Sergeev, A. V., Aksaev, E. E., Gogidze, I. G., Gol’tsman, G. N., Semenov, A. D., & Gershenzon, E. M. (1993). Thermal boundary resistance at YBaCuO film-substrate interface. In M. Meissner, & R. O. Pohl (Eds.), Phonon Scattering in Condensed Matter VII. Springer Series in Solid-State Sciences (Vol. 112, pp. 405–406).
Abstract: The nanosecond voltage response of YBaCuo films on Al2O3, MgO and ZrO2 substrates to electromagnetic radiation of millimeter and visible ranges has been investigated. The analysis of experimental conditions for Al2O3 and MgO substrates shows that the resistance change is monitored by the Kapitza boundary shift of temperature during the temporal interval ~ 100 ns limited by the time of phonon return from a substrate into a film. The observed exponential voltage decay is described by the phonon escape time which is proportional to the film thickness and is weakly temperature dependent.
|
Симонов, Н. О., Флоря, И. Н., Корнеева, Ю. П., Корнеев, А. А., & Гольцман, Г. Н. (2018). Однофотонный отклик в тонких сверхпроводящих MoNx пленках. In Сборн. науч. труд. VII международн. конф. по фотонике и информац. опт. (pp. 408–409).
Abstract: Продемонстрирован однофотонный отклик, при токе близком к критическому, в MoNx сверхпроводящих полосках шириной 70-104 нм. MoNx детекторы, имеющие коэффициент диффузии D≈0.32 см2/с и время электрон-фононного взаимодействия ηe-ph≈300 пс, достигают квантовой эффективности QE≈20% на длине волны λ=1550 нм. Возможность реализации однофотонного детектора в данном материале, подтверждает существующую теорию вихревого механизма возникновения фотоотклика в узких сверхпроводящих полосках.
|
Boyarskii, D. A., Gershenzon, V. E., Gershenzon, E. M., Gol'tsman, G. N., Ptitsina, N. G., Tikhonov, V. V., et al. (1996). On the possibility of determining the microstructural parameters of an oil-bearing layer from radiophysical measurement data. J. of Communications Technology and Electronics, 41(5), 408–414.
Abstract: A method for the reconstruction of microstructural properties of an oil-bearing rock from the spectral dependence of the transmission factor of submillimeter waves is proposed.
|
Huebers, H. - W., Schubert, J., Semenov, A., Gol’tsman, G. N., Voronov, B. M., Gershenzon, E. M., et al. (1999). NbN phonon-cooled hot-electron bolometer as a mixer for THz heterodyne receivers. In J. M. Chamberlain (Ed.), Proc. SPIE (Vol. 3828, pp. 410–416). Spie.
Abstract: We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.
|
Lobanov, Y. V., Tong, C. -yu E., Hedden, A. S., Blundell, R., & Gol’tsman, G. N. (2010). Microwave-assisted measurement of the frequency response of terahertz HEB mixers with a Fourier transform spectrometer. In Proc. 21th Int. Symp. Space Terahertz Technol. (pp. 420–423).
Abstract: We describe a novel method of operation of the HEB direct detector for use with a Fourier Transform Spectrometer. Instead of elevating the bath temperature, we have measured the RF response of waveguide HEB mixers by applying microwave radiation to select appropriate bias conditions. In our experiment, a microwave signal is injected into the HEB mixer via its IF port. By choosing an appropriate injection level, the device can be operated close to the desired operating point. Furthermore, we have shown that both thermal biasing and microwave injection can reproduce the same spectral response of the HEB mixer. However, with the use of microwave injection, there is no need to wait for the mixer to reach thermal equilibrium, so characterisation can be done in less time. Also, the liquid helium consumption for our wet cryostat is also reduced. We have demonstrated that the signal- to-noise ratio of the FTS measurements can be improved with microwave injection.
|