Kroug, M., Cherednichenko, S., Choumas, M., Merkel, H., Kollberg, E., Hübers, H. - W., et al. (2001). HEB quasi-optical heterodyne receiver for THz frequencies. In Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 244–252). San Diego, CA, USA.
|
|
|
Maslennikov, S., Antipov, S., Shishkov, A., Svechnikov, S., Voronov, B., Smirnov, K., et al. (2002). NbN HEB mixer noise temperature measurements with hot/cold load mounted inside the helium cryostat at 300 GHz. In Proc. Int. Student Seminar on Microwave Appl. of Novel Physical Phenomena supported by IEEE. St.-Petersburg: LETI.
|
|
|
Hübers, H. - W., Semenov, A. D., Richter, H., Schubert, J., Hadjiloucas, S., Bowen, J. W., et al. (2001). Antenna pattern of the quasi-optical hot-electron bolometric mixer at terahertz frequencies. In Proc. 12th Int. Symp. Space Terahertz Technol. (pp. 286–296). San Diego, CA, USA.
|
|
|
Ferrari, S., Kovalyuk, V., Hartmann, W., Vetter, A., Kahl, O., Lee, C., et al. (2017). Hot-spot relaxation time current dependence in niobium nitride waveguide-integrated superconducting nanowire single-photon detectors. Opt. Express, 25(8), 8739–8750.
Abstract: We investigate how the bias current affects the hot-spot relaxation dynamics in niobium nitride. We use for this purpose a near-infrared pump-probe technique on a waveguide-integrated superconducting nanowire single-photon detector driven in the two-photon regime. We observe a strong increase in the picosecond relaxation time for higher bias currents. A minimum relaxation time of (22 +/- 1)ps is obtained when applying a bias current of 50% of the switching current at 1.7 K bath temperature. We also propose a practical approach to accurately estimate the photon detection regimes based on the reconstruction of the measured detector tomography at different bias currents and for different illumination conditions.
|
|
|
Meledin, D., Tong, C. Y. - E., Blundell, R., Kaurova, N., Smirnov, K., Voronov, B., et al. (2002). The sensitivity and IF bandwidth of waveguide NbN hot electron bolometer mixers on MgO buffer layers over crystalline quartz. In Harvard university (Ed.), Proc. 13th Int. Symp. Space Terahertz Technol. (pp. 65–72). Cambridge, MA, USA.
Abstract: We have developed and characterized waveguide phonon-cooled NbN Hot Electron Bolometer (FMB) mixers fabricated from a 3-4 nm thick NbN film deposited on a 200nm thick MgO buffer layer over crystalline quartz. Double side band receiver noise temperatures of 900-1050 K at 1.035 THz, and 1300-1400 K at 1.26 THz have been measured at an intermediate frequency of 1.5 GHz. The intermediate frequency bandwidth, measured at 0.8 THz LO frequency, is 3.2 GHz at the optimal bias point for low noise receiver operation.
|
|