Hoogeveen, R. W. M., Yagoubov, P. A., Maurellis, A., Koshelets, V. P., Shitov, S. V., Mair, U., et al. (2003). New cryogenic heterodyne techniques applied in TELIS: the balloonborne THz and submillimeter limb sounder for atmospheric research. In M. Strojnik (Ed.), Proc. SPIE (Vol. 5152, pp. 347–355). SPIE.
Abstract: We present a design concept for a new state-of-the-art balloon borne atmospheric monitor that will allow enhanced limb sounding of the Earth’s atmosphere within the submillimeter and far-infrared wavelength spectral range: TELIS, TErahertz and submm LImb Sounder. The instrument is being developed by a consortium of major European institutes that includes the Space Research Organization of the Netherlands (SRON), the Rutherford Appleton Laboratory (RAL) will utilize state-of-the-art superconducting heterodyne technology and is designed to be a compact, lightweight instrument cpaable of providing broad spectral coverage, high spectral resolution and long flight duration ( 24 hours duration during a single flight campaign). The combination of high sensitivity and extensive flight duration will allow evaluation of the diurnal variation of key atmospheric constitutenets sucyh as OH, HO2, ClO, BrO togehter will onger lived constituents such as O3, HCL and N2O. Furthermore, TELIS will share a common balloon platform to that of the MIPAS-B Fourier Transform Spectrometer, developed by the Institute of Meteorology and Climate research of the over an extended spectral range. The combination of the TELIS and MIPAS instruments will provide atmospheric scientists with a very powerful observational tool. TELIS will serve as a testbed for new cryogenic heterodyne detection techniques, and as such it will act as a prelude to future spaceborne instruments planned by the European Space Agency (ESA).
|
Kuzin, A., Elmanov, I., Kovalyuk, V., An, P., & Goltsman, G. (2020). Silicon nitride focusing grating coupler for input and output light of NV-centers. In Proc. 32-nd EMSS (pp. 349–353).
Abstract: Here we presented the numerical results for the calculation of focusing grating coupler efficiency in the visible wavelength range. Using the finite element method, the optimal geometric parameters, including filling factor and grating period for a central wavelength of 637 nm, were found. Obtained results allow to input/output single-photon radiation from NV-centers, and can be used for research and development of a scalable on-chip quantum optical computing.
|
Loudkov, D., Tong, C. - Y. E., Marrone, D. P., Ryabchun, S., Paine, S. N., & Blundell, R. (2005). Transmission measurements of infrared filters for low-noise terahertz receiver applications. In Proc. 16th Int. Symp. Space Terahertz Technol. (pp. 354–357).
Abstract: Infrared (IR) filters are very important to the efficient operation of cryogenic receivers. Usually, such filters are mounted on the radiation shield of the cryostat to reduce the heat load to the 4 K stage. Insufficient filtering may cause the temperature of the mixing element in a receiver to be excessively warm, leading to degradation in sensitivity. These filters should be effective in blocking the room temperature IR radiation from outside the cryostat, yet should be transparent across the desired signal frequency band. In the Terahertz frequency range, which is close to the infrared, it is difficult to find an inexpensive low- loss material that can provide the required IR blocking capacity. We present transmission measurements, made using a Fourier Transform Spectrometer (FTS), of a number of potential infrared filters between 0.4 and 1.6 THz. The filters tested include the widely-used, Teflon-based, Zitex-A and Zitex-G films, alkali halide based infrared filter, and crystalline quartz coated with Parylene, and polyethylene films.
|
Elmanov, I., Elmanova, A., Kovalyuk, V., An, P., & Goltsman, G. (2020). Integrated contra-directional coupler for NV-centers photon filtering. In Proc. 32-nd EMSS (pp. 354–360).
Abstract: We modelled an integrated optical contra-directional coupler on silicon nitride platform. Performance of the filter was studied depending on different parameters, including the grating period and the height of teeth of the Bragg grating near 637 nm operation wavelength. The obtained results can be used for a design and fabrication of quantum photonic integrated circuits with on-chip single-photon NV-centers in nanodiamonds.
|
Yngvesson, K. S., Gerecht, E., Musante, C. F., Zhuang, Y., Ji, M., Goyette, T. M., et al. (1999). Low-noise HEB heterodyne receivers and focal plane arrays for the THz regime using NbN. In R. J. Hwu, & K. Wu (Eds.), Proc. SPIE (Vol. 3795, pp. 357–368). SPIE.
Abstract: We have developed prototype HEB receivers using thin film superconducting NbN devices deposited on silicon substrates. The devices are quasi-optically coupled through a silicon lens and a self-complementary log-specific toothed antenna. We measured DSB receiver noise temperatures of 500 K (13 X hf/2k) at 1.56 THz and 1,100 K (20 X hf/2k) at 2.24 THz. Noise temperatures are expected to fall further as devices and quasi-optical coupling methods are being optimized. The measured 3 dB IF conversion gain bandwidth for one device was 3 GHz, and it is estimated that the bandwidth over which the receiver noise temperature is within 3 dB of its minimum value is 6.5 GHz which is sufficient for a number of practical applications. We will discuss our latest results and give a detailed description of our prototype setup and experiments. We will also discuss our plans for developing focal plane arrays with tens of Hot Electron Bolometric mixer elements on a single silicon substrate which will make real time imaging systems in the THz region feasible.
|