Mohan, N., Minaeva, O., Gol'tsman, G. N., Nasr, M. B., Saleh, B. E., Sergienko, A. V., et al. (2008). Photon-counting optical coherence-domain reflectometry using superconducting single-photon detectors. Opt. Express, 16(22), 18118–18130.
Abstract: We consider the use of single-photon counting detectors in coherence-domain imaging. Detectors operated in this mode exhibit reduced noise, which leads to increased sensitivity for weak light sources and weakly reflecting samples. In particular, we experimentally demonstrate the possibility of using superconducting single-photon detectors (SSPDs) for optical coherence-domain reflectometry (OCDR). These detectors are sensitive over the full spectral range that is useful for carrying out such imaging in biological samples. With counting rates as high as 100 MHz, SSPDs also offer a high rate of data acquisition if the light flux is sufficient.
|
Nasr, M. B., Minaeva, O., Goltsman, G. N., Sergienko, A. V., Saleh, B. E., & Teich, M. C. (2008). Submicron axial resolution in an ultrabroadband two-photon interferometer using superconducting single-photon detectors. Opt. Express, 16(19), 15104–15108.
Abstract: We generate ultrabroadband biphotons via the process of spontaneous parametric down-conversion in a quasi-phase-matched nonlinear grating that has a linearly chirped poling period. Using these biphotons in conjunction with superconducting single-photon detectors (SSPDs), we measure the narrowest Hong-Ou-Mandel dip to date in a two-photon interferometer, having a full width at half maximum (FWHM) of approximately 5.7 fsec. This FWHM corresponds to a quantum optical coherence tomography (QOCT) axial resolution of 0.85 µm. Our results indicate that a high flux of nonoverlapping biphotons may be generated, as required in many applications of nonclassical light.
|
Stucki, D., Barreiro, C., Fasel, S., Gautier, J. - D., Gay, O., Gisin, N., et al. (2009). Continuous high speed coherent one-way quantum key distribution. Opt. Express, 17(16), 13326–13334.
Abstract: Quantum key distribution (QKD) is the first commercial quantum technology operating at the level of single quanta and is a leading light for quantum-enabled photonic technologies. However, controlling these quantum optical systems in real world environments presents significant challenges. For the first time, we have brought together three key concepts for future QKD systems: a simple high-speed protocol; high performance detection; and integration both, at the component level and for standard fibre network connectivity. The QKD system is capable of continuous and autonomous operation, generating secret keys in real time. Laboratory and field tests were performed and comparisons made with robust InGaAs avalanche photodiodes and superconducting detectors. We report the first real world implementation of a fully functional QKD system over a 43dB-loss (150km) transmission line in the Swisscom fibre optic network where we obtained average real-time distribution rates over 3 hours of 2.5bps.
|
Anant, V., Kerman, A. J., Dauler, E. A., Yang, J. K. W., Rosfjord, Kine M., & Berggren, K. K. (2008). Optical properties of superconducting nanowire single-photon detectors. Opt. Express, 16(14), 10750.
|
Miller, A. J., Lita, A. E., Calkins, B., Vayshenker, I., Gruber, S. M., & Nam, S. W. (2011). Compact cryogenic self-aligning fiber-to-detector coupling with losses below one percent. Opt. Express, 19(10), 9102–9110.
Abstract: We present a compact packaging technique for coupling light from a single-mode telecommunication fiber to cryogenic single-photon sensitive devices. Our single-photon detectors are superconducting transition-edge sensors (TESs) with a collection area only a factor of a few larger than the area of the fiber core which presents significant challenges to low-loss fiber-to-detector coupling. The coupling method presented here has low loss, cryogenic compatibility, easy and reproducible assembly and low component cost. The system efficiency of the packaged single-photon counting detectors is verified by the “triplet method†of power-source calibration along with the “multiple attenuator†method that produces a calibrated single-photon flux. These calibration techniques, when used in combination with through-wafer imaging and fiber back-reflection measurements, give us confidence that we have achieved coupling losses below 1 % for all devices packaged according to the self-alignment method presented in this paper.
|