct detector having the 100- micrometer cut-off wavelength. Low dark count rate will allow to realize 10-21 W Hz-1/2 noise equivalent power at 4 K background radiation. The intrinsic recovery time of the counter is rather determined by diffusion of nonequilibrium electrons, thus, thermal fluctuations do not hamper energy resolution of the detector. Provided an appropriate readout technique, the resolution should be better than 1/20 at 50- micrometer wavelength. Planar layout and relatively simple technology favor integration of the detector into an array.
|
|