|   | 
Details
   web
Records
Author Karasik, B.S.; Lindgren, M.; Zorin, M.A.; Danerud, M.; Winkler, D.; Trifonov, V.V.; Gol’tsman, G.N.; Gershenzon, E.M.
Title Picosecond detection and broadband mixing of near-infrared radiation by YBaCuO films Type Conference Article
Year 1994 Publication Proc. SPIE Abbreviated Journal Proc. SPIE
Volume 2159 Issue Pages (up) 68-76
Keywords YBCO HTS HEB mixer
Abstract Nonequilibrium picosecond and bolometric responses of YBCO films 500 angstroms thick patterned into 20 X 20 micrometers 2 size structure to 17 ps laser pulses and modulated radiation of GaAs and CO2 lasers have been studied. The modulation frequencies up to 10 GHz for GaAs laser and up to 1 GHz for CO2 were attained. The use of small radiation power (1 – 10 mW/cm2 for cw radiation and 10 – 100 nJ/cm2 for pulse radiation) in combination with high sensitive read-out system made possible to avoid any non-linear transient processes caused by an overheating of sample above a critical temperature or S-N switching enhanced by an intense radiation. Responses due to the change of kinetic inductance were believed to be negligible. The only signals observed were caused by a small change of the film resistance either in the resistive state created by a bias current or in the normal state. The data obtained by means of pulse and modulation techniques are in agreement. The responsivity about 1 V/W was measured at 1 GHz modulation frequency both for 0.85 micrometers and 10.6 micrometers wavelengths. The sensitivity of high-Tc fast wideband infrared detector is discussed.
Address
Corporate Author Thesis
Publisher Spie Place of Publication Editor Nahum, M.; Villegier, J.-C.
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference High-Temperature Superconducting Detectors: Bolometric and Nonbolometric
Notes Approved no
Call Number Serial 1640
Permanent link to this record
 

 
Author Neroev, V. V.; Iomdina, E. N.; Khandzhyan, A. T.; Khodzhabekyan, N. V.; Sengaeva, M. D.; Ivanova, A. V.; Seliverstov, S. V.; Teplyakova, K. O.; Goltsman, G. N.
Title Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy Type Journal Article
Year 2021 Publication Vestn. Oftalmol. Abbreviated Journal Vestn. Oftalmol.
Volume 137 Issue 3 Pages (up) 68-75
Keywords THz scanning, cornea, photorefractive keratectomy, medicine
Abstract Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.

Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.

Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).

Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).

Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Russian Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1794
Permanent link to this record
 

 
Author Galin, I.; Schnitzer, C. A.; Dengler, R. J.; Quintero, O.
Title 177–207 GHz radiometer front end, single–side–band measurements Type Conference Article
Year 1999 Publication Proc. 10th Int. Symp. Space Terahertz Technol. Abbreviated Journal
Volume Issue Pages (up) 70
Keywords
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Charlottesville, Virginia, USA Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number RPLAB @ s @ schottky_Tn_1000_at_0p2THz Serial 289
Permanent link to this record
 

 
Author Fedorov, G.; Kardakova, A.; Gayduchenko, I.; Voronov, B. M.; Finkel, M.; Klapwijk, T. M.; Goltsman, G.
Title Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-THz radiation Type Abstract
Year 2014 Publication Proc. 25th Int. Symp. Space Terahertz Technol. Abbreviated Journal Proc. 25th Int. Symp. Space Terahertz Technol.
Volume Issue Pages (up) 71
Keywords carbon nanotubes, CNT
Abstract This work reports on the voltage response of asymmetric carbon nanotube devices to sub-THz radiation at the frequency of 140 GHz. The devices contain CNT’s, which are over their length partially suspended and partially Van der Waals bonded to a SiO 2 substrate, causing a difference in thermal contact. Different heat sinking of CNTs by source and drain gives rise to temperature gradient and consequent thermoelectric power (TEP) as such a device is exposed to the sub-THz radiation. Sign of the DC signal, its power and gate voltage dependence observed at room temperature are consistent with this scenario. At liquid helium temperature the observed response is more complex. DC voltage signal of an opposite sign is observed in a narrow range of gate voltages at low temperatures and under low radiation power. We argue that this may indicate a true photovoltaic response from small gap (less than 10meV) CNT’s, an effect never reported before. While it is not clear if the observed effects can be used to develop efficient THz detectors we note that the responsivity of our devices exceeds that of CNT based devices in microwave or THz range reported before at room temperature. Besides at 4.2 K notable increase of the sample conductance (at least four-fold) is observed. Our recent results with asymmetric carbon nanotube devices response to THz radiation (2.5 THz) will also be presented.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1361
Permanent link to this record
 

 
Author Korneev, A.; Korneeva, Y.; Florya, I.; Voronov, B.; Goltsman, G.
Title NbN nanowire superconducting single-photon detector for mid-infrared Type Journal Article
Year 2012 Publication Phys. Procedia Abbreviated Journal Phys. Procedia
Volume 36 Issue Pages (up) 72-76
Keywords NbN SSPD, SNSPD
Abstract Superconducting single-photon detectors (SSPD) is typically 100 nm-wide supercondiucting strip in a shape of meander made of 4-nm-thick film. To reduce response time and increase voltage response a parallel connection of the strips was proposed. Recently we demonstrated that reduction of the strip width improves the quantum effciency of such a detector at wavelengths longer than 1.5 μm. Being encourage by this progress in quantum effciency we improved the fabrication process and made parallel-wire SSPD with 40-nm-wide strips covering total area of 10 μm x 10 μm. In this paper we present the results of the characterization of such a parallel-wire SSPD at 10.6 μm wavelength and demonstrate linear dependence of the count rate on the light power as it should be in case of single-photon response.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1875-3892 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 1382
Permanent link to this record