Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1975). Cyclotron resonance of electrons in Ge in a quantizing magnetic field in the case of inelastic scattering by acoustic phonons. Sov. Phys. JETP, 40(2), 311–315.
Abstract: Results are presented of an experimental study of the linewidth of cyclotron resonance under strong quantization conditions on the scattering of electrons by acoustic phonons. The measurements were performed in the 2....{).4 mm wavelength range at temperatures between 10 and 1.4 OK. A number of singularities were observed in the temperature and frequency dependences of the cyclotron linewidth. These can be ascribed to the effect of inhomogeneous broadening due to nonparabolicity of the electron spectrum, which is renormalized as a result of interaction with acoustic phonons.
|
Gershenzon, E. M., Gol'tsman, G. N., & Ptitsina, N. G. (1973). Submillimeter spectroscopy of semiconductors. Sov. Phys. JETP, 37(2), 299–304.
Abstract: The possibility is considered of carrying out submillimeter-wave spectral investigations of semiconductors by means of a high resolution spectrometer with backward-wave tubes. Results of a study of the excitation spectra of small impurities, D-(A +) centers and free excitons in germanium are presented.
|
Gershenzon, E. M., Gershenzon, M. E., Gol'tsman, G. N., Semenov, A. D., & Sergeev, A. V. (1982). Nonselective effect of electromagnetic radiation on a superconducting film in the resistive state. JETP Lett., 36(7), 296–299.
|
Merkel, H. F., Yagoubov, P. A., Kroug, M., Khosropanah, P., Kollberg, E. L., Gol’tsman, G. N., et al. (1998). Noise temperature and absorbed LO power measurement methods for NbN phonon-cooled hot electron bolometric mixers at terahertz frequencies. In Proc. 28th European Microwave Conf. (Vol. 1, pp. 294–299).
Abstract: In this paper the absorbed LO power requirements and the noise performance of NbN based phonon-cooled hot electron bolometric (HEB) quasioptical mixers are investigated for RF frequencies in the 0.55-1.1 range The minimal measured DSB noise temperatures are about 500 K at 640 GHz, 600 K at 750 GHz, 850 K at 910 GHz and 1250 K at 1.1 THz. The increase in noise temperature at 1.1THz is attributed to water absorption. The absorbed LO power is measured using a calorimetric approach. The results are subsequently corrected for lattice heating. These values are compared to results of a novel one dimensional hot spot mixer models and to a more traditional isotherm method which tends to underestimate the absorbed LO power for small bias powers. Typically a LO power between 50nW and 100nW is needed to pump the device to the optimal operating point.
|
Hübers, H. - W., Semenov, A. D., Richter, H., Schubert, J., Hadjiloucas, S., Bowen, J. W., et al. (2001). Antenna pattern of the quasi-optical hot-electron bolometric mixer at terahertz frequencies. In Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 286–296). San Diego, CA, USA.
|