|
Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1975). Cyclotron resonance of electrons in Ge in a quantizing magnetic field in the case of inelastic scattering by acoustic phonons. Sov. Phys. JETP, 40(2), 311–315.
Abstract: Results are presented of an experimental study of the linewidth of cyclotron resonance under strong quantization conditions on the scattering of electrons by acoustic phonons. The measurements were performed in the 2....{).4 mm wavelength range at temperatures between 10 and 1.4 OK. A number of singularities were observed in the temperature and frequency dependences of the cyclotron linewidth. These can be ascribed to the effect of inhomogeneous broadening due to nonparabolicity of the electron spectrum, which is renormalized as a result of interaction with acoustic phonons.
|
|
|
Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1976). Scattering of electrons by charged impurities in Ge under cyclotron resonance conditions. Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников, 10, 1379–1383.
|
|
|
Gershenzon, E. M., Orlov, L. A., & Ptitsina, N. G. (1975). Absorption spectra in electron transitions between excited states of impurities in germanium. JETP Lett., 22(4), 95–97.
|
|
|
Bondarenko, O. I., Gershenzon, E. M., Gurvich, Y. A., Orlova, S. L., & Ptitsina, N. G. (1972). Measurement of the width of the cyclotron resonance line of n-type Ge in quantizing magnetic fields. Presumably: Sov. Phys. Semicond. | Физика и техника полупроводников, 6, 362–363.
|
|
|
Blundell, R., Kawamura, J. H., Tong, C. E., Papa, D. C., Hunter, T. R., Gol’tsman, G. N., et al. (1998). A hot-electron bolometer mixer receiver for the 680-830 GHz frequency range. In Proc. 6-th Int. Conf. Terahertz Electron. (pp. 18–20). IEEE.
Abstract: We describe a heterodyne receiver designed to operate in the partially transparent atmospheric windows centered on 680 and 830 GHz. The receiver incorporates a niobium nitride thin film, cooled to 4.2 K, as the phonon-cooled hot-electron mixer element. The double sideband receiver noise, measured over the frequency range 680-830 GHz, is typically 700-1300 K. The instantaneous output bandwidth of the receiver is 600 MHz. This receiver has recently been used at the SubMillimeter Telescope, jointly operated by the Steward Observatory and the Max Planck Institute for Radioastronomy, for observations of the neutral carbon and CO spectral lines at 810 GHz and at 806 and 691 GHz respectively. Laboratory measurements on a second mixer in the same test receiver have yielded extended high frequency performance to 1 THz.
|
|