Kooi, J. W. (2008). Advanced receivers for submillimeter and far infrared astronomy. Doctoral thesis, , .
Keywords: HEB, SIS, TES, NEP, noise temperature, IF bandwidth, waveguide, impedance, conversion gain, FTS, integrated array, stability, Allan variance, multi-layer antireflection coating
|
Tretyakov, I., Shurakov, A., Perepelitsa, A., Kaurova, N., Svyatodukh, S., Zilberley, T., et al. (2019). Silicon room temperature IR detectors coated with Ag2S quantum dots. In Proc. IWQO (pp. 369–371).
Abstract: For decades silicon has been the chief technological semiconducting material of modern microelectronics. Application of silicon detectors in optoelectronic devices are limited to the visible and near infrared ranges, due to their transparency for radiation with a wavelength higher than 1.1 μm. The expansion Si absorption towards longer wave lengths is a considerable interest to optoelectronic applications. In this work we present an elegant and effective solution to this problem using Ag2S quantum dots, creating impurity states in Si to cause sub-band gap photon absorption. The sensitivity of room temperature zero-bias Si_Ag2S detectors, which we obtained is 1011 cmHzW . Given the variety of QDs parameters such as: material, dimensions, our results open a path towards the future study and development of Si detectors for technological applications.
|
Stellari, F., & Song, P. (2005). Testing of ultra low voltage CMOS microprocessors using the superconducting single-photon detector (SSPD). In Proc. 12th IPFA (2). IEEE.
Abstract: In F. Stellari and P. Song (2004) the authors have shown a comparison among different detectors used for diagnosing integrated circuits (ICs) by means of the PICA method. In their experiments they used two versions of the SSPD detector (p-SSPD is a prototype version, while c-SSPD is the first commercially available generation of the detector as presented in W. K. Lo et al. (2002), as well as the imaging detector (S-25 photo-multiplier tube (PMT) as discussed in W. G. McMullan (1987)) used in the conventional PICA technique. A microprocessor chip fabricated in a 0.13 μm 1.2 V technology is used to show that c-SSPD provides a significant reduction in acquisition time for the collection of optical waveforms from chips running at very low. In this paper, the authors summarize the main results.
|
Prober, D. E. (1993). Superconducting terahertz mixer using a transition-edge microbolometer. Appl. Phys. Lett., 62(17), 2119–2121.
|
Miller, A. J., Lita, A. E., Calkins, B., Vayshenker, I., Gruber, S. M., & Nam, S. W. (2011). Compact cryogenic self-aligning fiber-to-detector coupling with losses below one percent. Opt. Express, 19(10), 9102–9110.
Abstract: We present a compact packaging technique for coupling light from a single-mode telecommunication fiber to cryogenic single-photon sensitive devices. Our single-photon detectors are superconducting transition-edge sensors (TESs) with a collection area only a factor of a few larger than the area of the fiber core which presents significant challenges to low-loss fiber-to-detector coupling. The coupling method presented here has low loss, cryogenic compatibility, easy and reproducible assembly and low component cost. The system efficiency of the packaged single-photon counting detectors is verified by the “triplet method†of power-source calibration along with the “multiple attenuator†method that produces a calibrated single-photon flux. These calibration techniques, when used in combination with through-wafer imaging and fiber back-reflection measurements, give us confidence that we have achieved coupling losses below 1 % for all devices packaged according to the self-alignment method presented in this paper.
|