Tiulina, V., Iomdina, E., Goltsman, G., Seliverstov, S., Sianosyan, A., Teplyakova, K., et al. (2019). UVB promotes the initiation of uveitic inflammatory and changes in thehydration of the cornea in vivo (Vol. 9).
Abstract: Recently, active research has been conducted in the field of terahertz (THz) scanning of human tissues for noninvasive determination of their hydration level, which haves hown high diagnostic efficiency of this technology in various pathological conditions. Recently, we have developed a laboratory model of the facility for monitoring the state of the water balance of the cornea using THz scanning in vivo, which opens up the possibility of applying this approach in ophthalmology. The aim of the work wasto compare the results of the THz scan of the cornea with its clinical changes using the example of an experimental model of the UV induced keratouveitis. Anexperimental study, which included a comprehensive assessment of clinical changes in the cornea of rabbits during keratouveitis induction, revealed a decrease in the stability of the tear film, pathological changes in the corneal epithelium and stroma, as well as its anatomical and optical parameters. Comparison of data obtained in the THz scan of the cornea with tears production, optical coherence tomography and confocal microscopy showed their consistency in all observation periods, which allows us to conclude that the developed laboratory setup works and the feasibility of further research to promote the corneal hydration evaluation technology in clinical practice. Acknowledgements: Research was funded by the RSF, grant number 161500255.
|
Korneeva, Y. P., Mikhailov, M. Y., Pershin, Y. P., Manova, N. N., Divochiy, A. V., Vakhtomin, Y. B., et al. (2014). Superconducting single-photon detector made of MoSi film. Supercond. Sci. Technol., 27(9), 095012.
Abstract: We fabricated and characterized nanowire superconducting single-photon detectors made of 4 nm thick amorphous Mox Si1−x films. At 1.7 K the best devices exhibit a detection efficiency (DE) up to 18% at 1.2 $\mu {\rm m}$ wavelength of unpolarized light, a characteristic response time of about 6 ns and timing jitter of 120 ps. The DE was studied in wavelength range from 650 nm to 2500 nm. At wavelengths below 1200 nm these detectors reach their maximum DE limited by photon absorption in the thin MoSi film.
|
Tretyakov, I., Shurakov, A., Perepelitsa, A., Kaurova, N., Svyatodukh, S., Zilberley, T., et al. (2019). Room temperature silicon detector for IR range coated with Ag2S quantum dots. Phys. Status Solidi RRL, 13(9), 1900187–(1–6).
Abstract: For decades, silicon has been the chief technological semiconducting material of modern microelectronics and has a strong influence on all aspects of the society. Applications of Si-based optoelectronic devices are limited to the visible and near infrared (IR) ranges. For photons with an energy less than 1.12 eV, silicon is almost transparent. The expansion of the Si absorption to shorter wavelengths of the IR range is of considerable interest for optoelectronic applications. By creating impurity states in Si, it is possible to cause sub-bandgap photon absorption. Herein, an elegant and effective technology of extending the photo-response of Si toward the IR range is presented. This approach is based on the use of Ag 2 S quantum dots (QDs) planted on the surface of Si to create impurity states in the Si bandgap. The specific sensitivity of the room temperature zero-bias Si_Ag 2 Sp detector is 10 11 cm Hz W 1 at 1.55 μm. Given the variety of available QDs and the ease of extending the photo-response of Si toward the IR range, these findings open a path toward future studies and development of Si detectors for technological applications. The current research at the interface of physics and chemistry is also of fundamental importance to the development of Si optoelectronics.
|
Iomdina, E. N., Goltsman, G. N., Seliverstov, S. V., Sianosyan, A. A., Teplyakova, K. O., & Rusova, A. A. (2016). Study of transmittance and reflectance spectra of the cornea and the sclera in the THz frequency range. J. Biomed. Opt., 21(9), 97002 (1 to 5).
Abstract: An adequate water balance (hydration extent) is one of the basic factors of normal eye function, including its external shells: the cornea and the sclera. Adequate control of corneal and scleral hydration is very important for early diagnosis of a variety of eye diseases, stating indications for and contraindications against keratorefractive surgeries and the choice of contact lens correction solutions. THz systems of creating images in reflected beams are likely to become ideal instruments of noninvasive control of corneal and scleral hydration degrees. This paper reports on the results of a study involving transmittance and reflectance spectra for the cornea and the sclera of rabbit and human eyes, as well as those of the rabbit eye, in the frequency range of 0.13 to 0.32 THz. The dependence of the reflectance coefficient of these tissues on water mass percentage content was determined. The experiments were performed on three corneas, three rabbit scleras, two rabbit eyes, and three human scleras. The preliminary results demonstrate that the proposed technique, based on the use of a continuous THz radiation, may be utilized to create a device for noninvasive control of corneal and scleral hydration, which has clear potential of broad practical application.
Keywords: BWO, IMPATT diode, Schottky diode, medicine, animals, cornea, physiology, humans, rabbits, sclera diagnostic imaging, physiology
|
Morozov, D. V., Smirnov, K. V., Smirnov, A. V., Lyakhov, V. A., & Goltsman, G. N. (2005). A millimeter-submillimeter phonon-cooled hot-electron bolometer mixer based on two-dimensional electron gas in an AlGaAs/GaAs heterostructure. Semicond., 39(9), 1082–1086.
Abstract: Experimental results obtained by studying the main characteristics of a millimeter-submillimeter wave mixer based on the hot-electron effect in a two-dimensional electron gas in a AlGaAs/GaAs heterostructure with a phonon-scattering cooling mechanism for charge carriers are reported. The gain bandwidth of the mixer is 4 GHz, the internal conversion losses are 13 dB, and the optimum local-oscillator power is 0.5 μW (for a mixer area of 1 μm2). It is shown that a millimeter-submillimeter-wave receiver with a noise temperature of 1900 K can be developed on the basis of a AlGaAs/GaAs mixer. This mixer also appears to be promising for use in array receiver elements.
|
Tretyakov, I. V., Finkel, M. I., Ryabchun, S. A., Kardakova, A. I., Seliverstov, S. V., Petrenko, D. V., et al. (2014). Hot-electron bolometer mixers with in situ contacts. Radiophys. Quant. Electron., 56(8-9), 591–598.
Abstract: We report on the latest achievements in the development of superconducting hot-electron bolometer (HEB) mixers for terahertz superheterodyne receivers. We consider application ranges of such receivers and requirements for the basic characteristics of the mixers. Main features of the mixers, such as noise temperature, gain bandwidth, noise bandwidth, and required local-oscillator power, have been improved significantly over the past few years due to intense research work, both in terms of the element fabrication quality and in terms of understanding of the physics of the processes occurring in the HEB mixers. Contacts between the superconducting bridge and the planar antenna play a key role in the mixer operation. Improvement of the quality of the contacts leads simultaneously to a decrease in the noise temperature and an increase in the gain bandwidth of a mixer.
|
Zhang, W., Miao, W., Zhong, J. Q., Shi, S. C., Hayton, D. J., Vercruyssen, N., et al. (2014). Temperature dependence of the receiver noise temperature and IF bandwidth of superconducting hot electron bolometer mixers. Supercond. Sci. Technol., 27(8), 085013 (1 to 5).
Abstract: In this paper we study the temperature dependence of the receiver noise temperature and IF noise bandwidth of superconducting hot electron bolometer (HEB) mixers. Three superconducting NbN HEB devices of different transition temperatures (Tc) are measured at 0.85 THz and 1.4 THz at different bath temperatures (Tbath) between 4 K and 9 K. Measurement results demonstrate that the receiver noise temperature of superconducting NbN HEB devices is nearly constant for Tbath/Tc, less than 0.8, which is consistent with the simulation based on a distributed hot-spot model. In addition, the IF noise bandwidth appears independent of Tbath/Tc, indicating the dominance of phonon cooling in the investigated HEB devices.
|
Lobanov, Y. V., Vakhtomin, Y. B., Pentin, I. V., Rosental, V. A., Smirnov, K. V., Goltsman, G. N., et al. (2021). Time-resolved measurements of light–current characteristic and mode competition in pulsed THz quantum cascade laser. Optical Engineering, 60(8), 1–8.
Abstract: Quantum cascade lasers (QCL) are widely adopted as prominent and easy-to-use solid-state sources of terahertz radiation. Yet some applications require generation and detection of very sharp and narrow terahertz-range pulses with a specific spectral composition. We have studied time-resolved light-current (L–I) characteristics of multimode THz QCL operated with a fast ramp of the injection current. Detection of THz pulses was carried out using an NbN superconducting hot-electron bolometer with the time constant of the order of 1 ns while the laser bias current was swept during a single driving pulse. A nonmonotonic behavior of the L–I characteristic with several visually separated subpeaks was found. This behavior is associated with the mode competition in THz QCL cavity, which we confirm by L–I measurements with use of an external Fabry–Perot interferometer for a discrete mode selection. We also have demonstrated the possibility to control the L–I shape with suppression of one of the subpeaks by simply adjusting the off-axis parabolic mirror for optimal optical alignment for one of the laser modes. The developed technique paves the way for rapid characterization of pulsed THz QCLs for further studies of the possibilities of using this approach in remote sensing.
|
Voevodin, E. I., Gershenzon, E. M., Goltsman, G. N., & Ptitsina, N. G. (1989). Energy-spectrum of shallow acceptors in Ge deformed strongly by a uniaxial pressure. Sov. Phys. and Technics of Semiconductors, 23(8), 843–846.
Abstract: Проведены исследования спектров фототермической ионизации мелких акцепторов (В, Аl) в Ge, предельно сжатом вдоль кристаллографической оси [100]. Из данных измерений с учетом теории построен энергетический спектр примесей. Показано, что энергии большого числа уровней четных и нечетных состояний хорошо соответствуют расчету, выполненному для примесей в анизотропном полупроводнике с параметром анизотропии γ=m∗⊥/m∗∥>1.
|
Gershenzon, E. M., Goltsman, G., Orlova, S., Ptitsina, N., & Gurvich, Y. (1971). Germanium hot-electron narrow-band detector. Sov. Radio Engineering And Electronic Physics, 16(8), 1346.
|
Elezov, M. S., Semenov, A. V., An, P. P., Tarkhov, M. A., Goltsman, G. N., Kardakova, A. I., et al. (2013). Investigating the detection regimes of a superconducting single-photon detector. J. Opt. Technol., 80(7), 435.
Abstract: The detection regimes of a superconducting single-photon detector have been investigated. A technique is proposed for determining the regions in which “pure regimes” predominate. Based on experimental data, the dependences of the internal quantum efficiency on the bias current are determined in the one-, two-, and three-photon detection regimes.
|
Antipov, S., Trifonov, A., Krause, S., Meledin, D., Kaurova, N., Rudzinski, M., et al. (2019). Improved bandwidth of a 2 THz hot-electron bolometer heterodyne mixer fabricated on sapphire with a GaN buffer layer. Supercond. Sci. Technol., 32(7), 075003.
Abstract: We report on the signal-to-noise and gain bandwidth of a niobium nitride (NbN) hot-electron bolometer (HEB) mixer at 2 THz fabricated on a sapphire substrate with a GaN buffer layer. Two mixers with different DC properties and geometrical dimensions were studied and they demonstrated very close bandwidth performance. The signal-to-noise bandwidth is increased to 8 GHz in comparison to the previous results, obtained without a buffer-layer. The data were taken in a quasi-optical system with the use of the signal-to-noise method, which is close to the signal levels used in actual astrophysical observations. We find an increase of the gain bandwidth to 5 GHz. The results indicate that prior results obtained on a substrate of crystalline GaN can also be obtained on a conventional sapphire substrate with a few micron MOCVD-deposited GaN buffer-layer.
|
Korneev, A., Korneeva, Y., Florya, I., Semenov, A., & Goltsman, G. (2018). Photon switching statistics in multistrip superconducting single-photon detectors. IEEE Trans. Appl. Supercond., 28(7), 1–4.
Abstract: We study photon count statistics in superconducting single-photon detectors consisting of up to 70 narrow superconducting strips connected in parallel. Using interarrival time analysis, we demonstrate that our samples are operated in the “arm-trigger” regime and require up to seven subsequently absorbed photons to form a resistive state in the whole sample. We also performed numerical simulation of the light and dark count rates versus detector bias current, which are in good agreement with the experimental results.
|
Seliverstov, S. V., Anfertyev, V. A., Tretyakov, I. V., Ozheredov, I. A., Solyankin, P. M., Revin, L. S., et al. (2017). Terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. Radiophys. Quant. Electron., 60(7), 518–524.
Abstract: We study characteristics of the laboratory prototype of a terahertz heterodyne receiver with an electron-heating mixer and a heterodyne based on the quantum-cascade laser. The results obtained demonstrate the possibility to use this receiver as a basis for creation of a high-sensitivity terahertz spectrometer, which can be used in many basic and practical applications. A significant advantage of this receiver will be the possibility of placing the mixer and heterodyne in the same cryostat, which will reduce the device dimensions considerably. The obtained experimental results are analyzed, and methods of optimizing the parameters of the receiver are proposed.
|
Gershenzon, Y. M., Goltsman, G. N., Yelantyev, A. I., Petrova, Y. B., Ptitsina, N. G., & Filatov, V. S. (1987). Lecture demonstrations of properties of superconductors and liquid helium. USSR Rept Phys. Math. JPRS UPM, 24(7), 51.
Abstract: New demonstrations for low temperature physics courses are described. Two transparent Dewar vacuum flasks fitting one inside the other with the external flask for nitrogen and the internal flask for helium are used. The helium temperature can be regulated in the 4.2 to 1.6 K range and the effects of reducing helium to the superfluid state at 2.17 K can be shown: boiling abruptly stops and superfluid flow appears. In order to show the electric and magnetic characteristics of superconductivity, a superconducting NbTi solenoid containing nonsuperconducting wire and germanium and superconducting Nb materials with different critical temperatures is placed in the helium refrigerant vessel. The fall of the resistance at the critical temperatures can be shown. In order to show magnetic field and superconductive current flow properties a shunt of superconductive material is connected in parallel to the coil and is enclosed in a teflon container with a heater which can vary its temperature. When it is heated and not superconductive, magnetic field effects can be demonstrated and when it is unheated and superconducting a continuous current can be demonstrated.
|