|
Fedorov, G., Kardakova, A., Gayduchenko, I., Voronov, B. M., Finkel, M., Klapwijk, T. M., et al. (2014). Photothermoelectric response in asymmetric carbon nanotube devices exposed to sub-THz radiation. In Proc. 25th Int. Symp. Space Terahertz Technol. (71).
Abstract: This work reports on the voltage response of asymmetric carbon nanotube devices to sub-THz radiation at the frequency of 140 GHz. The devices contain CNT’s, which are over their length partially suspended and partially Van der Waals bonded to a SiO 2 substrate, causing a difference in thermal contact. Different heat sinking of CNTs by source and drain gives rise to temperature gradient and consequent thermoelectric power (TEP) as such a device is exposed to the sub-THz radiation. Sign of the DC signal, its power and gate voltage dependence observed at room temperature are consistent with this scenario. At liquid helium temperature the observed response is more complex. DC voltage signal of an opposite sign is observed in a narrow range of gate voltages at low temperatures and under low radiation power. We argue that this may indicate a true photovoltaic response from small gap (less than 10meV) CNT’s, an effect never reported before. While it is not clear if the observed effects can be used to develop efficient THz detectors we note that the responsivity of our devices exceeds that of CNT based devices in microwave or THz range reported before at room temperature. Besides at 4.2 K notable increase of the sample conductance (at least four-fold) is observed. Our recent results with asymmetric carbon nanotube devices response to THz radiation (2.5 THz) will also be presented.
|
|
|
Ожегов, Р. В., Горшков, К. Н., Окунев, О. В., & Гольцман, Г. Н. (2010). Сверхпроводниковый смеситель на эффекте электронного разогрева как элемент матрицы системы построения тепловых изображений. Письма в ЖТФ, 36(21), 70–78.
Abstract: Исследована возможность использования матрицы чувствительных элементов на гиперполусферической линзе диаметром 12 mm в тепловизоре терагерцевого диапазона частот. Получены размеры области на линзе, приемлемой для расположения матрицы, в которой шумовая температура приемника меняется в пределах 16% от средней. Диаметр этой области составил 3.3% диаметра линзы.Получены отклонения основного лепестка диаграммы направленности, которые составили ±1.25â—<a6> от направления с оптимальным положением смесителя. Флуктуационная чувствительность приемника в эксперименте составила 0.5 K на частоте 300 GHz.
|
|
|
Korneev, A., Finkel, M., Maslennikov, S., Korneeva, Y., Florya, I., Tarkhov, M., et al. (2010). Superconducting NbN terahertz detectors and infrared photon counters. Вестник НГУ. Серия: физ., 5(4), 68–72.
Abstract: We present our recent achievements in the development of sensitive and ultrafast thin-film superconducting sensors: hot-electron bolometers (HEB), HEB-mixers for terahertz range and infrared single-photon counters. These sensors have already demonstrated a performance that makes them devices-of-choice for many terahertz and optical applications. Keywords: Hot electron bolometer mixers, infrared single-photon detectors, superconducting device fabrication, superconducting NbN films.
|
|
|
Karasik, B. S., Lindgren, M., Zorin, M. A., Danerud, M., Winkler, D., Trifonov, V. V., et al. (1994). Picosecond detection and broadband mixing of near-infrared radiation by YBaCuO films. In M. Nahum, & J. - C. Villegier (Eds.), Proc. SPIE (Vol. 2159, pp. 68–76). Spie.
Abstract: Nonequilibrium picosecond and bolometric responses of YBCO films 500 angstroms thick patterned into 20 X 20 micrometers 2 size structure to 17 ps laser pulses and modulated radiation of GaAs and CO2 lasers have been studied. The modulation frequencies up to 10 GHz for GaAs laser and up to 1 GHz for CO2 were attained. The use of small radiation power (1 – 10 mW/cm2 for cw radiation and 10 – 100 nJ/cm2 for pulse radiation) in combination with high sensitive read-out system made possible to avoid any non-linear transient processes caused by an overheating of sample above a critical temperature or S-N switching enhanced by an intense radiation. Responses due to the change of kinetic inductance were believed to be negligible. The only signals observed were caused by a small change of the film resistance either in the resistive state created by a bias current or in the normal state. The data obtained by means of pulse and modulation techniques are in agreement. The responsivity about 1 V/W was measured at 1 GHz modulation frequency both for 0.85 micrometers and 10.6 micrometers wavelengths. The sensitivity of high-Tc fast wideband infrared detector is discussed.
|
|
|
Neroev, V. V., Iomdina, E. N., Khandzhyan, A. T., Khodzhabekyan, N. V., Sengaeva, M. D., Ivanova, A. V., et al. (2021). Experimental study of the effect of corneal hydration and its biomechanical properties on the results of photorefractive keratectomy. Vestn. Oftalmol., 137(3), 68–75.
Abstract: Water content in the cornea may affect the outcome of its excimer laser ablation, especially in presbyopic patients with myopic refraction. This hypothesis can be tested by scanning the cornea in the terahertz (THz) range to determine its hydration level.
Purpose: To study the effect of hydration of the cornea determined by non-contact THz scanning and its biomechanical parameters on the results of photorefractive keratectomy (PRK) in an experiment.
Material and methods: PRK was performed using the Nidek EC-5000 QUEST excimer laser on 8 rabbit eyes. Corneal hydration was evaluated by determining the reflection coefficient (RC) in the THz electromagnetic radiation range before PRK, after 3-5 days, and after 1, 2, 3, and 4 months. Clinical examination included autorefractometry, assessment of corneal thickness and other anatomical and optical parameters of the anterior eye segment (Galilei G6, Ziemer Ophthalmic Systems AG 6.0.2, Switzerland), measurement of corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (ORA; Reichert, USA), as well as tear production (Schirmer test).
Results: The initial water content in the cornea has a significant effect on the thickness of the removed layer, i.e. on the PRK effect, with correlation coefficient of Rs= -0.976 (p<0.01). The correlation between CH and the ablation depth is less pronounced (Rs=0.643), and CRF had no correlation with it (Rs= -0.089). Biomechanical indicators of the cornea depend on its hydration: changes in CH and CRF after excimer laser ablation qualitatively coincide with changes in RC, the correlation coefficient between RC and the initial value of CH is R= -0.619 (moderate negative correlation).
Conclusion: THz scanning is an effective non-contact technology for monitoring corneal hydration level. The mismatch of the hypoeffect of keratorefractive excimer laser intervention planned for patients with presbyopia with the actual outcome can be caused by individual decrease in the initial water content in the cornea.
|
|
|
Гольцман, Г. Н., Разумовская, И. В., Окунев, О. В., Чулкова, Г. М., Корнеев, А. А., Финкель, М. И., et al. (2011). Сборник программ учебных дисциплин профессионального цикла подготовки магистров и бакалавров по направлению «Физика». Прометей, , 67.
|
|
|
Meledin, D., Tong, C. Y. - E., Blundell, R., Kaurova, N., Smirnov, K., Voronov, B., et al. (2002). The sensitivity and IF bandwidth of waveguide NbN hot electron bolometer mixers on MgO buffer layers over crystalline quartz. In Harvard university (Ed.), Proc. 13th Int. Symp. Space Terahertz Technol. (pp. 65–72). Cambridge, MA, USA.
Abstract: We have developed and characterized waveguide phonon-cooled NbN Hot Electron Bolometer (FMB) mixers fabricated from a 3-4 nm thick NbN film deposited on a 200nm thick MgO buffer layer over crystalline quartz. Double side band receiver noise temperatures of 900-1050 K at 1.035 THz, and 1300-1400 K at 1.26 THz have been measured at an intermediate frequency of 1.5 GHz. The intermediate frequency bandwidth, measured at 0.8 THz LO frequency, is 3.2 GHz at the optimal bias point for low noise receiver operation.
|
|
|
Gershenzon, E. M., & Gol'tsman, G. N. (1971). Transitions of electrons between excited states of donors in germanium. JETP Lett., 14(2), 63–65.
|
|
|
Ryabchun, S. A., Tretyakov, I. V., Finkel, M. I., Maslennikov, S. N., Kaurova, N. S., Seleznev, V. A., et al. (2008). Fabrication and characterisation of NbN HEB mixers with in situ gold contacts. In Proc. 19th Int. Symp. Space Terahertz Technol. (pp. 62–67). Groningen, Netherlands.
Abstract: We present our recent results of the fabrication and testing of NbN hot-electron bolometer mixers with in situ gold contacts. An intermediate frequency bandwidth of about 6 GHz has been measured for the mixers made of a 3.5-nm NbN film on a plane Si substrate with in situ gold contacts, compared to 3.5 GHz for devices made of the same film with ex situ gold contacts. The increase in the intermediate frequency bandwidth is attributed to additional diffusion cooling through the improved contacts, which is further supported by the its dependence on the bridge length: intermediate frequency bandwidths of 3.5 GHz and 6 GHz have been measured for devices with lengths of 0.35 μm and 0.16 μm respectively at a local oscillator frequency of 300 GHz near the superconducting transition. At a local oscillator frequency of 2.5 THz the receiver has offered a DSB noise temperature of 950 K. When compared to the previous result of 1300 K obtained at the same local oscillator frequency for devices fabricated with an ex situ route, such a low value of the noise temperature may also be attributed to the improved gold contacts.
|
|
|
Золотов, Ф. И., Дивочий, А. В., Вахтомин, Ю. Б., Пентин, И. В., Морозов, П. В., Селезнев, В. А., et al. (2018). Применение тонких сверхпроводниковых пленок нитрида ванадия для изготовления счетчиков одиночных ИК-фотонов. In Сборн. науч. труд. VII международн. конф. по фотонике и информац. опт. (pp. 60–61).
Abstract: Получены первые результаты по применению сверхпроводниковых пленок нитрида ванадия (VN) для детекторов одиночных фотонов ИК-диапазона. Изучение сверхпроводниковых однофотонных детекторов (SSPD), изготовленных на основе ультратонких (~5 нм) пленок VN, показало возможность создания устройств с близкой к насыщению зависимостью квантовой эффективности от тока смещения детекторов в телекоммуникационном диапазоне длин волн. Также нами были исследованы кинетическая индуктивность изготовленных структур с различной длиной сверхпроводниковой полоски и времена релаксации электронов в тонких сверхпроводниковых пленках VN.
|
|