Semenov, A., Hübers, H. - W., Engel, A., & Gol'tsman, G. N. (2002). Background limited superconducting quantum detector for astronomy. In NASA/ADS.
Abstract: We present the concept of the superconducting quantum detector for astronomy. Response to a single absorbed photon appears due to successive formation of a normal spot and phase-slip-centers in a narrow strip carrying sub-critical supercurrent. The detector simultaneously has a moderate energy resolution and a variable cut-off wavelength depending on both the material used and operation conditions. We simulated performance of the background-limited direct detector having the 100- micrometer cut-off wavelength. Low dark count rate will allow to realize 10-21 W Hz-1/2 noise equivalent power at 4 K background radiation. The intrinsic recovery time of the counter is rather determined by diffusion of nonequilibrium electrons, thus, thermal fluctuations do not hamper energy resolution of the detector. Provided an appropriate readout technique, the resolution should be better than 1/20 at 50- micrometer wavelength. Planar layout and relatively simple technology favor integration of the detector into an array.
|
|
|
Matyushkin, Y., Fedorov, G., Moskotin, M., Danilov, S., Ganichev, S., & Goltsman, G. (2020). Gate-mediated helicity sensitive detectors of terahertz radiation with graphene-based field effect transistors. In Graphene and 2dm Virt. Conf..
Abstract: Closing of the so-called terahertz gap results in an increased demand for optoelectronic devices operating in the frequency range from 0.1 to 10 THz. Active plasmonic in field effect devices based on high-mobility two-dimensional electron gas (2DEG) opens up opportunities for creation of on-chip spectrum [1] and polarization [2] analysers. Here we show that single layer graphene (SLG) grown using CVD method can be used for an all-electric helicity sensitive polarization broad analyser of THz radiation. Allourresults show plasmonic nature of response. Devices are made in a configuration ofa field-effect transistor (FET) with a graphene channel that has a length of 2 mkm and a width of 5.5 mkm. Response of opposite polarity to clockwise and anticlockwise polarized radiation is due to special antenna design (see Fig.1c) as follow works [2,3]. Our approaches can be extrapolated to other 2D materials and used as a tool to characterize plasmonic excitations in them. [1]Bandurin, D. A., etal.,Nature Communications, 9(1),(2018),1-8.[2]Drexler, C.,etal.,Journal of Applied Physics, 111(12),(2012),124504.[3]Gorbenko, I. V.,et al.,physica status solidi (RRL)–Rapid Research Letters, 13(3),(2019),1800464.
|
|
|
Pentin, I., Finkel, M., Maslennikov, S., Vakhtomin, Y., Smirnov, K., Kaurova, N., et al. (2017). Superconducting hot-electron-bolometer mixers for the mid-IR. Rus. J. Radio Electron., (10), http://jre.cplire.ru/jre/oct17/9/text.pdf. Retrieved September 20, 2024, from http://jre.cplire.ru/jre/oct17/9/abstract_e.html
Abstract: The work presents the result of development of the NbN superconducting hot-electron-bolometer (HEB) mixer. The sensitive element of the mixer is directly coupled to mid-IR radiation, and doesn’t have planar metallic antenna. Investigations of noise characteristics of NbN HEB mixer were performed at the frequency 28.4 THz (λ = 10.6 µm) by using gas-discharge CW CO2-laser without consideration of optical and electrical losses in the heterodyne receiver. The noise temperature of NbN HEB mixer with the size of the sensitive element 10 µm × 10 µm was 2320 K (~ 1.5hν/kB) at the heterodyne frequency of 28.4 THz. The noise temperature was determined by measuring the Y-factor taking into account the term which describes fluctuations of zero-point oscillations in accordance with the fluctuation-dissipation theorem of Calle-Welton. Isothermal method was used to estimate the absorbed heterodyne radiation power which was 9 µW at the optimal operating point for the minimum noise temperature of NbN HEB mixer.
|
|
|
Averkin, A. S., Shishkin, A. G., Chichkov, V. I., Voronov, B. M., Goltsman, G. N., Karpov, A., et al. (2014). Tunable frequency-selective surface based on superconducting split-ring resonators. In 8th Metamaterials.
Abstract: We study a possibility to use the 2D superconducting metamaterial as a tunable frequency-selective surface (FSS). The proposed FSS is made of sub-wavelength size (l/14) metamaterial unit cells, where a split-ring resonator is embedded in a small iris aperture in a metal plane. The split-ring resonator is made of NbN film, and its resonance frequency is tuned by the temperature of the sample, changing the kinetic inductance of NbN film. The Ansoft HFSS simulation predicts the FSS tuning range of about 10-20 %. The developed superconducting FSS may be used as a tunable band-pass filter or modulator.
|
|
|
Verevkin, A., Zhang, J., Pearlman, A., Slysz, W., Sobolewski, R., Korneev, A., et al. (2004). Ultimate sensitivity of superconducting single-photon detectors in the visible to infrared range.
Abstract: We present our quantum efficiency (QE) and noise equivalent power (NEP) measurements of the meandertype ultrathin NbN superconducting single-photon detector in the visible to infrared radiation range. The nanostructured devices with 3.5-nm film thickness demonstrate QE up to~ 10% at 1.3–1.55 µm wavelength, and up to 20% in the entire visible range. The detectors are sensitive to infrared radiation with the wavelengths down to~ 10 µm. NEP of about 2× 10-18 W/Hz1/2 was obtained at 1.3 µm wavelength. Such high sensitivity together with GHz-range counting speed, make NbN photon counters very promising for efficient, ultrafast quantum communications and another applications. We discuss the origin of dark counts in our devices and their ultimate sensitivity in terms of the resistive fluctuations in our superconducting nanostructured devices.
|
|