Gol'tsman, G., Semenov, A., Smirnov, K., & Voronov, B. (2001). Background limited quantum superconducting detector for submillimeter wavelengths. In Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 469–475).
|
Hübers, H. - W., Semenov, A., Schubert, J., Gol'tsman, G., Voronov, B., & Gershenzon, E. (2000). Performance of the phonon-cooled hot-electron bolometric mixer between 0.7 THz and 5.2 THz. In Proc. 8-th Int. Conf. on Terahertz Electronics (pp. 117–119).
Abstract: We report on the phonon cooled NbN hot electron bolometer as mixer in the terahertz frequency range. Its hybrid antenna consists of a hyperhemispheric silicon lens and a logarithmic-spiral feed antenna. Noise temperatures have been measured between 0.7 THz and 5.2 THz. A quarter wavelength layer of Parylene works as antireflection coating for the silicon lens and reduces the noise temperature by about 30. It was found that the antenna pattern at 2.5 THz is determined by the feed antenna and not by the diameter of the lens.
|
Semenov, A. D., Gol'tsman, G. N., & Sobolewski, R. (2002). Hot-electron effect in superconductors and its applications for radiation sensors. Supercond. Sci. Technol., 15(4), R1–R16.
Abstract: The paper reviews the main aspects of nonequilibrium hot-electron phenomena in superconductors and various theoretical models developed to describe the hot-electron effect. We discuss implementation of the hot-electron avalanche mechanism in superconducting radiation sensors and present the most successful practical devices, such as terahertz mixers and direct intensity detectors, for far-infrared radiation. Our presentation also includes the novel approach to hot-electron quantum detection implemented in superconducting x-ray to optical photon counters.
|
Ryabchun, S., Tong, C. - Y. E., Blundell, R., & Gol'tsman, G. (2009). Stabilization scheme for hot-electron bolometer receivers using microwave radiation. IEEE Trans. Appl. Supercond., 19(1), 14–19.
Abstract: We present the results of a stabilization scheme for terahertz receivers based on NbN hot-electron bolometer (HEB) mixers that uses microwave radiation with a frequency much lower than the gap frequency of NbN to compensate for mixer current fluctuations. A feedback control loop, which actively controls the power level of the injected microwave radiation, has successfully been implemented to stabilize the operating point of the HEB mixer. This allows us to increase the receiver Allan time to 10 s and also improve the temperature resolution of the receiver by about 30% in the total power mode of operation.
|
Korneev, A., Vachtomin, Y., Minaeva, O., Divochiy, A., Smirnov, K., Okunev, O., et al. (2007). Single-photon detection system for quantum optics applications. IEEE J. Select. Topics Quantum Electron., 13(4), 944–951.
Abstract: We describe the design and characterization of a fiber-coupled double-channel single-photon detection system based on superconducting single-photon detectors (SSPD), and its application for quantum optics experiments on semiconductor nanostructures. When operated at 2-K temperature, the system shows 10% quantum efficiency at 1.3-¿m wavelength with dark count rate below 10 counts per second and timing resolution <100 ps. The short recovery time and absence of afterpulsing leads to counting frequencies as high as 40 MHz. Moreover, the low dark count rate allows operation in continuous mode (without gating). These characteristics are very attractive-as compared to InGaAs avalanche photodiodes-for quantum optics experiments at telecommunication wavelengths. We demonstrate the use of the system in time-correlated fluorescence spectroscopy of quantum wells and in the measurement of the intensity correlation function of light emitted by semiconductor quantum dots at 1300 nm.
|