toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Ожегов, Р.В.; Окунев, О.В.; Гольцман, Г.Н. openurl 
  Title Флуктуационная чувствительность сверхпроводящего болометрического смесителя на эффекте разогрева электронного газа Type Journal Article
  Year 2009 Publication Радиотехника Abbreviated Journal  
  Volume Issue 3 Pages 120-124  
  Keywords смеситель на горячих электронах; флуктуационная чувствительность; тепловизор терагерцевого диапазона частот; hot-electron bolometer mixer; Imaging system; Noise equivalent temperature difference; Heterodyne receiver; Terahertz range  
  Abstract Interest in research in the terahertz range is driven by a great number of various applications, where terahertz instruments may play a leading role. To name just a few, such applications include study of the cosmic microwave background radiation and the distribution of the dark matter, medicine, navigation, fire alarm, security systems and environmental monitoring. The paper discusses the possibility of using a receiver based on the hot-electron effect in superconducting films as an imaging system. We present the results of the noise equivalent temperature difference (NETD) measurements performed with a hot-electron bolometer mixer made from a thin superconducting film. The receiver with a noise temperature of ~ 3800 K at a local oscillator frequency of 300 GHz a bandwidth of 500 MHz and an integration time of 1 s has offered an NETD of 0.5 K. We have also developed a technique that enabled us to reduce the contribution of the mixer gain fluctuations to the overall system instability. As of this writing, the above value of the NETD is the lowest value offered for this type of receiver, which indicates the possibility to use such receivers in real-time imaging systems. The technique offered in the paper for achieving the limiting value of the NETD offers an alternative to the phase-locking scheme.

Представены результаты измерения флуктуационной чувствительности (NETD – noise equivalent temperature difference) болометрического смесителя на эффекте разогрева электронного газа в тонких сверхпроводящих пленках. Получено предельное значение NETD, равное 0,5 К, при шумовой температуре приемника 3800 К, ширине полосы преобразования 500 МГц, постоянной времени 1 с и частоте гетеродина 300 ГГц. Разработана методика достижения предельной флуктуационной чувствительности, позволяющая избежать влияния нестабильности коэффициента преобразования смесителя.
 
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 728  
Permanent link to this record
 

 
Author Lydersen, Lars; Wiechers, Carlos; Wittmann, Christoffer; Elser, Dominique; Skaar, Johannes; Makarov, Vadim openurl 
  Title Thermal blinding of gated detectors in quantum cryptography Type Journal Article
  Year 2010 Publication Optics Express Abbreviated Journal Opt. Express  
  Volume 18 Issue 26 Pages 27938-27954  
  Keywords quantum cryptography; QKD; hacking; SPD; APD  
  Abstract It has previously been shown that the gated detectors of two commercially available quantum key distribution (QKD) systems are blindable and controllable by an eavesdropper using continuous-wave illumination and short bright trigger pulses, manipulating voltages in the circuit [L. Lydersen et al., Nat. Photonics DOI:10.1038/nphoton.2010.214]. This allows for an attack eavesdropping the full raw and secret key without increasing the quantum bit error rate (QBER). Here we show how thermal effects in detectors under bright illumination can lead to the same outcome. We demonstrate that the detectors in a commercial QKD system Clavis2 can be blinded by heating the avalanche photo diodes (APDs) using bright illumination, so-called thermal blinding. Further, the detectors can be triggered using short bright pulses once they are blind. For systems with pauses between packet transmission such as the plug-and-play systems, thermal inertia enables Eve to apply the bright blinding illumination before eavesdropping, making her more difficult to catch.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 729  
Permanent link to this record
 

 
Author Wiechers, C.; Lydersen, L.; Wittmann, C.; Elser, D.; Skaar, J.; Marquardt, Ch; Makarov, V.; Leuchs, G. openurl 
  Title After-gate attack on a quantum cryptosystem Type Journal Article
  Year 2011 Publication New J. Phys. Abbreviated Journal  
  Volume 13 Issue 1 Pages 14  
  Keywords quantum cryptography; hacking; interception; attack; SPD; APD; QKD  
  Abstract We present a method to control the detection events in quantum key distribution systems that use gated single-photon detectors. We employ bright pulses as faked states, timed to arrive at the avalanche photodiodes outside the activation time. The attack can remain unnoticed, since the faked states do not increase the error rate per se. This allows for an intercept-resend attack, where an eavesdropper transfers her detection events to the legitimate receiver without causing any errors. As a side effect, afterpulses, originating from accumulated charge carriers in the detectors, increase the error rate. We have experimentally tested detectors of the system id3110 (Clavis2) from ID Quantique. We identify the parameter regime in which the attack is feasible despite the side effect. Furthermore, we outline how simple modifications in the implementation can make the device immune to this attack.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 730  
Permanent link to this record
 

 
Author Ожегов, Роман Викторович openurl 
  Title Флуктуационная чувствительность и стабильность приемников с СИС и HEB смесителями для терагерцового тепловидения Type Journal Article
  Year 2011 Publication Радиофизика Abbreviated Journal  
  Volume Issue Pages 135  
  Keywords HEB  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 731  
Permanent link to this record
 

 
Author Килин, С. Я. openurl 
  Title Квантовая информация Type Journal Article
  Year 1999 Publication Успехи физических наук Abbreviated Journal УФН  
  Volume 169 Issue 5 Pages 507-527  
  Keywords quantum cryptography; QKD, BB84  
  Abstract Новое направление физики – квантовая информация – возникло на стыке квантовой механики, оптики, теории относительности и программирования, дискретной математики, лазерной физики и спектроскопии и включает в себя вопросы квантовых вычислений, квантовых компьютеров, квантовой телепортации и квантовой криптографии, проблемы декогеренции и спектроскопии одиночных молекул и примесных центров. Сообщается о некоторых новых результатах в этой быстро развивающейся области исследований.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN (up) ISBN Medium  
  Area Expedition Conference  
  Notes Approved no  
  Call Number RPLAB @ gujma @ Serial 732  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: